{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T11:04:31Z","timestamp":1762340671055},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014,1]]},"DOI":"10.1097\/mat.0000000000000012","type":"journal-article","created":{"date-parts":[[2013,12,9]],"date-time":"2013-12-09T09:23:06Z","timestamp":1386580986000},"page":"9-14","source":"Crossref","is-referenced-by-count":30,"title":["The Role of Medical Management for Acute Intravascular Hemolysis in Patients Supported on Axial Flow LVAD"],"prefix":"10.1097","volume":"60","author":[{"given":"Tal","family":"Hasin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Salil","family":"Deo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph J.","family":"Maleszewski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yan","family":"Topilsky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brooks S.","family":"Edwards","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naveen L.","family":"Pereira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John M.","family":"Stulak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lyle","family":"Joyce","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard","family":"Daly","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sudhir S.","family":"Kushwaha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Soon J.","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-3-20210129","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group. Long-term use of a left ventricular assist device for end-stage heart failure.","volume":"345","author":"Rose","year":"2001","journal-title":"N Engl J Med"},{"key":"R2-3-20210129","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","article-title":"HeartMate II Investigators. Advanced heart failure treated with continuous-flow left ventricular assist device.","volume":"361","author":"Slaughter","year":"2009","journal-title":"N Engl J Med"},{"key":"R3-3-20210129","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.healun.2010.12.001","article-title":"Third INTERMACS Annual Report: The evolution of destination therapy in the United States.","volume":"30","author":"Kirklin","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"R5-3-20210129","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jtcvs.2008.07.032","article-title":"Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices.","volume":"137","author":"Crow","year":"2009","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R6-3-20210129","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.jacc.2009.03.055","article-title":"HeartMate II Investigators. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device.","volume":"54","author":"Pagani","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"R7-3-20210129","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.jtcvs.2007.12.077","article-title":"Low thromboembolic risk for patients with the Heartmate II left ventricular assist device.","volume":"136","author":"John","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R8-3-20210129","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1510\/icvts.2010.240747","article-title":"Discontinuation of antithrombotic therapy for a year or more in patients with continuous-flow left ventricular assist devices.","volume":"11","author":"Pereira","year":"2010","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"R9-3-20210129","doi-asserted-by":"crossref","first-page":"e7","DOI":"10.1016\/j.jtcvs.2009.09.046","article-title":"Early thrombus in a HeartMate II left ventricular assist device: A potential cause of hemolysis and diagnostic dilemma.","volume":"140","author":"Bhamidipati","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R10-3-20210129","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1161\/CIRCIMAGING.111.965335","article-title":"Echocardiographic variables after left ventricular assist device implantation associated with adverse outcome.","volume":"4","author":"Topilsky","year":"2011","journal-title":"Circ Cardiovasc Imaging"},{"key":"R11-3-20210129","doi-asserted-by":"crossref","first-page":"1764","DOI":"10.1016\/j.jacc.2012.07.052","article-title":"Development of a novel echocardiography ramp test for speed optimization and diagnosis of device thrombosis in continuous-flow left ventricular assist devices: The Columbia ramp study.","volume":"60","author":"Uriel","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"R12-3-20210129","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.jtcvs.2010.11.022","article-title":"Management of HeartWare left ventricular assist device thrombosis using intracavitary thrombolytics.","volume":"142","author":"Kiernan","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R15-3-20210129","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.hlc.2007.04.012","article-title":"Successful treatment of ventricular assist device associated ventricular thrombus with systemic tenecteplase.","volume":"17","author":"Hayes","year":"2008","journal-title":"Heart Lung Circ"},{"key":"R16-3-20210129","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.ejcts.2009.04.015","article-title":"Haemolysis in patients with ventricular assist devices: Major differences between systems.","volume":"36","author":"Heilmann","year":"2009","journal-title":"Eur J Cardiothorac Surg"},{"key":"R17-3-20210129","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/j.healun.2009.05.018","article-title":"Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: Analysis of outpatient anti-coagulation.","volume":"28","author":"Boyle","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"R18-3-20210129","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1111\/j.1525-1594.2007.00391.x","article-title":"The effect of surface roughness on activation of the coagulation system and platelet adhesion in rotary blood pumps.","volume":"31","author":"Linneweber","year":"2007","journal-title":"Artif Organs"},{"key":"R19-3-20210129","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1111\/j.1525-1594.2010.01089.x","article-title":"Consequences arising from elevated surface temperatures on human blood.","volume":"34","author":"Hamilton","year":"2010","journal-title":"Artif Organs"},{"key":"R20-3-20210129","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1016\/j.athoracsur.2009.06.095","article-title":"Activation of endothelial and coagulation systems in left ventricular assist device recipients.","volume":"88","author":"John","year":"2009","journal-title":"Ann Thorac Surg"},{"key":"R21-3-20210129","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/MAT.0b013e318161a987","article-title":"Fibrinolytic activation during long-term support with the HeartMate II left ventricular assist device.","volume":"54","author":"Slaughter","year":"2008","journal-title":"ASAIO J"},{"key":"R22-3-20210129","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1038\/ncpcardio1441","article-title":"Prospective, observational study of antiplatelet and coagulation biomarkers as predictors of thromboembolic events after implantation of ventricular assist devices.","volume":"6","author":"Majeed","year":"2009","journal-title":"Nat Clin Pract Cardiovasc Med"},{"key":"R23-3-20210129","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.jtcvs.2011.03.029","article-title":"Assessment of long-term anticoagulation in patients with a continuous-flow left-ventricular assist device: A pilot study.","volume":"142","author":"Jennings","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R25-3-20210129","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1111\/j.1525-1594.2005.29050.x","article-title":"Platelet activation markers in patients with heart assist device.","volume":"29","author":"Dewald","year":"2005","journal-title":"Artif Organs"},{"key":"R26-3-20210129","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1016\/j.healun.2006.03.013","article-title":"An alternative treatment strategy for pump thrombus in the DeBakey VAD Child: Use of clopidogrel as a thrombolytic agent.","volume":"25","author":"Studer","year":"2006","journal-title":"J Heart Lung Transplant"},{"key":"R27-3-20210129","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1016\/j.healun.2008.05.015","article-title":"Successful treatment of rotary pump thrombus with the glycoprotein IIbIIIa inhibitor tirofiban.","volume":"27","author":"Thomas","year":"2008","journal-title":"J Heart Lung Transplant"},{"key":"R28-3-20210129","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.jtcvs.2007.08.048","article-title":"Thrombus formation in a HeartMate II left ventricular assist device.","volume":"135","author":"Meyer","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R29-3-20210129","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1051\/ject\/200638230","article-title":"Mitigation of device-associated thrombosis and thromboembolism using combinations of heparin and tirofiban.","volume":"38","author":"Meola","year":"2006","journal-title":"J Extra Corpor Technol"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MAT.0000000000000012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,21]],"date-time":"2024-05-21T06:26:01Z","timestamp":1716272761000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00002480-201401000-00003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000000012","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2014,1]]}}}