{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T00:20:18Z","timestamp":1795134018118,"version":"4.10.3"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,7]]},"abstract":"<jats:p>\n                    An implantable hemofilter for the treatment of kidney failure depends critically on the transport characteristics of the membrane and the biocompatibility of the membrane, cartridge, and blood conduits. A novel membrane with slit-shaped pores optimizes the trade-off between permeability and selectivity, enabling implanted therapy. Sustained (3\u20138) day function of an implanted parallel-plate hemofilter with minimal anticoagulation was achieved by considering biocompatibility at the subnanometer scale of chemical interactions and the millimeter scale of blood fluid dynamics. A total of 400 nm-thick polysilicon flat sheet membranes with 5\u20138\u2009nm \u00d7 2 micron slit-shaped pores were surface-modified with polyethylene glycol. Hemofilter cartridge geometries were refined based on computational fluid dynamics models of blood flow. In an uncontrolled pilot study, silicon filters were implanted in six class A dogs. Cartridges were connected to the cardiovascular system by anastamoses to the aorta and inferior vena cava and filtrate was drained to collection pouches positioned in the peritoneum. Pain medicine and acetylsalicylic acid were administered twice daily until the hemofilters were harvested on postoperative days 3 (n = 2), 4 (n = 2), 5 (n = 1), and 8 (n = 1). No hemofilters were thrombosed. Animals treated for 5 and 8 days had microscopic fractures in the silicon nanopore membranes and 20\u201350\u2009ml of transudative (albumin sieving coefficient\n                    <jats:italic toggle=\"yes\">\u03b8<\/jats:italic>\n                    <jats:sub>alb<\/jats:sub>\n                    ~ 0.5 \u2013 0.7) fluid in the collection pouches at the time of explant. Shorter experimental durations (3\u20134 days) resulted in filtration volumes similar to predictions based on mean arterial pressures and membrane hydraulic permeability and (\n                    <jats:italic toggle=\"yes\">\u03b8<\/jats:italic>\n                    <jats:sub>alb<\/jats:sub>\n                    ~ 0.2 \u2013 0.3), similar to preimplantation measurements. In conclusion, a detailed mechanistic and materials science attention to blood\u2013material interactions allows implanted hemofilters to resist thrombosis. Additional testing is needed to determine optimal membrane characteristics and identify limiting factors in long-term implantation.\n                  <\/jats:p>","DOI":"10.1097\/mat.0000000000000367","type":"journal-article","created":{"date-parts":[[2016,3,19]],"date-time":"2016-03-19T12:45:46Z","timestamp":1458391546000},"page":"491-495","source":"Crossref","is-referenced-by-count":44,"title":["First Implantation of Silicon Nanopore Membrane Hemofilters"],"prefix":"10.1097","volume":"62","author":[{"given":"Clark","family":"Kensinger","sequence":"first","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seth","family":"Karp","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rishi","family":"Kant","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin W.","family":"Chui","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth","family":"Goldman","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Torin","family":"Yeager","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward R.","family":"Gould","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amanda","family":"Buck","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David C.","family":"Laneve","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph J.","family":"Groszek","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuvo","family":"Roy","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William H.","family":"Fissell","sequence":"additional","affiliation":[{"name":"Biomedical Engineering, Vanderbilt University, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230821","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1681\/ASN.2007080895","article-title":"Efficacy and safety of renal tubule cell therapy for acute renal failure.","volume":"19","author":"Tumlin","year":"2008","journal-title":"J Am Soc Nephrol"},{"key":"R2-20230821","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1177\/039139880102401005","article-title":"Nanoscale modulation of the pore dimensions, size distribution and structure of a new polysulfone-based high-flux dialysis membrane.","volume":"24","author":"Ronco","year":"2001","journal-title":"Int J Artif Organs"},{"key":"R3-20230821","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1177\/039139880402700102","article-title":"Nanotechnology and dialysis.","volume":"27","author":"Nissenson","year":"2004","journal-title":"Int J Artif Organs"},{"key":"R4-20230821","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.memsci.2009.12.003","article-title":"Permeability-selectivity analysis for ultrafiltration: Effect of pore geometry.","volume":"349","author":"Kanani","year":"2010","journal-title":"J Memb Sci"},{"key":"R5-20230821","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1023\/A:1009903215959","article-title":"Nanopore technology for biomedical applications.","volume":"2","author":"Desai","year":"1999","journal-title":"Biomed Microdevices"},{"key":"R6-20230821","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1007\/s10439-007-9257-2","article-title":"DPIV prediction of flow induced platelet activation-comparison to numerical predictions.","volume":"35","author":"Raz","year":"2007","journal-title":"Ann Biomed Eng"},{"key":"R7-20230821","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1007\/s10439-011-0256-y","article-title":"Hemocompatibility of silicon-based substrates for biomedical implant applications.","volume":"39","author":"Muthusubramaniam","year":"2011","journal-title":"Ann Biomed Eng"},{"key":"R8-20230821","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1007\/s10439-010-9904-x","article-title":"Particle-based methods for multiscale modeling of blood flow in the circulation and in devices: Challenges and future directions. Sixth international bio-fluid mechanics symposium and workshop March 28\u201330, 2008 Pasadena, California.","volume":"38","author":"Yamaguchi","year":"2010","journal-title":"Ann Biomed Eng"},{"key":"R9-20230821","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.memsci.2008.09.039","article-title":"High-performance silicon nanopore hemofiltration membranes.","volume":"326","author":"Fissell","year":"2009","journal-title":"J Memb Sci"},{"key":"R10-20230821","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1021\/la000609d","article-title":"Characterization of ultrathin poly(ethylene glycol) monolayers on silicon substrates.","volume":"17","author":"Papra","year":"2001","journal-title":"Langmuir"},{"key":"R11-20230821","doi-asserted-by":"crossref","first-page":"F84","DOI":"10.1152\/ajprenal.2000.279.1.F84","article-title":"Glomerular size and charge selectivity in the rat as revealed by FITC-ficoll and albumin.","volume":"279","author":"Ohlson","year":"2000","journal-title":"Am J Physiol Renal Physiol"},{"key":"R12-20230821","doi-asserted-by":"crossref","first-page":"F1209","DOI":"10.1152\/ajprenal.00097.2007","article-title":"Ficoll is not a rigid sphere.","volume":"293","author":"Fissell","year":"2007","journal-title":"Am J Physiol Renal Physiol"},{"key":"R13-20230821","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1097\/MAT.0b013e3181d98cf8","article-title":"Silicon induces minimal thromboinflammatory response during 28-day intravascular implant testing.","volume":"56","author":"Melvin","year":"2010","journal-title":"ASAIO J"},{"key":"R14-20230821","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1163\/092050609X12578498982998","article-title":"Anti-biofouling Sulfobetaine Polymer Thin Films on Silicon and Silicon Nanopore Membranes.","volume":"22","author":"Li","year":"2011","journal-title":"J Biomater Sci Polym Ed"},{"key":"R15-20230821","doi-asserted-by":"crossref","first-page":"561","DOI":"10.2215\/CJN.05540610","article-title":"Peritoneal albumin and protein losses do not predict outcome in peritoneal dialysis patients.","volume":"6","author":"Balafa","year":"2011","journal-title":"Clin J Am Soc Nephrol"},{"key":"R16-20230821","first-page":"358A","article-title":"Enhanced \u03b22-microglobulin clearance by silicon nanopore membranes.","volume":"21","author":"Fissell","year":"2010","journal-title":"JASN"},{"key":"R17-20230821","doi-asserted-by":"crossref","first-page":"4087","DOI":"10.1023\/A:1026317303377","article-title":"Probabilistic weibull behavior and mechanical properties of MEMS brittle materials.","volume":"38","author":"Jadaan","year":"2003","journal-title":"J Mater Sci"},{"key":"R18-20230821","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1109\/JMEMS.2005.851862","article-title":"Fracture strength of silicon carbide microspecimens.","volume":"14","author":"Sharpe","year":"2005","journal-title":"J Microelectromech Sys"},{"key":"R19-20230821","doi-asserted-by":"crossref","first-page":"471","DOI":"10.2165\/00003088-199528060-00005","article-title":"Novel delivery of pancreatic islet cells to treat insulin-dependent diabetes mellitus.","volume":"28","author":"Maki","year":"1995","journal-title":"Clin Pharmacokinet"},{"key":"R20-20230821","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1177\/039139880703001209","article-title":"Comparison of middle-molecule clearance between convective control double high-flux hemodiafiltration and on-line hemodiafiltration.","volume":"30","author":"Tiranathanagul","year":"2007","journal-title":"Int J Artif Organs"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00002480-201607000-00023","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T21:32:34Z","timestamp":1692653554000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00002480-201607000-00023"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000000367","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2016,7]]}}}