{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T16:42:34Z","timestamp":1780764154783,"version":"3.54.1"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:p>We examined cardiac features associated with residual mitral regurgitation (MR) following continuous-flow left ventricular assist device (cfLVAD) implant. From 2003 to 2017, 134 patients with severe MR underwent cfVLAD implant without mitral valve (MV) intervention. Echocardiographic (echo) assessment occurred pre-cfLVAD, early post-cfLVAD, and at last available echo. Ventricular and atrial volumes were calculated from established formulas and normalized to be predicted. Cluster analysis based on preoperative normalized left ventricular and atrial volumes, and MV height identified grades 1, 2, and 3 with progressively larger cardiac chamber sizes. Median early echo follow-up was 0.92 (0.55, 1.45) months and the last follow-up was 15.12 (5.28, 38.28) months. Mitral regurgitation improved early after cfLVAD by 2.10 \u00b1 1.16 grades (<jats:italic toggle=\"yes\">\n                              p\n                           <\/jats:italic> &lt; 0.01). Mitral regurgitation severity at the last echocardiogram positively correlated with the preoperative left ventricular volume (<jats:italic toggle=\"yes\">\n                              p\n                           <\/jats:italic> = 0.014, R = 0.212), left atrial volume (<jats:italic toggle=\"yes\">\n                              p\n                           <\/jats:italic> = 0.007, R = 0.233), MV anteroposterior height (<jats:italic toggle=\"yes\">\n                              p\n                           <\/jats:italic> = 0.032, R = 0.185), and MV mediolateral diameter (<jats:italic toggle=\"yes\">\n                              p\n                           <\/jats:italic> = 0.043, R = 0.175). Morphologically, smaller grade 1 hearts were correlated with MR resolution at the late follow-up (<jats:italic toggle=\"yes\">\n                              p\n                           <\/jats:italic> = 0.023). Late right ventricular failure (RVF) at the last clinical follow-up was less in grade 1 (4\/48 [8.3%]) compared with grades 2 and 3 (26\/86 [30.2%]), <jats:italic toggle=\"yes\">\n                              p\n                           <\/jats:italic> = 0.004). Grade 1 cardiac dimensions correlates with improvement in severe MR and had less late RVF.<\/jats:p>","DOI":"10.1097\/mat.0000000000001379","type":"journal-article","created":{"date-parts":[[2021,2,25]],"date-time":"2021-02-25T13:45:19Z","timestamp":1614260719000},"page":"1139-1147","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Left Ventricular Assist Device Implantation in Patients with Preoperative Severe Mitral Regurgitation"],"prefix":"10.1097","volume":"67","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4211-8587","authenticated-orcid":false,"given":"Paul C.","family":"Tang","sequence":"first","affiliation":[{"name":"Department of Cardiac Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neal M.","family":"Duggal","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan W.","family":"Haft","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew A.","family":"Romano","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven F.","family":"Bolling","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashraf","family":"Abou El Ela","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoting","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monica M.","family":"Colvin","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Cardiovascular Medicine, University of Michigan Frankel Cardiovascular Center, Ann Arbor, Michigan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keith D.","family":"Aaronson","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Cardiovascular Medicine, University of Michigan Frankel Cardiovascular Center, Ann Arbor, Michigan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4430-9969","authenticated-orcid":false,"given":"Francis D.","family":"Pagani","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,2,4]]},"reference":[{"key":"R1-20250530","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1097\/MAT.0b013e31826e4267","article-title":"Left ventricular reverse remodeling with a continuous flow left ventricular assist device measured by left ventricular end-diastolic dimensions and severity of mitral regurgitation.","volume":"58","author":"Morgan","year":"2012","journal-title":"ASAIO J"},{"key":"R2-20250530","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1097\/MAT.0b013e31829ff57d","article-title":"Mitral regurgitation and axial flow left ventricular assist device: A computer simulation study.","volume":"59","author":"Jelenc","year":"2013","journal-title":"ASAIO J"},{"key":"R3-20250530","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1016\/j.healun.2014.11.023","article-title":"Uncorrected pre-operative mitral valve regurgitation is not associated with adverse outcomes after continuous-flow left ventricular assist device implantation.","volume":"34","author":"Stulak","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"R4-20250530","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1007\/s10047-018-1076-8","article-title":"Effect of concomitant mitral valve procedures for severe mitral regurgitation during left ventricular assist device implantation.","volume":"22","author":"Kawabori","year":"2019","journal-title":"J Artif Organs"},{"key":"R5-20250530","doi-asserted-by":"crossref","first-page":"897.e4","DOI":"10.1016\/j.jtcvs.2019.03.089","article-title":"Right ventricular function and residual mitral regurgitation after left ventricular assist device implantation determines the incidence of right heart failure.","volume":"159","author":"Tang","year":"2020","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R6-20250530","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.healun.2017.09.016","article-title":"Concomitant mitral valve procedures in patients undergoing implantation of continuous-flow left ventricular assist devices: An INTERMACS database analysis.","volume":"37","author":"Robertson","year":"2018","journal-title":"J Heart Lung Transplant"},{"key":"R7-20250530","doi-asserted-by":"crossref","first-page":"1851.e1","DOI":"10.1016\/j.jtcvs.2018.11.099","article-title":"Cluster analysis of preoperative echocardiographic findings and outcomes following left ventricular device implantation.","volume":"157","author":"Tang","year":"2019","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R8-20250530","doi-asserted-by":"crossref","first-page":"1841.e1","DOI":"10.1016\/j.jtcvs.2018.12.071","article-title":"Mitral valve repair for severe mitral valve regurgitation during left ventricular assist device implantation.","volume":"157","author":"Pawale","year":"2019","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R9-20250530","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.athoracsur.2016.06.078","article-title":"Surgically corrected mitral regurgitation during left ventricular assist device implantation is associated with low recurrence rate and improved midterm survival.","volume":"103","author":"Tanaka","year":"2017","journal-title":"Ann Thorac Surg"},{"key":"R10-20250530","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/j.healun.2013.06.004","article-title":"Pre-operative echocardiographic features associated with persistent mitral regurgitation after left ventricular assist device implantation.","volume":"32","author":"Kitada","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R11-20250530","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1111\/aor.13295","article-title":"Impact of concomitant mitral valve surgery with LVAD placement: Systematic review and meta-analysis.","volume":"42","author":"Choi","year":"2018","journal-title":"Artif Organs"},{"key":"R12-20250530","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1080\/02841850802415544","article-title":"Estimation of ejection fraction and stroke volume using single- and biplane magnetic resonance imaging of the left cardiac ventricle.","volume":"49","author":"Thunberg","year":"2008","journal-title":"Acta Radiol"},{"key":"R13-20250530","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1161\/01.CIR.60.4.760","article-title":"Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques.","volume":"60","author":"Folland","year":"1979","journal-title":"Circulation"},{"key":"R14-20250530","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1161\/CIRCIMAGING.113.000690","article-title":"Size matters! Impact of age, sex, height, and weight on the normal heart size.","volume":"6","author":"Pfaffenberger","year":"2013","journal-title":"Circ Cardiovasc Imaging"},{"key":"R15-20250530","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1186\/1471-2288-14-113","article-title":"A comparison of three clustering methods for finding subgroups in MRI, SMS or clinical data: SPSS TwoStep Cluster analysis, Latent Gold and SNOB.","volume":"14","author":"Kent","year":"2014","journal-title":"BMC Med Res Methodol"},{"key":"R16-20250530","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1111\/1541-0420.00062","article-title":"A Bayesian approach for joint modeling of cluster size and subunit-specific outcomes.","volume":"59","author":"Dunson","year":"2003","journal-title":"Biometrics"},{"key":"R18-20250530","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1093\/comjnl\/41.8.578","article-title":"How many clusters? Which clustering method? Answers via model-based cluster analysis.","volume":"41","author":"Fraley","year":"1998","journal-title":"Comput J"},{"key":"R19-20250530","doi-asserted-by":"crossref","first-page":"2465","DOI":"10.1016\/j.jacc.2019.02.061","article-title":"Atrial functional mitral regurgitation: JACC review topic of the week.","volume":"73","author":"Deferm","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"R20-20250530","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1111\/jocs.12214","article-title":"Continuous flow left ventricular assist device implant significantly improves pulmonary hypertension, right ventricular contractility, and tricuspid valve competence.","volume":"28","author":"Atluri","year":"2013","journal-title":"J Card Surg"},{"key":"R21-20250530","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.jchf.2016.09.014","article-title":"Significance of residual mitral regurgitation after continuous flow left ventricular assist device implantation.","volume":"5","author":"Kassis","year":"2017","journal-title":"JACC Heart Fail"},{"key":"R22-20250530","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1016\/j.healun.2016.12.004","article-title":"Left ventricular assist device outcomes based on flow configuration and pre-operative left ventricular dimension: An interagency registry for mechanically assisted circulatory support analysis.","volume":"36","author":"Shah","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"R23-20250530","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1097\/MAT.0b013e31829be026","article-title":"Mitral valve repair at the time of continuous-flow left ventricular assist device implantation confers meaningful decrement in pulmonary vascular resistance.","volume":"59","author":"Taghavi","year":"2013","journal-title":"ASAIO J"},{"key":"R24-20250530","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1007\/s13239-016-0261-2","article-title":"Mitral valve regurgitation in the LVAD-assisted heart studied in a mock circulatory loop.","volume":"7","author":"May-Newman","year":"2016","journal-title":"Cardiovasc Eng Technol"},{"key":"R25-20250530","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1177\/1089253218788081","article-title":"Mitral intervention with LVAD: Preparing for recovery.","volume":"23","author":"Maxwell","year":"2019","journal-title":"Semin Cardiothorac Vasc Anesth"},{"key":"R26-20250530","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jchf.2015.10.001","article-title":"Hemodynamic ramp tests in patients with left ventricular assist devices.","volume":"4","author":"Uriel","year":"2016","journal-title":"JACC Heart Fail"},{"key":"R27-20250530","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1111\/j.1525-1594.2011.01276.x","article-title":"Effect of pulsatility on the mathematical modeling of rotary blood pumps.","volume":"35","author":"Pirbodaghi","year":"2011","journal-title":"Artif Organs"},{"key":"R28-20250530","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/MAT.0000000000000055","article-title":"Do axial-flow LVADs unload better than centrifugal-flow LVADs?","volume":"60","author":"Giridharan","year":"2014","journal-title":"ASAIO J"},{"key":"R29-20250530","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1111\/aor.12593","article-title":"Investigation of the characteristics of HeartWare HVAD and Thoratec HeartMate II under steady and pulsatile flow conditions.","volume":"40","author":"Noor","year":"2016","journal-title":"Artif Organs"},{"key":"R30-20250530","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/j.echo.2015.05.008","article-title":"Echocardiography in the management of patients with left ventricular assist devices: Recommendations from the American Society of Echocardiography.","volume":"28","author":"Stainback","year":"2015","journal-title":"J Am Soc Echocardiogr"},{"key":"R31-20250530","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.jchf.2015.03.003","article-title":"Echocardiography and continuous-flow left ventricular assist devices: Evidence and limitations.","volume":"3","author":"Cohen","year":"2015","journal-title":"JACC Heart Fail"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MAT.0000000000001379","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T16:04:50Z","timestamp":1748621090000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MAT.0000000000001379"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,4]]},"references-count":30,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000001379","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2,4]]}}}