{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,31]],"date-time":"2025-05-31T04:07:53Z","timestamp":1748664473178,"version":"3.41.0"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:p>This study aimed to explore the potential impact of the angular position of the outflow graft on thromboembolic events and aortic valve regurgitation in people with a left ventricular assist device (LVAD). We analyzed contrast computed tomography (CT) data of patients with LVAD implantation between 2016 and 2021. Three-dimensional reconstructions of the outflow graft and aortic arch were performed to calculate the horizontal (azimuth) angle and vertical (polar) angle, as well as the relative distance between the outflow graft, aortic valve, and brachiocephalic artery. Among 59 patients (median age 57, 68% male), a vertical angle \u2265107\u00b0 correlated significantly with increased cerebrovascular accidents (hazard ratio [HR]: 5.8, 95% confidence interval [CI]: 1.3\u201326.3, <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.022) and gastrointestinal bleeding (HR: 3.4, 95% CI: 1.0\u201311.2, <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.049) during a median 25 month follow-up. No significant differences were found between the vertical angle and aortic valve regurgitation or survival. The horizontal angle and relative distance did not show differences regarding clinical adverse events. This study emphasizes the importance of the LVAD outflow graft angular position to prevent life-threatening thromboembolic events. This study suggests the need for prospective research to further validate these findings.<\/jats:p>","DOI":"10.1097\/mat.0000000000002189","type":"journal-article","created":{"date-parts":[[2024,4,10]],"date-time":"2024-04-10T08:00:10Z","timestamp":1712736010000},"page":"861-867","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Influence of the Outflow Graft Angular Position on the Outcomes in Patients With a Left Ventricular Assist Device"],"prefix":"10.1097","volume":"70","author":[{"given":"Casper F.","family":"Zijderhand","sequence":"first","affiliation":[{"name":"Thoraxcenter, Department of Cardiothoracic Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jette J.","family":"Peek","sequence":"additional","affiliation":[{"name":"Thoraxcenter, Department of Cardiothoracic Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jelena","family":"Sjatskig","sequence":"additional","affiliation":[{"name":"Thoraxcenter, Department of Cardiothoracic Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olivier C.","family":"Manintveld","sequence":"additional","affiliation":[{"name":"Thoraxcenter, Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos A.","family":"Bekkers","sequence":"additional","affiliation":[{"name":"Thoraxcenter, Department of Cardiothoracic Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ad J. J. C.","family":"Bogers","sequence":"additional","affiliation":[{"name":"Thoraxcenter, Department of Cardiothoracic Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3293-9261","authenticated-orcid":false,"given":"Kadir","family":"Caliskan","sequence":"additional","affiliation":[{"name":"Thoraxcenter, Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,4,8]]},"reference":[{"key":"R1-20250530","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1056\/NEJMoa1900486","article-title":"A fully magnetically levitated left ventricular assist device\u2014Final report.","volume":"380","author":"Mehra","year":"2019","journal-title":"N Engl J Med"},{"key":"R2-20250530","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1056\/NEJMoa067758","article-title":"Use of a continuous-flow device in patients awaiting heart transplantation.","volume":"357","author":"Miller","year":"2007","journal-title":"N Engl J Med"},{"key":"R3-20250530","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.athoracsur.2020.12.038","article-title":"The Society of Thoracic Surgeons Intermacs 2020 annual report.","volume":"111","author":"Molina","year":"2021","journal-title":"Ann Thorac Surg"},{"key":"R4-20250530","doi-asserted-by":"crossref","first-page":"1826","DOI":"10.1016\/j.jacc.2009.12.052","article-title":"Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients.","volume":"55","author":"Rogers","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"R5-20250530","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1111\/aor.13755","article-title":"Optimal cannula positioning of HeartMate 3 left ventricular assist device.","volume":"44","author":"Imamura","year":"2020","journal-title":"Artif Organs"},{"key":"R6-20250530","doi-asserted-by":"crossref","first-page":"ezac415","DOI":"10.1093\/ejcts\/ezac415","article-title":"Relapsing low-flow alarms due to suboptimal alignment of the left ventricular assist device inflow cannula.","volume":"62","author":"Zijderhand","year":"2022","journal-title":"Eur J Cardiothorac Surg"},{"key":"R7-20250530","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.healun.2013.12.002","article-title":"The vexing problem of thrombosis in long-term mechanical circulatory support.","volume":"33","author":"Mehra","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"R8-20250530","doi-asserted-by":"crossref","first-page":"1226","DOI":"10.1007\/s10439-022-03127-4","article-title":"Quantitative assessment of aortic hemodynamics for varying left ventricular assist device outflow graft angles and flow pulsation.","volume":"51","author":"Sahni","year":"2023","journal-title":"Ann Biomed Eng"},{"key":"R9-20250530","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1007\/s10439-010-9905-9","article-title":"Towards non-thrombogenic performance of blood recirculating devices.","volume":"38","author":"Bluestein","year":"2010","journal-title":"Ann Biomed Eng"},{"key":"R10-20250530","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1097\/MAT.0000000000000443","article-title":"LVAD outflow graft angle and thrombosis risk.","volume":"63","author":"Aliseda","year":"2017","journal-title":"ASAIO J"},{"key":"R11-20250530","doi-asserted-by":"crossref","first-page":"e004325","DOI":"10.1161\/CIRCHEARTFAILURE.117.004325","article-title":"Left ventricular assist device inflow cannula angle and thrombosis risk.","volume":"11","author":"Chivukula","year":"2018","journal-title":"Circ Heart Fail"},{"key":"R12-20250530","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1111\/aor.13705","article-title":"The influence of left ventricular assist device inflow cannula position on thrombosis risk.","volume":"44","author":"Ghodrati","year":"2020","journal-title":"Artif Organs"},{"key":"R13-20250530","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1080\/10255842.2011.629616","article-title":"Computational fluid dynamics analysis of surgical adjustment of left ventricular assist device implantation to minimise stroke risk.","volume":"16","author":"Osorio","year":"2013","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R14-20250530","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1177\/03913988231154284","article-title":"Outflow cannula alignment in continuous flow left ventricular devices is associated with stroke.","volume":"46","author":"Kassi","year":"2023","journal-title":"Int J Artif Organs"},{"key":"R15-20250530","doi-asserted-by":"crossref","first-page":"e02700","DOI":"10.1002\/cnm.2700","article-title":"A computational fluid dynamics comparison between different outflow graft anastomosis locations of Left Ventricular Assist Device (LVAD) in a patient-specific aortic model.","volume":"31","author":"Caruso","year":"2015","journal-title":"Int J Numer Method Biomed Eng"},{"key":"R16-20250530","first-page":"294","article-title":"The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling.","volume":"32","author":"Kar","year":"2005","journal-title":"Tex Heart Inst J"},{"key":"R17-20250530","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/j.healun.2005.11.451","article-title":"Is native aortic valve commissural fusion in patients with long-term left ventricular assist devices associated with clinically important aortic insufficiency?","volume":"25","author":"Letsou","year":"2006","journal-title":"J Heart Lung Transplant"},{"key":"R18-20250530","doi-asserted-by":"crossref","first-page":"1270","DOI":"10.1016\/S0003-4975(00)01929-9","article-title":"Partial aortic valve fusion induced by left ventricular assist device.","volume":"70","author":"Rose","year":"2000","journal-title":"Ann Thorac Surg"},{"key":"R19-20250530","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1067\/mtc.2001.114770","article-title":"Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: Signs, symptoms, and concerns.","volume":"122","author":"Samuels","year":"2001","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R20-20250530","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.athoracsur.2012.09.020","article-title":"The development of aortic insufficiency in continuous-flow left ventricular assist device-supported patients.","volume":"95","author":"Aggarwal","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"R21-20250530","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1007\/s10047-017-1006-1","article-title":"Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support.","volume":"21","author":"Iizuka","year":"2018","journal-title":"J Artif Organs"},{"key":"R22-20250530","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1016\/j.healun.2010.05.018","article-title":"Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices.","volume":"29","author":"Pak","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R23-20250530","first-page":"701","article-title":"Heyde\u2019s syndrome: A review.","volume":"13","author":"Pate","year":"2004","journal-title":"J Heart Valve Dis"},{"key":"R24-20250530","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1016\/j.ejcts.2007.12.047","article-title":"Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease.","volume":"33","author":"Geisen","year":"2008","journal-title":"Eur J Cardiothorac Surg"},{"key":"R25-20250530","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1016\/j.healun.2016.05.019","article-title":"Evaluation of von Willebrand factor with a fully magnetically levitated centrifugal continuous-flow left ventricular assist device in advanced heart failure.","volume":"35","author":"Netuka","year":"2016","journal-title":"J Heart Lung Transplant"},{"key":"R26-20250530","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1016\/j.jacc.2010.05.016","article-title":"Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation.","volume":"56","author":"Uriel","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"R27-20250530","doi-asserted-by":"crossref","first-page":"e008034","DOI":"10.1161\/CIRCHEARTFAILURE.120.008034","article-title":"Patient-specific computational fluid dynamics reveal localized flow patterns predictive of post-left ventricular assist device aortic incompetence.","volume":"14","author":"Shad","year":"2021","journal-title":"Circ Heart Fail"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MAT.0000000000002189","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T13:00:34Z","timestamp":1748610034000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MAT.0000000000002189"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,8]]},"references-count":27,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000002189","relation":{},"ISSN":["1058-2916","1538-943X"],"issn-type":[{"type":"print","value":"1058-2916"},{"type":"electronic","value":"1538-943X"}],"subject":[],"published":{"date-parts":[[2024,4,8]]}}}