{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T17:30:03Z","timestamp":1788802203759,"version":"build-2803163510"},"reference-count":77,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,5]]},"abstract":"<jats:p>There is increasing evidence for successful management of end-stage heart failure with continuous-flow left ventricular assist device (CF-LVAD) technology. However, passive flow adjustment at fixed CF-LVAD speed is susceptible to flow balancing issues as well as adverse hemodynamic effects relating to the diminished arterial pulse pressure and flow. With current therapy, flow cannot be adjusted with changes in venous return, which can vary significantly with volume status. This limits the performance and safety of CF-LVAD. Active flow adjustment strategies have been proposed to improve the synchrony between the pump and the native cardiovascular system, mimicking the Frank\u2013Starling mechanism of the heart. These flow adjustment strategies include modulation by CF-LVAD pump speed by synchrony and maintenance of constant flow or constant pressure head, or a combination of these variables. However, none of these adjustment strategies have evolved sufficiently to gain widespread attention. Herein we review the current challenges and future directions of CF-LVAD therapy and sensor technology focusing on the development of a physiologic, long-term active flow adjustment strategy for CF-LVADs.<\/jats:p>","DOI":"10.1097\/mat.0000000000000477","type":"journal-article","created":{"date-parts":[[2016,11,18]],"date-time":"2016-11-18T03:20:11Z","timestamp":1479439211000},"page":"241-250","source":"Crossref","is-referenced-by-count":45,"title":["Clinical Implications of Physiologic Flow Adjustment in Continuous-Flow Left Ventricular Assist Devices"],"prefix":"10.1097","volume":"63","author":[{"given":"Vakhtang","family":"Tchantchaleishvili","sequence":"first","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, University of Louisville, Louisville, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica G. Y.","family":"Luc","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, University of Louisville, Louisville, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caitlin M.","family":"Cohan","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, University of Louisville, Louisville, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Phan","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, University of Louisville, Louisville, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laila","family":"H\u00fcbbert","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, University of Louisville, Louisville, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven W.","family":"Day","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, University of Louisville, Louisville, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H. Todd","family":"Massey","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, University of Louisville, Louisville, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230821","first-page":"e2","article-title":"Heart disease and stroke statistics\u20132012 update: A report from the American Heart Association.","volume":"125","author":"Roger","year":"2012","journal-title":"Circulation"},{"key":"R2-20230821","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.healun.2010.12.001","article-title":"Third INTERMACS Annual Report: the evolution of destination therapy in the United States.","volume":"30","author":"Kirklin","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"R3-20230821","doi-asserted-by":"crossref","first-page":"E47","DOI":"10.1111\/j.1525-1594.2010.01168.x","article-title":"Response of rotary blood pumps to changes in preload and afterload at a fixed speed setting are unphysiological when compared with the natural heart.","volume":"35","author":"Salamonsen","year":"2011","journal-title":"Artif Organs"},{"key":"R4-20230821","doi-asserted-by":"crossref","first-page":"1878","DOI":"10.1016\/j.healun.2005.02.004","article-title":"Development of a reliable automatic speed control system for rotary blood pumps.","volume":"24","author":"Vollkron","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"R5-20230821","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1097\/MAT.0b013e31817b5b0e","article-title":"Reliable suction detection for patients with rotary blood pumps.","volume":"54","author":"Mason","year":"2008","journal-title":"ASAIO J"},{"key":"R7-20230821","first-page":"181","article-title":"Who discovered the Frank-Starling mechanism?","volume":"17","author":"Zimmer","year":"2002","journal-title":"News Physiol Sci"},{"key":"R8-20230821","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1111\/j.1525-1594.2010.01092.x","article-title":"Fully autonomous preload-sensitive control of implantable rotary blood pumps.","volume":"34","author":"Arndt","year":"2010","journal-title":"Artif Organs"},{"key":"R9-20230821","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/34\/1\/R1","article-title":"Developments in control systems for rotary left ventricular assist devices for heart failure patients: A review.","volume":"34","author":"AlOmari","year":"2013","journal-title":"Physiol Meas"},{"key":"R10-20230821","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.jchf.2014.11.006","article-title":"Echocardiographic Ramp test for continuous-flow left ventricular assist devices: Do loading conditions matter?","volume":"3","author":"Adatya","year":"2015","journal-title":"JACC Heart Fail"},{"key":"R11-20230821","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1016\/j.healun.2009.03.011","article-title":"Incidence of ventricular arrhythmias in patients on long-term support with a continuous-flow assist device (HeartMate II).","volume":"28","author":"Andersen","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"R12-20230821","first-page":"497","article-title":"Intelligent control design for heart assist devices.","author":"Boston","year":"1998"},{"key":"R13-20230821","first-page":"402","article-title":"Detection and avoiding ventricular suction of ventricular assist devices.","volume":"1","author":"Tanaka","year":"2005","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"R14-20230821","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1111\/j.1525-1594.2004.00011.x","article-title":"Development of a suction detection system for axial blood pumps.","volume":"28","author":"Vollkron","year":"2004","journal-title":"Artif Organs"},{"key":"R15-20230821","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1111\/j.1525-1594.2007.00420.x","article-title":"Suction due to left ventricular assist: implications for device control and management.","volume":"31","author":"Reesink","year":"2007","journal-title":"Artif Organs"},{"key":"R16-20230821","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1111\/aor.12225","article-title":"A physiological controller for turbodynamic ventricular assist devices based on a measurement of the left ventricular volume.","volume":"38","author":"Ochsner","year":"2014","journal-title":"Artif Organs"},{"key":"R17-20230821","first-page":"3823","article-title":"Achieving physiologic perfusion with ventricular assist devices: Comparison of control strategies,","volume":"2005","author":"Giridharan","journal-title":"in Proceedings of the 2005, American Control Conference"},{"key":"R18-20230821","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.healun.2012.10.001","article-title":"Axial and centrifugal continuous-flow rotary pumps: A translation from pump mechanics to clinical practice.","volume":"32","author":"Moazami","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R19-20230821","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1161\/CIRCHEARTFAILURE.114.002000","article-title":"Blood pressure and adverse events during continuous flow left ventricular assist device support.","volume":"8","author":"Saeed","year":"2015","journal-title":"Circ Heart Fail"},{"key":"R20-20230821","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1097\/MAT.0000000000000262","article-title":"Feasibility of pump speed modulation for restoring vascular pulsatility with rotary blood pumps.","volume":"61","author":"Ising","year":"2015","journal-title":"ASAIO J"},{"key":"R21-20230821","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1016\/j.healun.2009.12.017","article-title":"Optimization of axial-pump pressure sensitivity for a continuous-flow total artificial heart.","volume":"29","author":"Frazier","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R23-20230821","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1109\/87.918900","article-title":"A sensorless approach to control of a turbo dynamic left ventricular assist system.","volume":"9","author":"Seongjin Choi","year":"2001","journal-title":"IEEE Trans Control Syst Technol"},{"key":"R24-20230821","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1016\/j.healun.2015.03.001","article-title":"First implantation in man of a new magnetically levitated left ventricular assist device (HeartMate III).","volume":"34","author":"Schmitto","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"R25-20230821","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1111\/j.1525-1594.2006.00276.x","article-title":"In vivo assessment of a rotary left ventricular assist device-induced artificial pulse in the proximal and distal aorta.","volume":"30","author":"Bourque","year":"2006","journal-title":"Artif Organs"},{"key":"R26-20230821","doi-asserted-by":"crossref","first-page":"S53","DOI":"10.1016\/j.healun.2013.01.943","article-title":"a novel algorithm to promote native aortic valve function using the next generation heartware MVAD.","volume":"32","author":"Kapur","year":"2013","journal-title":"J Hear Lung Transplant"},{"key":"R27-20230821","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/imi.0000000000000155","article-title":"Design concepts and preclinical results of a miniaturized HeartWare platform: the MVAD system.","volume":"10","author":"Cheung","year":"2015","journal-title":"Innovations (Phila)"},{"key":"R28-20230821","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1007\/s13239-011-0042-x","article-title":"Flow modulation algorithms for continuous flow left ventricular assist devices to increase vascular pulsatility: A computer simulation study.","volume":"2","author":"Ising","year":"2011","journal-title":"Cardiovasc Eng Technol"},{"key":"R29-20230821","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.healun.2014.09.017","article-title":"Rotary pump speed modulation for generating pulsatile flow and phasic left ventricular volume unloading in a bovine model of chronic ischemic heart failure.","volume":"34","author":"Soucy","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"R30-20230821","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1097\/00002480-200009000-00018","article-title":"Relationship of blood pressure and pump flow in an implantable centrifugal blood pump during hypertension.","volume":"46","author":"Akimoto","year":"2000","journal-title":"ASAIO J"},{"key":"R31-20230821","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1093\/ejcts\/ezs299","article-title":"Asymmetric speed modulation of a rotary blood pump affects ventricular unloading.","volume":"43","author":"Pirbodaghi","year":"2013","journal-title":"Eur J Cardiothorac Surg"},{"key":"R32-20230821","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1111\/j.1525-1594.1992.tb00293.x","article-title":"Noninvasive monitoring of rotary blood pumps: Necessity, possibilities, and limitations.","volume":"16","author":"Schima","year":"1992","journal-title":"Artif Organs"},{"key":"R33-20230821","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1046\/j.1525-1594.2000.06652.x","article-title":"The history of continuous-flow blood pumps.","volume":"24","author":"Olsen","year":"2000","journal-title":"Artif Organs"},{"key":"R34-20230821","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1111\/j.1525-1594.2012.01457.x","article-title":"Theoretical foundations of a Starling-like controller for rotary blood pumps.","volume":"36","author":"Salamonsen","year":"2012","journal-title":"Artif Organs"},{"key":"R35-20230821","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.pbiomolbio.2008.02.002","article-title":"Impact of left ventricular assist device (LVAD) support on the cardiac reverse remodeling process.","volume":"97","author":"Klotz","year":"2008","journal-title":"Prog Biophys Mol Biol"},{"key":"R36-20230821","doi-asserted-by":"crossref","first-page":"733","DOI":"10.12659\/MSM.890824","article-title":"Hemodynamic effects of various support modes of continuous flow LVADs on the cardiovascular system: A numerical study.","volume":"20","author":"Song","year":"2014","journal-title":"Med Sci Monit"},{"key":"R37-20230821","first-page":"1335","article-title":"Frank-starling control of a left ventricular assist device.","volume":"2011","author":"Stevens","year":"2011","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"R38-20230821","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1007\/BF01907971","article-title":"Ventricular pressure-volume relations as the primary basis for evaluation of cardiac mechanics. Return to Frank\u2019s diagram.","volume":"84","author":"Jacob","year":"1989","journal-title":"Basic Res Cardiol"},{"key":"R39-20230821","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1161\/01.CIR.53.3.443","article-title":"Asymptotic slope of log pressure vs log volume as an approximate index of the diastolic elastic properties of the myocardium in man.","volume":"53","author":"Laird","year":"1976","journal-title":"Circulation"},{"key":"R40-20230821","doi-asserted-by":"crossref","first-page":"H403","DOI":"10.1152\/ajpheart.01240.2005","article-title":"Single-beat estimation of end-diastolic pressure-volume relationship: A novel method with potential for noninvasive application.","volume":"291","author":"Klotz","year":"2006","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"R41-20230821","doi-asserted-by":"crossref","first-page":"2713","DOI":"10.1161\/01.CIR.102.22.2713","article-title":"Chronic unloading by left ventricular assist device reverses contractile dysfunction and alters gene expression in end-stage heart failure.","volume":"102","author":"Heerdt","year":"2000","journal-title":"Circulation"},{"key":"R42-20230821","doi-asserted-by":"crossref","first-page":"2717","DOI":"10.1161\/01.CIR.91.11.2717","article-title":"Reversal of chronic ventricular dilation in patients with end-stage cardiomyopathy by prolonged mechanical unloading.","volume":"91","author":"Levin","year":"1995","journal-title":"Circulation"},{"key":"R43-20230821","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1046\/j.1525-1594.1999.06386.x","article-title":"Motor feedback physiological control for a continuous flow ventricular assist device.","volume":"23","author":"Waters","year":"1999","journal-title":"Artif Organs"},{"key":"R44-20230821","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1046\/j.1525-1594.2002.07126.x","article-title":"Physiologic control algorithms for rotary blood pumps using pressure sensor input.","volume":"26","author":"Bullister","year":"2002","journal-title":"Artif Organs"},{"key":"R45-20230821","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1111\/j.1525-1594.2006.00217.x","article-title":"Physiological control of blood pumps using intrinsic pump parameters: A computer simulation study.","volume":"30","author":"Giridharan","year":"2006","journal-title":"Artif Organs"},{"key":"R46-20230821","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1038\/sj.cdd.4402273","article-title":"Signaling pathways from membrane lipid rafts to JNK1 activation in reactive nitrogen species-induced non-apoptotic cell death.","volume":"15","author":"Wu","year":"2008","journal-title":"Cell Death Differ"},{"key":"R47-20230821","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1097\/MAT.0b013e3181aa2554","article-title":"Adaptive physiological speed\/flow control of rotary blood pumps in permanent implantation using intrinsic pump parameters.","volume":"55","author":"Wu","year":"2009","journal-title":"ASAIO J"},{"key":"R48-20230821","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1111\/j.1525-1594.2004.07381.x","article-title":"A bridge from short-term to long-term left ventricular assist device\u2013experimental verification of a physiological controller.","volume":"28","author":"Wu","year":"2004","journal-title":"Artif Organs"},{"key":"R49-20230821","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1046\/j.1525-1594.2003.00032.x","article-title":"An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse.","volume":"27","author":"Wu","year":"2003","journal-title":"Artif Organs"},{"key":"R50-20230821","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1111\/j.1525-1594.2008.00628.x","article-title":"Physiological control of a rotary blood pump with selectable therapeutic options: Control of pulsatility gradient.","volume":"32","author":"Arndt","year":"2008","journal-title":"Artif Organs"},{"key":"R51-20230821","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1111\/j.1525-1594.2007.00350.x","article-title":"Hemodynamic controller for left ventricular assist device based on pulsatility ratio.","volume":"31","author":"Choi","year":"2007","journal-title":"Artif Organs"},{"key":"R52-20230821","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1111\/aor.12223","article-title":"A sliding mode-based starling-like controller for implantable rotary blood pumps.","volume":"38","author":"Bakouri","year":"2014","journal-title":"Artif Organs"},{"key":"R53-20230821","doi-asserted-by":"crossref","first-page":"E46","DOI":"10.1111\/aor.12221","article-title":"Starling-like flow control of a left ventricular assist device: In vitro validation.","volume":"38","author":"Gaddum","year":"2014","journal-title":"Artif Organs"},{"key":"R54-20230821","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/01.MAT.0000136652.78197.58","article-title":"Physiologic control of rotary blood pumps: An in vitro study.","volume":"50","author":"Giridharan","year":"2004","journal-title":"ASAIO J"},{"key":"R55-20230821","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1046\/j.1525-1594.2002.07136.x","article-title":"Nonlinear controller for ventricular assist devices.","volume":"26","author":"Giridharan","year":"2002","journal-title":"Artif Organs"},{"key":"R56-20230821","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1046\/j.1525-1594.2003.07089.x","article-title":"Control strategy for maintaining physiological perfusion with rotary blood pumps.","volume":"27","author":"Giridharan","year":"2003","journal-title":"Artif Organs"},{"key":"R57-20230821","doi-asserted-by":"crossref","first-page":"E24","DOI":"10.1111\/aor.12370","article-title":"Hemodynamic response to exercise and head-up tilt of patients implanted with a rotary blood pump: A computational modeling study.","volume":"39","author":"Lim","year":"2015","journal-title":"Artif Organs"},{"key":"R58-20230821","doi-asserted-by":"crossref","first-page":"24","DOI":"10.14797\/mdcj-11-1-24","article-title":"Gastrointestinal bleeding after continuous-flow left ventricular device implantation: Review of pathophysiology and management.","volume":"11","author":"Guha","year":"2015","journal-title":"Methodist Debakey Cardiovasc J"},{"issue":"3 Suppl","key":"R59-20230821","doi-asserted-by":"crossref","first-page":"S133","DOI":"10.1016\/S0003-4975(00)02634-5","article-title":"Clinical experience with the MicroMed DeBakey ventricular assist device.","volume":"71","author":"Noon","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"R60-20230821","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.healun.2008.10.007","article-title":"Intraoperative evaluation of the HeartMate II flow estimator.","volume":"28","author":"Slaughter","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"R61-20230821","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1097\/MAT.0b013e3181d2a56e","article-title":"Development of an inlet pressure sensor for control in a left ventricular assist device.","volume":"56","author":"Fritz","year":"2010","journal-title":"ASAIO J"},{"key":"R62-20230821","doi-asserted-by":"crossref","first-page":"1425","DOI":"10.1016\/j.jtcvs.2013.12.003","article-title":"Left atrial pressure monitoring in patients with a HeartMate II device using a Codman Microsensor.","volume":"147","author":"Gosev","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R63-20230821","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1109\/MRA.2003.1191711","article-title":"The development of control techniques for ventricular-assist devices and a hierarchical control structure to regulate the operation of a turbo-hydrodynamic assist device \u2013 hierarchical control of heart-assist devices.","volume":"10","author":"Boston","year":"2003","journal-title":"IEEE Robot Autom Mag"},{"key":"R64-20230821","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1161\/01.CIR.81.2.638","article-title":"Simultaneous conductance catheter and dimension assessment of left ventricle volume in the intact animal.","volume":"81","author":"Applegate","year":"1990","journal-title":"Circulation"},{"key":"R65-20230821","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1161\/01.CIR.70.5.812","article-title":"Continuous measurement of left ventricular volume in animals and humans by conductance catheter.","volume":"70","author":"Baan","year":"1984","journal-title":"Circulation"},{"key":"R66-20230821","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/01.MAT.0000150323.62708.35","article-title":"Comparison of pulsatile with nonpulsatile mechanical support in a porcine model of profound cardiogenic shock.","volume":"51","author":"Drakos","year":"2005","journal-title":"ASAIO J"},{"key":"R67-20230821","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1046\/j.1525-1594.1999.06408.x","article-title":"The effects of pulsatile versus nonpulsatile perfusion on blood viscoelasticity before and after deep hypothermic circulatory arrest in a neonatal piglet model.","volume":"23","author":"Undar","year":"1999","journal-title":"Artif Organs"},{"key":"R68-20230821","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1046\/j.1525-1594.2001.06859.x","article-title":"The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function.","volume":"25","author":"Endo","year":"2001","journal-title":"Artif Organs"},{"key":"R69-20230821","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1161\/CIRCHEARTFAILURE.110.958041","article-title":"Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device: Constant versus increasing pump speed: A pilot study.","volume":"4","author":"Brassard","year":"2011","journal-title":"Circ Heart Fail"},{"key":"R70-20230821","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1111\/aor.12070","article-title":"Exercise studies in patients with rotary blood pumps: Cause, effects, and implications for starling-like control of changes in pump flow.","volume":"37","author":"Salamonsen","year":"2013","journal-title":"Artif Organs"},{"key":"R71-20230821","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1161\/01.CIR.98.12.1178","article-title":"Comparison of exercise performance in patients with chronic severe heart failure versus left ventricular assist devices.","volume":"98","author":"Mancini","year":"1998","journal-title":"Circulation"},{"key":"R72-20230821","first-page":"128","article-title":"Are electronic cardiac devices still evolving?","volume":"9","author":"Carrault","year":"2014","journal-title":"Yearb Med Inform"},{"key":"R74-20230821","doi-asserted-by":"crossref","first-page":"2375","DOI":"10.1016\/j.jacc.2007.06.061","article-title":"Comparison of a radiofrequency-based wireless pressure sensor to swan-ganz catheter and echocardiography for ambulatory assessment of pulmonary artery pressure in heart failure.","volume":"50","author":"Verdejo","year":"2007","journal-title":"J Am Coll Cardiol"},{"key":"R75-20230821","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.cardfail.2010.08.002","article-title":"CHAMPION trial rationale and design: the long-term safety and clinical efficacy of a wireless pulmonary artery pressure monitoring system.","volume":"17","author":"Adamson","year":"2011","journal-title":"J Card Fail"},{"key":"R76-20230821","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/S0140-6736(11)60101-3","article-title":"Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: A randomised controlled trial.","volume":"377","author":"Abraham","year":"2011","journal-title":"Lancet"},{"key":"R77-20230821","doi-asserted-by":"crossref","first-page":"S218","DOI":"10.1016\/j.healun.2015.01.601","article-title":"Change of left atrial pressure, LAP measured with a wireless implantable pressure sensor (Titan sensor) during echocardiographic RAMP-test in HeartMate II patients.","volume":"34","author":"Hubbert","year":"2015","journal-title":"J Hear Lung Transplant"},{"key":"R78-20230821","doi-asserted-by":"crossref","first-page":"S13","DOI":"10.1016\/j.healun.2014.01.060","article-title":"First implantation in human of a wireless miniaturized intracardiac pressure sensor in a patient with a HeartMate IITM.","volume":"33","author":"Hubbert","year":"2014","journal-title":"J Hear Lung Transplant"},{"key":"R79-20230821","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1136\/hrt.2008.153486","article-title":"Chronic monitoring of pulmonary artery pressure in patients with severe heart failure: Multicentre experience of the monitoring Pulmonary Artery Pressure by Implantable device Responding to Ultrasonic Signal (PAPIRUS) II study.","volume":"95","author":"Hoppe","year":"2009","journal-title":"Heart"},{"key":"R80-20230821","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1054\/jcaf.2002.32373","article-title":"Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: A multicenter, 12-month follow-up study of patients with chronic heart failure.","volume":"8","author":"Magalski","year":"2002","journal-title":"J Card Fail"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00002480-201705000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T01:24:01Z","timestamp":1692667441000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00002480-201705000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5]]},"references-count":77,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000000477","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2017,5]]}}}