{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T02:03:14Z","timestamp":1793412194235,"version":"4.5.0"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,7]]},"abstract":"<jats:p>Treatment of end-stage heart failure includes cardiac transplantation or ventricular assist device (VAD) therapy. Although increasingly prevalent, current VAD therapy has inherent complications, including thrombosis. Studies have demonstrated that VAD implantation alters intracardiac blood flow, creating areas of stagnation that predispose to thrombus formation. Two potential surgical configurations exist for VAD implantation: through the apical or diaphragmatic surfaces of the heart. We hypothesized that diaphragmatic implantation causes more stagnation than apical implantation. We also hypothesized that intermittent aortic valve (AV) opening reduces stagnation of blood inside the left ventricle (LV) when compared with a closed AV. To test these hypotheses, a human LV geometry was recreated <jats:italic toggle=\"yes\">in silico<\/jats:italic> and a VAD inflow cannula was virtually implanted in each configuration. A computational indicator-dilution study was conducted where \u201cvirtually dyed blood\u201d was washed out of the LV by injecting blood with no dye. Simulations demonstrated a substantial reduction in stagnation with intermittent AV opening. In addition, virtual dye was cleared slightly faster in the apical configuration. Simulations from our study demonstrate the clinical importance of VAD management to allow intermittent opening of the AV to prevent subvalvular stagnation, and also suggests that apical configuration might be more hemodynamically favorable.<\/jats:p>","DOI":"10.1097\/mat.0000000000000503","type":"journal-article","created":{"date-parts":[[2016,12,25]],"date-time":"2016-12-25T12:39:54Z","timestamp":1482669594000},"page":"392-400","source":"Crossref","is-referenced-by-count":37,"title":["Impact of LVAD Implantation Site on Ventricular Blood Stagnation"],"prefix":"10.1097","volume":"63","author":[{"given":"Anthony R.","family":"Prisco","sequence":"first","affiliation":[{"name":"Department of Otolaryngology, Medical College of Wisconsin, Milwaukee, Wisconsin."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Aliseda","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, Medical College of Wisconsin, Milwaukee, Wisconsin."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer A.","family":"Beckman","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, Medical College of Wisconsin, Milwaukee, Wisconsin."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nahush A.","family":"Mokadam","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, Medical College of Wisconsin, Milwaukee, Wisconsin."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudius","family":"Mahr","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, Medical College of Wisconsin, Milwaukee, Wisconsin."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guilherme J. M.","family":"Garcia","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, Medical College of Wisconsin, Milwaukee, Wisconsin."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230821","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.pcad.2011.04.002","article-title":"Epidemiology and cost of advanced heart failure.","volume":"54","author":"Norton","year":"2011","journal-title":"Prog Cardiovasc Dis"},{"key":"R2-20230821","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Long-term use of a left ventricular assist device for end-stage heart failure.","volume":"345","author":"Rose","year":"2001","journal-title":"N Engl J Med"},{"key":"R3-20230821","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1161\/CIRCULATIONAHA.107.691972","article-title":"Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: Implications for patient selection.","volume":"116","author":"Lietz","year":"2007","journal-title":"Circulation"},{"key":"R4-20230821","first-page":"294","article-title":"The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling.","volume":"32","author":"Kar","year":"2005","journal-title":"Tex Heart Inst J"},{"key":"R5-20230821","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.healun.2010.11.014","article-title":"Diaphragmatic implantation of the HeartWare ventricular assist device.","volume":"30","author":"Gregoric","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"R6-20230821","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/j.healun.2010.05.016","article-title":"Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial.","volume":"29","author":"Wieselthaler","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R7-20230821","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.healun.2014.09.023","article-title":"In-hospital outcomes of a minimally invasive off-pump left thoracotomy approach using a centrifugal continuous-flow left ventricular assist device.","volume":"34","author":"Sileshi","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"R8-20230821","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1097\/MAT.0000000000000074","article-title":"Stroke while on long-term left ventricular assist device support: Incidence, outcome, and predictors.","volume":"60","author":"Morgan","year":"2014","journal-title":"ASAIO J"},{"key":"R9-20230821","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1159\/000083845","article-title":"Virchow\u2019s triad revisited: abnormal flow.","volume":"33","author":"Lowe","year":"2003","journal-title":"Pathophysiol Haemost Thromb"},{"key":"R10-20230821","doi-asserted-by":"crossref","first-page":"2400","DOI":"10.1016\/j.jbiomech.2010.04.020","article-title":"Device Thrombogenicity Emulator (DTE)\u2013design optimization methodology for cardiovascular devices: A study in two bileaflet MHV designs.","volume":"43","author":"Xenos","year":"2010","journal-title":"J Biomech"},{"key":"R11-20230821","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/01.mat.0000201961.97981.e9","article-title":"Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta.","volume":"52","author":"May-Newman","year":"2006","journal-title":"ASAIO J"},{"key":"R12-20230821","doi-asserted-by":"crossref","first-page":"3534","DOI":"10.1016\/j.cma.2009.04.015","article-title":"Patient-specific isogeometric fluid\u2013structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist device.","volume":"198","author":"Bazilevs","year":"2009","journal-title":"Comput Methods Appl Mecha Eng"},{"key":"R13-20230821","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1080\/10255842.2011.629616","article-title":"Computational fluid dynamics analysis of surgical adjustment of left ventricular assist device implantation to minimise stroke risk.","volume":"16","author":"Osorio","year":"2013","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R14-20230821","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1016\/j.jtcvs.2013.09.069","article-title":"Computational fluid dynamics in patients with continuous-flow left ventricular assist device support show hemodynamic alterations in the ascending aorta.","volume":"147","author":"Karmonik","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R15-20230821","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1097\/MAT.0000000000000034","article-title":"Thrombus formation patterns in the HeartMate II ventricular assist device: Clinical observations can be predicted by numerical simulations.","volume":"60","author":"Chiu","year":"2014","journal-title":"ASAIO J"},{"key":"R16-20230821","doi-asserted-by":"crossref","first-page":"021014","DOI":"10.1115\/1.4026254","article-title":"Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation-optimized HeartAssist 5 VAD.","volume":"136","author":"Chiu","year":"2014","journal-title":"J Biomech Eng"},{"key":"R17-20230821","doi-asserted-by":"crossref","first-page":"e32463","DOI":"10.1371\/journal.pone.0032463","article-title":"Device thrombogenicity emulation: A novel method for optimizing mechanical circulatory support device thromboresistance.","volume":"7","author":"Girdhar","year":"2012","journal-title":"PLoS One"},{"key":"R18-20230821","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1097\/MAT.0b013e318299fced","article-title":"Thromboembolism is linked to intraventricular flow stasis in a patient supported with a left ventricle assist device.","volume":"59","author":"May-Newman","year":"2013","journal-title":"ASAIO J"},{"key":"R19-20230821","doi-asserted-by":"crossref","first-page":"3058","DOI":"10.1007\/s10439-010-0065-8","article-title":"Flow residence time and regions of intraluminal thrombus deposition in intracranial aneurysms.","volume":"38","author":"Rayz","year":"2010","journal-title":"Ann Biomed Eng"},{"key":"R20-20230821","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1161\/CIRCHEARTFAILURE.109.917765","article-title":"The development of aortic insufficiency in left ventricular assist device-supported patients.","volume":"3","author":"Cowger","year":"2010","journal-title":"Circ Heart Fail"},{"key":"R21-20230821","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1016\/j.healun.2008.05.029","article-title":"Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device.","volume":"27","author":"Mudd","year":"2008","journal-title":"J Heart Lung Transplant"},{"key":"R22-20230821","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1016\/j.healun.2010.05.018","article-title":"Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices.","volume":"29","author":"Pak","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R23-20230821","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1016\/j.athoracsur.2014.05.030","article-title":"De novo aortic regurgitation after continuous-flow left ventricular assist device implantation.","volume":"98","author":"Patil","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"R24-20230821","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.athoracsur.2012.09.020","article-title":"The development of aortic insufficiency in continuous-flow left ventricular assist device-supported patients.","volume":"95","author":"Aggarwal","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"R25-20230821","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1093\/icvts\/ivt263","article-title":"Analysis of aortic valve commissural fusion after support with continuous-flow left ventricular assist device.","volume":"17","author":"Martina","year":"2013","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"R26-20230821","doi-asserted-by":"crossref","first-page":"2152","DOI":"10.1016\/j.jbiomech.2015.11.049","article-title":"A clinical method for mapping and quantifying blood stasis in the left ventricle.","volume":"49","author":"Rossini","year":"2016","journal-title":"J Biomech"},{"key":"R27-20230821","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.1016\/j.jacc.2014.06.1205","article-title":"Contribution of the diastolic vortex ring to left ventricular filling.","volume":"64","author":"Mart\u00ednez-Legazpi","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"R28-20230821","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1001\/archinte.1916.00080130010002","article-title":"Clinical calorimetry: tenth paper a formula to estimate the approximate surface area if height and weight be known.","volume":"17","author":"Du Bois","year":"1916","journal-title":"Arch Intern Med"},{"issue":"8 suppl","key":"R29-20230821","doi-asserted-by":"crossref","first-page":"S89","DOI":"10.1016\/S1053-2498(99)00110-2","article-title":"Left ventricular assist device implantation: Short and long-term surgical complications.","volume":"19","author":"Piccione","year":"2000","journal-title":"J Heart Lung Transplant"},{"key":"R30-20230821","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1084\/jem.46.1.13","article-title":"Studies in experimental extracorporeal thrombosis: II. Thrombus formation in normal blood in the extracorporeal vascular loop.","volume":"46","author":"Shionoya","year":"1927","journal-title":"J Exp Med"},{"issue":"S180","key":"R31-20230821","article-title":"Device thrombogenicity emulation: A novel methodology to predict \u201cHot Spot\u201d sites of thrombus formation in continuous flow VADs.","volume":"32","author":"Slepian","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R32-20230821","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1136\/heart.89.9.983","article-title":"Pathology of coronary microembolisation and no reflow.","volume":"89","author":"Falk","year":"2003","journal-title":"Heart"},{"key":"R33-20230821","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1136\/hrt.82.5.547","article-title":"Left atrial appendage: Structure, function, and role in thromboembolism.","volume":"82","author":"Al-Saady","year":"1999","journal-title":"Heart"},{"key":"R34-20230821","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1097\/MAT.0000000000000443","article-title":"LVAD outflow graft angle and thrombosis risk.","volume":"63","author":"Aliseda","year":"2017","journal-title":"ASAIO J"},{"key":"R35-20230821","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1016\/j.compbiomed.2012.06.010","article-title":"Fluid-dynamics modelling of the human left ventricle with dynamic mesh for normal and myocardial infarction: preliminary study.","volume":"42","author":"Khalafvand","year":"2012","journal-title":"Comput Biol Med"},{"key":"R36-20230821","doi-asserted-by":"crossref","first-page":"3346","DOI":"10.1007\/s10439-016-1614-6","article-title":"Image-based simulations show important flow fluctuations in a normal left ventricle: what could be the implications?","volume":"44","author":"Chnafa","year":"2016","journal-title":"Ann Biomed Eng"},{"key":"R37-20230821","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1017\/S0022112005005550","article-title":"Three-dimensional filling flow into a model left ventricle.","volume":"539","author":"Domenichini","year":"2005","journal-title":"J Fluid Mech"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00002480-201707000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T01:43:20Z","timestamp":1692668600000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00002480-201707000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7]]},"references-count":37,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000000503","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2017,7]]}}}