{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T20:08:12Z","timestamp":1769112492453,"version":"3.49.0"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8]]},"abstract":"<jats:p>Aortic valve insufficiency can be addressed during continuous-flow left ventricular assist device (CF-LVAD) implantation by performing aortic valve repair or replacement, or patch closure of the left ventricular outflow tract (LVOT). However, few studies have examined the safety of long-term CF-LVAD support after LVOT closure. From November 2003 through March 2016, 16 patients with advanced chronic heart failure underwent CF-LVAD implantation and concomitant LVOT closure for severe aortic insufficiency. We compared their long-term outcomes with those of 510 CF-LVAD recipients without concomitant LVOT closure. Total support time was 26.1 patient-years in the LVOT-closure group and 938.6 patient-years in the CF-LVAD\u2013only group. Survival at 30 days, 6 months, 1 year, and 2 years was similar for CF-LVAD\u2013only patients (90.4%, 80.6%, 74.3%, 67.5%) and LVOT-closure patients (81.3%, 81.3%, 75.0%, 68.8%; <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.59). There were no deaths related to LVOT closure. The event rate per patient-year for neurologic dysfunction (ND) was 0.23 in the LVOT-closure group (6 ND events) and 0.20 in the CF-LVAD\u2013only group (136 ND events; <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.97). We conclude that for select patients with aortic insufficiency who are undergoing CF-LVAD implantation, LVOT closure produces acceptable outcomes and, therefore, is a viable option.<\/jats:p>","DOI":"10.1097\/mat.0000000000000856","type":"journal-article","created":{"date-parts":[[2018,8,3]],"date-time":"2018-08-03T23:30:10Z","timestamp":1533339010000},"page":"558-564","source":"Crossref","is-referenced-by-count":3,"title":["Long-Term Continuous-Flow Left Ventricular Assist Device Support After Left Ventricular Outflow Tract Closure"],"prefix":"10.1097","volume":"65","author":[{"given":"Chitaru","family":"Kurihara","sequence":"first","affiliation":[{"name":"Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, Texas"},{"name":"Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, Texas"},{"name":"Department of Cardiothoracic Surgery, Tokyo Metropolitan Geriatric Hospital and Institute of Gerontology, Tokyo, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William E.","family":"Cohn","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, Texas"},{"name":"Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Kawabori","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, Texas"},{"name":"Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tadahisa","family":"Sugiura","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, Texas"},{"name":"Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew B.","family":"Civitello","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, Texas"},{"name":"Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeffrey A.","family":"Morgan","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Transplant and Assist Devices, Baylor College of Medicine, Houston, Texas"},{"name":"Department of Cardiopulmonary Transplantation and the Center for Cardiac Support, Texas Heart Institute, Houston, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230821","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1016\/j.athoracsur.2008.06.030","article-title":"Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.","volume":"86","author":"John","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"R2-20230821","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.healun.2010.01.011","article-title":"Clinical management of continuous-flow left ventricular assist devices in advanced heart failure.","volume":"29","author":"Slaughter","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R3-20230821","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","article-title":"Advanced heart failure treated with continuous-flow left ventricular assist device.","volume":"361","author":"Slaughter","year":"2009","journal-title":"N Engl J Med"},{"key":"R4-20230821","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1097\/MAT.0b013e318271bc49","article-title":"Modified central closure technique for treatment of aortic insufficiency in patients on left ventricular assist device support.","volume":"58","author":"Morgan","year":"2012","journal-title":"ASAIO J"},{"key":"R5-20230821","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/S0022-5223(03)01301-1","article-title":"Management of aortic insufficiency in patients with left ventricular assist devices: A simple coaptation stitch method (Park\u2019s stitch).","volume":"127","author":"Park","year":"2004","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R6-20230821","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.healun.2010.08.025","article-title":"Surgical closure of left ventricular outflow tract after left ventricular assist device implantation in patients with aortic valve pathology.","volume":"30","author":"Cohn","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"R7-20230821","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.jtcvs.2010.11.003","article-title":"The sandwich plug technique: Simple, effective, and rapid closure of a mechanical aortic valve prosthesis at left ventricular assist device implantation.","volume":"142","author":"Cohn","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R8-20230821","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/S1053-2498(01)00354-0","article-title":"Alternative approach for use of a left ventricular assist device with a thrombosed prosthetic valve.","volume":"21","author":"Pelletier","year":"2002","journal-title":"J Heart Lung Transplant"},{"key":"R9-20230821","doi-asserted-by":"crossref","first-page":"1448","DOI":"10.1016\/S0003-4975(01)02479-1","article-title":"Surgical management of valvular disease in patients requiring left ventricular assist device support.","volume":"71","author":"Rao","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"R10-20230821","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1067\/mtc.2001.114770","article-title":"Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: Signs, symptoms, and concerns.","volume":"122","author":"Samuels","year":"2001","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R11-20230821","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1016\/j.athoracsur.2005.08.072","article-title":"Native aortic valve insufficiency in patients with left ventricular assist devices.","volume":"81","author":"Bryant","year":"2006","journal-title":"Ann Thorac Surg"},{"key":"R12-20230821","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1016\/S1053-2498(02)01180-4","article-title":"Total left ventricular outflow tract obstruction due to left ventricular assist device-induced sub-aortic thrombosis in 2 patients with aortic valve bioprosthesis.","volume":"22","author":"Rose","year":"2003","journal-title":"J Heart Lung Transplant"},{"key":"R13-20230821","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.healun.2016.08.006","article-title":"Impact of aortic valve closure on adverse events and outcomes with the HeartWare ventricular assist device.","volume":"36","author":"Dobarro","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"R14-20230821","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1016\/j.healun.2014.11.008","article-title":"Concomitant aortic valve procedures in patients undergoing implantation of continuous-flow left ventricular assist devices: An INTERMACS database analysis.","volume":"34","author":"Robertson","year":"2015","journal-title":"J Heart Lung Transplant"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00002480-201908000-00007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T02:11:24Z","timestamp":1692670284000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00002480-201908000-00007"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8]]},"references-count":14,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000000856","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2019,8]]}}}