{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T08:05:32Z","timestamp":1778659532121,"version":"3.51.4"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:p>The most common means of sternal closure after sternotomy is stainless steel wire cerclage. These wires, while inexpensive and simple in design, are known to be associated with low strength and sternal dehiscence. In this biomechanical analysis, we compare single sternal wires, double sternal wires, and a novel sternal closure device we have designed to mitigate sternal dehiscence. The device uses polymer grommets at the sternal interfaces to distribute load over a large surface area of bone. Samples of each closure device were installed in a bone model and distracted at a rate of 10\u2009mm\/min while tensile forces were continuously measured and compared. Single wires generated the lowest stiffness and strength values, followed by the double wires. The novel device demonstrated significantly higher stiffness and strength at all displacements compared with the single and double wires. Clinical use of this device may result in meaningful reduction in complications associated with the use of standard sternal wires such as sternal separation and fracture.<\/jats:p>","DOI":"10.1097\/mat.0000000000002185","type":"journal-article","created":{"date-parts":[[2024,3,11]],"date-time":"2024-03-11T23:00:06Z","timestamp":1710198006000},"page":"767-772","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Mechanical Analysis of a Novel Sternal Closure System in Static Tensile Loading"],"prefix":"10.1097","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6751-2911","authenticated-orcid":false,"given":"Gardner","family":"Yost","sequence":"first","affiliation":[{"name":"Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan"},{"name":"Department of Biomedical Engineering, Coulter Translational Research Partnership, University of Michigan, Ann Arbor, Michigan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeffrey","family":"Plott","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Coulter Translational Research Partnership, University of Michigan, Ann Arbor, Michigan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amogh","family":"Angandi","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Coulter Translational Research Partnership, University of Michigan, Ann Arbor, Michigan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Conor","family":"Locke","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Marten","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Coulter Translational Research Partnership, University of Michigan, Ann Arbor, Michigan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan W.","family":"Haft","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,3,11]]},"reference":[{"key":"R1-20250530","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1177\/096721090201000203","article-title":"Primary closure of median sternotomy: Techniques and principles.","volume":"10","author":"Losanoff","year":"2002","journal-title":"Cardiovasc Surg"},{"key":"R2-20250530","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1016\/S1010-7940(02)00124-0","article-title":"Disruption and infection of median sternotomy: a comprehensive review.","volume":"21","author":"Losanoff","year":"2002","journal-title":"Eur J Cardiothorac Surg"},{"key":"R3-20250530","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/S0003-4975(03)01468-1","article-title":"Biomechanical comparison of median sternotomy closures.","volume":"77","author":"Losanoff","year":"2004","journal-title":"Ann Thorac Surg"},{"key":"R4-20250530","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1615\/CritRevBiomedEng.2019026453","article-title":"Rationale and options for choosing an optimal closure technique for primary midsagittal osteochondrotomy of the sternum, part 2: a theoretical and critical review of techniques and fixation devices.","volume":"47","author":"Gandhi","year":"2019","journal-title":"Crit Rev Biomed Eng"},{"key":"R5-20250530","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1177\/0885328213495426","article-title":"A review of sternal closure techniques.","volume":"28","author":"Alhalawani","year":"2013","journal-title":"J Biomater Appl"},{"key":"R6-20250530","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/j.athoracsur.2005.03.089","article-title":"In vitro comparison of wire and plate fixation for midline sternotomies.","volume":"80","author":"Pai","year":"2005","journal-title":"Ann Thorac Surg"},{"key":"R7-20250530","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.1016\/j.athoracsur.2007.05.023","article-title":"Single wire versus double wire loops for median sternotomy closure: experimental biomechanical study using a human cadaveric model.","volume":"84","author":"Losanoff","year":"2007","journal-title":"Ann Thorac Surg"},{"key":"R8-20250530","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1093\/icvts\/ivu184","article-title":"Mechanism of sternotomy dehiscence.","volume":"19","author":"Casha","year":"2014","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"R9-20250530","doi-asserted-by":"crossref","first-page":"104017","DOI":"10.1016\/j.medengphy.2023.104017","article-title":"Biomechanical properties of artificial bones made by sawbones: a review.","volume":"118","author":"Zdero","year":"2023","journal-title":"Med Eng Phys"},{"key":"R10-20250530","first-page":"753","article-title":"The median sternal incision in intracardiac surgery with extra-corporeal circulation: a general evaluation of its use in heart surgery.","volume":"42","author":"Julian","year":"1957","journal-title":"Surgery"},{"key":"R11-20250530","doi-asserted-by":"crossref","first-page":"1854","DOI":"10.1016\/j.athoracsur.2012.07.085","article-title":"Sternal closure with rigid plate fixation versus wire closure: a randomized controlled multicenter trial.","volume":"94","author":"Raman","year":"2012","journal-title":"Ann Thorac Surg"},{"key":"R12-20250530","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1016\/S0022-5223(99)70251-5","article-title":"Mechanical analysis of midline sternotomy wound closure.","volume":"117","author":"McGregor","year":"1999","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MAT.0000000000002185","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T13:06:26Z","timestamp":1748610386000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MAT.0000000000002185"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,11]]},"references-count":12,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000002185","relation":{},"ISSN":["1058-2916","1538-943X"],"issn-type":[{"value":"1058-2916","type":"print"},{"value":"1538-943X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,11]]}}}