{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T15:52:28Z","timestamp":1756309948178},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,3]]},"abstract":"<jats:p>Optimal function of left ventricular assist devices (LVADs) depends on proper alignment of the inflow cannula (IC). Quantitative guidelines for IC angulation are lacking because of variation in cardiac geometry and difficulty in analyzing three-dimensional (3D) cannula orientation relative to the left ventricle (LV). Based on contrast-enhanced computed tomography images from five normal and five clinically malpositioned IC cases in patients with HeartMate II LVADs, we developed a method for 3D quantification of IC malpositioning. Using Mimics image software (Materialise, Leuven, Belgium), the native heart, major arteries, and LVAD were segmented to create patient-specific 3D models, allowing LV cavity volume and long-axis length to be measured directly. The deviation of the IC was quantified in a cylindrical coordinate system at the IC insertion point relative to the mitral valve and septum, and IC occlusion was assessed by the distance between cannula inlet and the proximal endocardium. Compared with normal cases, patients with malpositioned pumps had shorter LV length (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.03) and reduced pump pocket depth (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.009). Malpositioned pumps may experience greater obstruction by the nearby myocardium. This quantitative 3D modeling tool may help identify different modes of pump malalignment and migration and may facilitate preoperative planning and minimally invasive approaches via virtual LVAD implantation.<\/jats:p>","DOI":"10.1097\/mat.0000000000000628","type":"journal-article","created":{"date-parts":[[2017,7,26]],"date-time":"2017-07-26T20:25:57Z","timestamp":1501100757000},"page":"154-158","source":"Crossref","is-referenced-by-count":6,"title":["Novel Cardiac Coordinate Modeling System for Three-Dimensional Quantification of Inflow Cannula Malposition of HeartMate II LVADs"],"prefix":"10.1097","volume":"64","author":[{"given":"Brian","family":"Lima","sequence":"first","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Onur","family":"Dur","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joyce","family":"Chuang","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Themistokles","family":"Chamogeorgakis","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David J.","family":"Farrar","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kartik S.","family":"Sundareswaran","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joost","family":"Felius","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susan M.","family":"Joseph","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shelley A.","family":"Hall","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gonzalo V.","family":"Gonzalez-Stawinski","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Baylor University Medical Center, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230821","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1016\/j.healun.2015.10.003","article-title":"Seventh INTERMACS annual report: 15,000 patients and counting.","volume":"34","author":"Kirklin","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"R2-20230821","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.healun.2013.05.002","article-title":"Algorithm for the diagnosis and management of suspected pump thrombus.","volume":"32","author":"Goldstein","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R3-20230821","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1016\/j.athoracsur.2013.05.081","article-title":"Surgical technique influences HeartMate II left ventricular assist device thrombosis.","volume":"96","author":"Taghavi","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"R4-20230821","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.healun.2013.10.005","article-title":"Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: A multifactorial phenomenon.","volume":"33","author":"Uriel","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"R5-20230821","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1111\/jocs.12478","article-title":"Principles of HeartMate II implantation to avoid pump malposition and migration.","volume":"30","author":"Adamson","year":"2015","journal-title":"J Card Surg"},{"key":"R6-20230821","article-title":"HeartMate II left ventricular assist device pump exchange: A single-institution experience.","author":"Shaikh","year":"2016","journal-title":"Thorac Cardiovasc Surg"},{"key":"R7-20230821","doi-asserted-by":"crossref","first-page":"1617","DOI":"10.1016\/j.healun.2015.07.006","article-title":"Radiologic assessment of HeartMate II position: Minimal pump migration after long-term support.","volume":"34","author":"Adamson","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"R8-20230821","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.jcct.2011.01.009","article-title":"Left ventricular assist device malposition interrogated by 4-D cine computed tomography.","volume":"5","author":"Bolen","year":"2011","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R9-20230821","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1097\/MAT.0b013e3182a4b30f","article-title":"Postimplant left ventricular assist device fit analysis using three-dimensional reconstruction.","volume":"59","author":"Truong","year":"2013","journal-title":"ASAIO J"},{"key":"R10-20230821","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.1097\/BRS.0b013e3181d323ab","article-title":"Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: Retrospective study.","volume":"35","author":"Devito","year":"2010","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00002480-201803000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T02:00:37Z","timestamp":1692669637000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00002480-201803000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":10,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000000628","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2018,3]]}}}