{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:19:50Z","timestamp":1786119590146,"version":"build-2736575974"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,11]]},"abstract":"<jats:p>\n                    No study has systematically evaluated the prevalence and dosages of diuretic use for patients after left ventricular assist device (LVAD) implantation. The primary objective was to characterize chronologic change in prevalence and doses of loop diuretics after LVAD placement. The secondary objective was to identify correlates of actual doses of loop diuretics. We retrospectively reviewed medical records of adult patients with LVAD implantation at the University of Kentucky. Prevalence of diuretic use and furosemide equivalent dose were assessed before LVAD implantation and at seven time points thereafter: 1 week, 1 month, 3 months, 6 months, 1 year, 18 months, and 2 years. Correlation analyses and linear mixed modeling were used to identify correlates of diuretic dose before and after LVAD implantation. Eighty-two consecutive eligible patients were reviewed. The prevalence of loop diuretic use was 95% at baseline but significantly lower than that at all subsequent time points (\n                    <jats:italic toggle=\"yes\">p<\/jats:italic>\n                    &lt; 0.048 for all). Nevertheless, more than half of patients on whom we had such follow-up data were on loop diuretics 2 years after LVAD implantation. Average furosemide equivalent dose was significantly lower at every time point after implantation compared with baseline (\n                    <jats:italic toggle=\"yes\">p<\/jats:italic>\n                    &lt; 0.006 for all). Blood urine nitrogen (BUN) was the most robust predictor of dose after LVAD implant. The prevalence and average furosemide equivalent dose were significantly reduced after LVAD implantation, but the use of loop diuretic remained more than 50% for up to 2 years. Consistent association with BUN may indirectly indicate overuse of diuretics post-LVAD implant.\n                  <\/jats:p>","DOI":"10.1097\/mat.0000000000000565","type":"journal-article","created":{"date-parts":[[2017,3,23]],"date-time":"2017-03-23T02:14:57Z","timestamp":1490235297000},"page":"774-780","source":"Crossref","is-referenced-by-count":6,"title":["Chronologic Changes and Correlates of Loop Diuretic Dose in Patients with Left Ventricular Assist Device"],"prefix":"10.1097","volume":"63","author":[{"given":"Kazuhiko","family":"Kido","sequence":"first","affiliation":[{"name":"Department of Pharmacy, University of Kentucky HealthCare, Lexington, Lexington, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bennet","family":"George","sequence":"additional","affiliation":[{"name":"Department of Pharmacy, University of Kentucky HealthCare, Lexington, Lexington, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard J.","family":"Charnigo","sequence":"additional","affiliation":[{"name":"Department of Pharmacy, University of Kentucky HealthCare, Lexington, Lexington, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tracy E.","family":"Macaulay","sequence":"additional","affiliation":[{"name":"Department of Pharmacy, University of Kentucky HealthCare, Lexington, Lexington, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara D.","family":"Brouse","sequence":"additional","affiliation":[{"name":"Department of Pharmacy, University of Kentucky HealthCare, Lexington, Lexington, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maya","family":"Guglin","sequence":"additional","affiliation":[{"name":"Department of Pharmacy, University of Kentucky HealthCare, Lexington, Lexington, Kentucky."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230821","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.healun.2012.09.013","article-title":"The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: Executive summary.","volume":"32","author":"Feldman","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R2-20230821","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1161\/CIRCULATIONAHA.113.002836","article-title":"Assessment and management of heart failure after left ventricular assist device implantation.","volume":"129","author":"Burke","year":"2014","journal-title":"Circulation"},{"key":"R3-20230821","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.cardfail.2009.11.002","article-title":"Right ventricular dysfunction during intensive pharmacologic unloading persists after mechanical unloading.","volume":"16","author":"Palardy","year":"2010","journal-title":"J Card Fail"},{"key":"R4-20230821","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1016\/j.healun.2015.06.015","article-title":"Right ventricular failure after left ventricular assist devices.","volume":"34","author":"Lampert","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"R5-20230821","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1016\/j.healun.2010.05.018","article-title":"Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices.","volume":"29","author":"Pak","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R6-20230821","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s10741-012-9354-7","article-title":"Efficacy and safety of loop diuretic therapy in acute decompensated heart failure: A clinical review.","volume":"19","author":"Leto","year":"2014","journal-title":"Heart Fail Rev"},{"key":"R7-20230821","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1517\/17425255.2011.586629","article-title":"Metabolic and toxicological considerations for diuretic therapy in patients with acute heart failure.","volume":"7","author":"Aspromonte","year":"2011","journal-title":"Expert Opin Drug Metab Toxicol"},{"key":"R8-20230821","first-page":"861","article-title":"Humoral and hemodynamic responses after left ventricular assist device implantation and heart transplantation.","volume":"231","author":"Wagner","year":"2006","journal-title":"Exp Biol Med (Maywood)"},{"issue":"4 Suppl","key":"R9-20230821","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.healun.2010.01.011","article-title":"Clinical management of continuous-flow left ventricular assist devices in advanced heart failure.","volume":"29","author":"Slaughter","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R10-20230821","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/j.ccc.2014.04.001","article-title":"Left ventricular assist device management and complications.","volume":"30","author":"Birati","journal-title":"Crit Care Clin"},{"key":"R11-20230821","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s11897-010-0043-3","article-title":"Management of right ventricular failure in the era of ventricular assist device therapy.","volume":"8","author":"Craig","year":"2011","journal-title":"Curr Heart Fail Rep"},{"key":"R12-20230821","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1016\/j.hfc.2014.07.008","article-title":"The role of heart failure pharmacotherapy after left ventricular assist device support.","volume":"10","author":"Rommel","year":"2014","journal-title":"Heart Fail Clin"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00002480-201711000-00014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T18:55:38Z","timestamp":1786042538000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00002480-201711000-00014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11]]},"references-count":12,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000000565","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2017,11]]}}}