{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T16:22:20Z","timestamp":1795018940353,"version":"4.10.1"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,7]]},"abstract":"<jats:p>National trends show rapid increases in the use of mechanical circulatory support devices (MCSD) over the last 20 years. While current literature has not proven a mortality benefit in cardiogenic shock as a complication of acute myocardial infarction (AMI-CS) with percutaneous MCSD, these devices are vital to maximizing cardiopulmonary parameters for definitive therapy. To minimize complications, many different techniques have been described including a novel off-pump direct apical cannulation for venoarterial-extracorporeal membrane oxygenation (VA-ECMO). This technique allows early ambulation and avoids peripheral artery access complications but has only been described in small case series. Our case series represents the largest summary of patients (50) using this technique and contains the only comparison data to date. Fifty-four percentage of our patients were Society for Cardiovascular Angiography and Interventions (SCAI) stage D and 22% were arrested before cannulation. We achieved flows on average &gt;5\u2009L\/min and most patients required biventricular drainage (86%) and an oxygenator (92%). Thirty day survival was 56% and most survivors were bridged to heart transplant (30%). Our most common complication was bleeding (16%). This technique showed significant improvement in ejection fraction (EF), cardiac output\/index (CO\/CI), and pulmonary artery pressures. This case series demonstrates the safety and efficacy of this novel technique for central cannulation in cardiogenic shock at large scale within a single institution.<\/jats:p>","DOI":"10.1097\/mat.0000000000002157","type":"journal-article","created":{"date-parts":[[2024,7,1]],"date-time":"2024-07-01T15:40:40Z","timestamp":1719848440000},"page":"565-569","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Direct Apical Cannulation With Protek Duo Rapid Deployment Cannula via Mini Thoracotomy for Ambulatory Venoarterial-Extracorporeal Membrane Oxygenation"],"prefix":"10.1097","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4196-5189","authenticated-orcid":false,"given":"Jared","family":"Cappelli","sequence":"first","affiliation":[{"name":"Department of General Surgery, University of Tennessee Health and Science Center - Nashville, Nashville, Tennessee"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1938-2793","authenticated-orcid":false,"given":"Jonathan","family":"Emling","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Ascension Saint Thomas Hospital West, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amber","family":"Edwards","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Ascension Saint Thomas Hospital West, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashok","family":"Babu","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Ascension Saint Thomas Hospital West, Nashville, Tennessee."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,2,5]]},"reference":[{"key":"R1-20250530","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1016\/j.jacc.2014.07.958","article-title":"National trends in the utilization of short-term mechanical circulatory support.","volume":"64","author":"Stretch","year":"2014","journal-title":"JACC"},{"key":"R2-20250530","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1161\/CIRCULATIONAHA.118.038201","article-title":"Intraaortic balloon pump in cardiogenic shock complicating acute myocardial infarction.","volume":"139","author":"Thiele","year":"2019","journal-title":"Circulation"},{"key":"R3-20250530","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1093\/eurheartj\/eht248","article-title":"Mechanical circulatory support in cardiogenic shock.","volume":"35","author":"Werdan","year":"2014","journal-title":"Eur Heart J"},{"key":"R4-20250530","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1161\/CIRCINTERVENTIONS.116.004337","article-title":"Percutaneous mechanical circulatory support devices in cardiogenic shock.","volume":"10","author":"Mandawat","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"key":"R5-20250530","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1161\/CIRCHEARTFAILURE.113.000271","article-title":"Bridge-to-decision therapy with continuous-flow external ventricular assist device in refractory cardiogenic shock of various causes.","volume":"7","author":"Takayama","year":"2014","journal-title":"Circ Heart Fail"},{"key":"R6-20250530","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.healun.2010.10.016","article-title":"Clinical outcomes for continuous-flow left ventricular assist device patients stratified by pre-operative INTERMACS classification.","volume":"30","author":"Boyle","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"R7-20250530","doi-asserted-by":"crossref","first-page":"1608","DOI":"10.1016\/j.athoracsur.2011.06.093","article-title":"Predictors of mortality after short-term ventricular assist device placement.","volume":"92","author":"Worku","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"R8-20250530","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.jtcvs.2010.03.046","article-title":"Outcomes of multicenter trial of the levitronix CentriMag ventricular assist system for short-term circulatory support.","volume":"141","author":"John","year":"2011","journal-title":"J Thor Cardiovasc Surg"},{"key":"R9-20250530","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1097\/MAT.0000000000000893","article-title":"Adverse event profile associated with prolonged use of centrimag ventricular assist device for refractory cardiogenic shock.","volume":"65","author":"Cevasco","year":"2019","journal-title":"ASAIO J"},{"key":"R10-20250530","doi-asserted-by":"crossref","first-page":"E477","DOI":"10.1532\/HSF98.20041068","article-title":"The CentriMag: A new optimized centrifugal blood pump with levitating impeller.","volume":"7","author":"Mueller","year":"2004","journal-title":"Heart Surg Forum"},{"key":"R11-20250530","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.1016\/j.athoracsur.2019.08.040","article-title":"Venoarterial-extracorporeal membrane oxygenation without routine systemic anticoagulation decreases adverse events.","volume":"109","author":"Wood","year":"2020","journal-title":"Ann Thorac Surg"},{"key":"R12-20250530","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.jtcvs.2010.04.028","article-title":"Less invasive left ventricular assist device placement for difficult resternotomy.","volume":"14","author":"Takayama","year":"2010","journal-title":"J Thor Cardiovasc Surg"},{"key":"R13-20250530","first-page":"591","article-title":"Novel minimally invasive surgical approach using an external ventricular assist device and extracorporeal membrane oxygenation in refractory cardiogenic shock.","volume":"51","author":"Takeda","year":"2016","journal-title":"Eur J Cardiothoracic Surg"},{"key":"R14-20250530","doi-asserted-by":"crossref","first-page":"44","DOI":"10.21037\/acs.2018.08.03","article-title":"Awake and fully mobile patients on cardiac extracorporeal life support.","volume":"8","author":"Abrams","year":"2019","journal-title":"Ann Cardiothorac Surg"},{"key":"R15-20250530","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1016\/j.jtcvs.2012.08.070","article-title":"Outcomes of axillary artery side graft cannulation for extracorporeal membrane oxygenation.","volume":"145","author":"Chamogeorgakis","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R16-20250530","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1111\/aor.12880","article-title":"Cannulation-related complications on veno-arterial extracorporeal membrane oxygenation: prevalence and effect on mortality.","volume":"41","author":"Wong","year":"2017","journal-title":"Artif Organs"},{"key":"R17-20250530","doi-asserted-by":"crossref","first-page":"2181","DOI":"10.1017\/S1047951122004073","article-title":"Harlequin effect and central veno-arterial extracorporeal life support.","volume":"33","author":"Prabhu","year":"2023","journal-title":"Cardiol Young"},{"key":"R18-20250530","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1177\/0267659118787426","article-title":"Protracted aortic valve closure during peripheral veno-arterial extracorporeal life support: Is intra-aortic balloon pump an effective solution?","volume":"34","author":"Meani","year":"2019","journal-title":"Perfusion"},{"key":"R19-20250530","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1051\/ject\/201345183","article-title":"Regional variation in arterial saturation and oxygen delivery during venoarterial extracorporeal membrane oxygenation.","volume":"45","author":"Avgerinos","year":"2013","journal-title":"J Extra Corpor Technol"},{"key":"R20-20250530","doi-asserted-by":"crossref","first-page":"1569","DOI":"10.1111\/jocs.15232","article-title":"A mini-thoracotomy approach for walking veno-arterial extracorporeal membranous oxygenation.","volume":"36","author":"Jeng","year":"2020","journal-title":"J Card Surg"},{"key":"R21-20250530","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1002\/ccd.27428","article-title":"Ambulatory central VA-ECMO with biventricular decompression for acute cardiogenic shock.","volume":"92","author":"Rao","year":"2018","journal-title":"Cath Card Interv"},{"key":"R22-20250530","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.1111\/jocs.14775","article-title":"Protek duo rapid deployment cannulation utilized to bridge to durable heartware left ventricular assist device.","volume":"35","author":"Ghannam","year":"2020","journal-title":"J Card Surg"},{"key":"R23-20250530","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1097\/MAT.0000000000001404","article-title":"Minimally invasive off-pump technique for temporary left ventricular support.","volume":"68","author":"Lima","year":"2022","journal-title":"ASAIO J"},{"key":"R24-20250530","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1016\/j.jacc.2022.01.018","article-title":"SCAI SHOCK stage classification expert consensus update: A review and incorporation of validation studies.","volume":"79","author":"Naidu","year":"2022","journal-title":"J Am Coll Cardiol"},{"key":"R25-20250530","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1513\/AnnalsATS.201510-717OC","article-title":"The ICU mobility scale has construct and predictive validity and is responsive. A multicenter observational study.","volume":"13","author":"Tipping","year":"2016","journal-title":"Ann Am Thorac Soc"},{"key":"R26-20250530","doi-asserted-by":"crossref","first-page":"2390","DOI":"10.3390\/jcm11092390","article-title":"Vasoactive inotropic score as a prognostic factor during (cardio-) respiratory ECMO.","volume":"11","author":"Sandrio","year":"2022","journal-title":"J Clin Med"},{"key":"R27-20250530","first-page":"40","article-title":"Vasoactive inotropic score as a predictor of mortality in adult patients with cardiogenic shock.","volume":"72","author":"Na","year":"2018","journal-title":"J Am Coll of Card"},{"key":"R28-20250530","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1097\/PCC.0b013e3181b806fc","article-title":"Vasoactive\u2013inotropic score as a predictor of morbidity and mortality in infants after cardiopulmonary bypass.","volume":"11","author":"Gaies","year":"2010","journal-title":"Pediatr Crit Care Med"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MAT.0000000000002157","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T13:01:40Z","timestamp":1748610100000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MAT.0000000000002157"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,5]]},"references-count":28,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000002157","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2,5]]}}}