{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T12:31:27Z","timestamp":1763037087288},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:p>Right ventricular failure (RVF) is a significant issue when considering left ventricular assist device (LVAD) implantation in pediatrics. The aim of this study was to evaluate the effects of LVAD on right ventricular (RV) function in children. We retrospectively reviewed clinical and echocardiographic data of children who underwent Berlin Heart EXCOR LVAD focusing on RV function before and after implantation (1, 3, and 6 month follow-up). An isolated LVAD was used in 27 patients. Median age was 11 months (interquartile range [IQR]: 5\u201324 months), with a median weight of 6.3\u2009kg (IQR: 5\u20139\u2009kg). Median time on ventricular assist device (VAD) support was 147 days (IQR: 86\u2013210 days). Twenty patients were successfully bridged to orthotopic heart transplantation (OHT) (74%), six patients died (22%), and also heart function recovered in one patient (4%). Before LVAD implantation, nine patients (33%) showed a RV fractional area change (RVFAC) less than or equal to 30%. After implantation, mean RVFAC increased up until the 3 month follow-up (43.13%; <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.033) and then slightly decreased. In a subgroup of 18 patients, the average strain value increased after the 1 month follow-up (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.022). Right ventricular failure developed in 33% of patients before the 1 month follow-up, and 7.4% experienced RVF at the 6 month follow-up. No patient required biventricular assist device (BiVAD). In our population, pulsatile-flow LVAD in children allows optimal RV decompression and function post-LVAD as measured by improvement in RV function at echo particularly at 1 and 3 month follow-up. At long-term follow-up, the beneficial effects of LVAD on RV function seem to be reduced as signs and symptoms of late RVF may develop in some patients despite LVAD support.<\/jats:p>","DOI":"10.1097\/mat.0000000000000596","type":"journal-article","created":{"date-parts":[[2017,5,16]],"date-time":"2017-05-16T17:00:34Z","timestamp":1494954034000},"page":"91-97","source":"Crossref","is-referenced-by-count":9,"title":["Acute and Long-Term Effects of LVAD Support on Right Ventricular Function in Children with Pediatric Pulsatile Ventricular Assist Devices"],"prefix":"10.1097","volume":"64","author":[{"given":"Roberta","family":"Iacobelli","sequence":"first","affiliation":[{"name":"Department of Cardiology and Cardiac Surgery, Bambino Ges\u00f9 Pediatric Hospital, Rome, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arianna","family":"Di Molfetta","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiac Surgery, Bambino Ges\u00f9 Pediatric Hospital, Rome, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianluca","family":"Brancaccio","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiac Surgery, Bambino Ges\u00f9 Pediatric Hospital, Rome, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergio","family":"Filippelli","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiac Surgery, Bambino Ges\u00f9 Pediatric Hospital, Rome, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefano","family":"Morelli","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiac Surgery, Bambino Ges\u00f9 Pediatric Hospital, Rome, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benedetta","family":"Natali","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiac Surgery, Bambino Ges\u00f9 Pediatric Hospital, Rome, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessandra","family":"Toscano","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiac Surgery, Bambino Ges\u00f9 Pediatric Hospital, Rome, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabrizio","family":"Drago","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiac Surgery, Bambino Ges\u00f9 Pediatric Hospital, Rome, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Amodeo","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiac Surgery, Bambino Ges\u00f9 Pediatric Hospital, Rome, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230821","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1016\/j.jtcvs.2013.11.012","article-title":"Right ventricular dysfunction in children supported with pulsatile ventricular assist devices.","volume":"147","author":"Karimova","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R2-20230821","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1111\/ctr.12577","article-title":"Right ventricular failure after implantation of continuous flow left ventricular assist device: Analysis of predictors and outcomes.","volume":"29","author":"Lo","year":"2015","journal-title":"Clin Transplant"},{"key":"R3-20230821","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1016\/j.healun.2008.07.022","article-title":"Tricuspid annular motion as a predictor of severe right ventricular failure after left ventricular assist device implantation.","volume":"27","author":"Puwanant","year":"2008","journal-title":"J Heart Lung Transplant"},{"issue":"5 pt 2","key":"R4-20230821","first-page":"II353","article-title":"Does septal position affect right ventricular function during left ventricular assist in an experimental porcine model?","volume":"90","author":"Hendry","year":"1994","journal-title":"Circulation"},{"issue":"5 suppl","key":"R5-20230821","first-page":"II316","article-title":"Right ventricular\/arterial coupling in the patient with left ventricular assistance.","volume":"86","author":"Morita","year":"1992","journal-title":"Circulation"},{"key":"R6-20230821","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1253\/circj.CJ-15-0093","article-title":"Assessment and management of right ventricular failure in left ventricular assist device patients.","volume":"79","author":"Holman","year":"2015","journal-title":"Circ J"},{"key":"R7-20230821","first-page":"585","article-title":"Biventricular VAD versus LVAD for right heart failure.","volume":"3","author":"Boulate","year":"2014","journal-title":"Ann Cardiothorac Surg"},{"key":"R8-20230821","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.cardfail.2012.11.001","article-title":"Postoperative right ventricular failure after left ventricular assist device placement is predicted by preoperative echocardiographic structural, hemodynamic, and functional parameters.","volume":"19","author":"Raina","year":"2013","journal-title":"J Card Fail"},{"key":"R9-20230821","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1161\/CIRCULATIONAHA.106.674028","article-title":"Comprehensive invasive and noninvasive approach to the right ventricle\u2013pulmonary circulation unit. State of the art and clinical and research implications.","volume":"120","author":"Champion","year":"2009","journal-title":"Circulation"},{"key":"R10-20230821","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1016\/j.healun.2008.07.021","article-title":"INTERMACS database for durable devices for circulatory support: First annual report.","volume":"27","author":"Kirklin","year":"2008","journal-title":"J Heart Lung Transplant"},{"key":"R11-20230821","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1016\/j.echo.2009.01.008","article-title":"Tissue Doppler imaging measurement of LV systolic function in children: Mitral annular displacement index is superior to peak velocity.","volume":"22","author":"Roberson","year":"2009","journal-title":"J Am Soc Echocardiogr"},{"key":"R12-20230821","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1111\/j.1540-8175.2011.01519.x","article-title":"Assessment of Right Ventricular Function Using Echocardiographic Speckle Tracking of the Tricuspid Annular Motion: Comparison with Cardiac Magnetic Resonance.","volume":"29","author":"Ahmad","year":"2012","journal-title":"Echocardiography"},{"key":"R13-20230821","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1161\/01.CIR.66.4.777","article-title":"Evaluation of tricuspid regurgitation by pulsed Doppler and two-dimensional echocardiography.","volume":"66","author":"Miyatake","year":"1982","journal-title":"Circulation"},{"key":"R14-20230821","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/j.recesp.2011.04.006","article-title":"Determination of normalized values of the tricuspid annular plane systolic excursion (TAPSE) in 405 Spanish children and adolescents.","volume":"64","author":"N\u00fa\u00f1ez-Gil","year":"2011","journal-title":"Rev Esp Cardiol"},{"key":"R15-20230821","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/j.echo.2009.03.026","article-title":"Right ventricular function in infants, children and adolescents: Reference values of the tricuspid annular plane systolic excursion (TAPSE) in 640 healthy patients and calculation of z score values.","volume":"22","author":"Koestenberger","year":"2009","journal-title":"J Am Soc Echocardiogr"},{"key":"R16-20230821","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.echo.2014.01.015","article-title":"Normal ranges of right ventricular systolic and diastolic strain measures in children: A systematic review and meta-analysis.","volume":"27","author":"Levy","year":"2014","journal-title":"J Am Soc Echocardiogr"},{"key":"R17-20230821","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.healun.2016.03.005","article-title":"Adverse events in children implanted with ventricular assist devices in the United States: Data from the Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS).","volume":"35","author":"Rosenthal","year":"2016","journal-title":"J Heart Lung Transplant"},{"key":"R18-20230821","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1097\/00002216-198907000-00086","article-title":"Computer model of ventricular interaction during left ventricular circulatory support.","volume":"35","author":"Woodard","year":"1989","journal-title":"ASAIO Trans"},{"key":"R19-20230821","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/S0022-5223(19)34720-8","article-title":"Right heart function during prosthetic left ventricular assistance in a porcine model of congestive heart failure.","volume":"104","author":"Chow","year":"1992","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R20-20230821","doi-asserted-by":"crossref","first-page":"944","DOI":"10.1161\/01.RES.70.5.944","article-title":"Isolated ventricular systolic interaction during transient reductions in left ventricular pressure.","volume":"70","author":"Woodard","year":"1992","journal-title":"Circ Res"},{"key":"R21-20230821","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1164\/rccm.200604-547OC","article-title":"Tricuspid annular displacement predicts survival in pulmonary hypertension.","volume":"174","author":"Forfia","year":"2006","journal-title":"Am J Respir Crit Care Med"},{"key":"R22-20230821","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1016\/S0002-9149(99)00877-2","article-title":"Prognostic usefulness of the tricuspid annular plane systolic excursion in patients with congestive heart failure secondary to idiopathic or ischemic dilated cardiomyopathy.","volume":"85","author":"Ghio","year":"2000","journal-title":"Am J Cardiol"},{"key":"R23-20230821","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/j.jacc.2012.02.073","article-title":"Independent and incremental role of quantitative right ventricular evaluation for the prediction of right ventricular failure after left ventricular assist device implantation.","volume":"60","author":"Grant","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"R24-20230821","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.cardfail.2014.04.017","article-title":"Right ventricular systolic and diastolic function as assessed by speckle-tracking echocardiography improve with prolonged isolated left ventricular assist device support.","volume":"20","author":"Herod","year":"2014","journal-title":"J Card Fail"},{"key":"R25-20230821","doi-asserted-by":"crossref","first-page":"113","DOI":"10.4250\/jcu.2014.22.3.113","article-title":"Validation of global longitudinal strain and strain rate as reliable markers of right ventricular dysfunction: Comparison with cardiac magnetic resonance and outcome.","volume":"22","author":"Park","year":"2014","journal-title":"J Cardiovasc Ultrasound"},{"key":"R26-20230821","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/j.healun.2012.12.018","article-title":"Impact of continuous-flow left ventricular assist device support on right ventricular function.","volume":"32","author":"Morgan","year":"2013","journal-title":"J Heart Lung Transplant"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00002480-201801000-00014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T00:55:53Z","timestamp":1692665753000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00002480-201801000-00014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000000596","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2018,1]]}}}