{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:33:42Z","timestamp":1786120422962,"version":"build-2736575974"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>\n                    To optimize and evaluate the hydrodynamic performance and gas exchange efficiency of a newly developed centrifugal blood pump and membrane oxygenator for extracorporeal membrane oxygenation (ECMO) support, blood pump and oxygenator designs were optimized from a hydrodynamic perspective by adopting a five-blade impeller for the pump and a circular flow path with a central inlet and bottom outlet for the oxygenator. Computational fluid dynamics (CFD) was used to evaluate shear distribution.\n                    <jats:italic toggle=\"yes\">In vitro<\/jats:italic>\n                    experiments assessed pressure-flow characteristics. Long-term ECMO support (14 days) was performed in sheep using both venovenous (VV) and venoarterial (VA) modes. Key parameters, including plasma-free hemoglobin and comprehensive blood tests (biochemistry, coagulation, platelet function), were analyzed. Computational fluid dynamics revealed uniform pump flow with minimal high-shear volume and negligible stagnation in the oxygenator, indicating low hemolysis and thrombosis risk.\n                    <jats:italic toggle=\"yes\">In vitro<\/jats:italic>\n                    , the oxygenator showed lower transmembrane pressure than Quadrox-PLS across 1\u20137\u2009L\/min and higher O\n                    <jats:sub>2<\/jats:sub>\n                    transfer (1\u20133\u2009L\/min).\n                    <jats:italic toggle=\"yes\">In vivo<\/jats:italic>\n                    , circuit flow was stable (2.2\u2009L\/min [VV], 2.5\u2009L\/min [VA]) and oxygenator \u0394\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    remained 10\u201312\u2009mm Hg with stable oxygen exchange (155\u2009ml\/min [VV], 165\u2009ml\/min [VA]), and plasma-free hemoglobin (pfHb) remained below 50\u2009mg\/dL. Three non\u2013device-related deaths occurred, and there were no device-related thrombotic or hemorrhagic complications. The ECMO system demonstrated excellent mechanical stability, effective long-term oxygenation, favorable hemodynamic performance, and outstanding hemocompatibility in large-animal models.\n                  <\/jats:p>","DOI":"10.1097\/mat.0000000000002810","type":"journal-article","created":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T20:42:47Z","timestamp":1786048967000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A Novel Extracorporeal Membrane Oxygenation System With Enhanced Hemocompatibility and Long-Term Stability"],"prefix":"10.1097","author":[{"given":"Hongyu","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheng","family":"Liu","sequence":"additional","affiliation":[{"name":"National Center for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Beijing, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zejian","family":"Jin","sequence":"additional","affiliation":[{"name":"National Center for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Beijing, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yawei","family":"Wang","sequence":"additional","affiliation":[{"name":"Aerospace Changfeng Medical Technology (Chengdu) Co., Ltd. Chengdu, China; and"},{"name":"Beijing Aerospace Changfeng Co., Ltd, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinian","family":"Li","sequence":"additional","affiliation":[{"name":"Beijing Aerospace Changfeng Co., Ltd, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huichao","family":"Liu","sequence":"additional","affiliation":[{"name":"Beijing Aerospace Changfeng Co., Ltd, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenbo","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenlu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mengqi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingji","family":"Fu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yubo","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3716-3156","authenticated-orcid":false,"given":"Zengsheng","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,6]]},"reference":[{"key":"R1-20260806","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1051\/ject\/2023047","article-title":"Improving ECMO therapy: Monitoring oxygenator functionality and identifying key indicators, factors, and considerations for changeout.","volume":"56","author":"Butt","year":"2024","journal-title":"J Extra Corpor Technol"},{"key":"R2-20260806","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1111\/aor.13513","article-title":"Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients?","volume":"43","author":"Steiger","year":"2019","journal-title":"Artif Organs"},{"key":"R3-20260806","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.tmrv.2014.12.001","article-title":"Extracorporeal membrane oxygenation-hemostatic complications.","volume":"29","author":"Murphy","year":"2015","journal-title":"Transfus Med Rev"},{"key":"R4-20260806","doi-asserted-by":"crossref","first-page":"27","DOI":"10.14797\/mdcj-16-1-27","article-title":"Acute mechanical circulatory support for cardiogenic shock.","volume":"16","author":"Telukuntla","year":"2020","journal-title":"Methodist Debakey Cardiovasc J"},{"key":"R5-20260806","first-page":"241524","article-title":"Platelet adhesion and activation in an ECMO thrombosis\u2010on\u2010a\u2010chip model.","volume":"11","author":"Goh","year":"2024","journal-title":"Adv Sci"},{"key":"R6-20260806","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.7150\/ijms.50217","article-title":"Hemolysis in patients with extracorporeal membrane oxygenation therapy for severe acute respiratory distress syndrome\u2014a systematic review of the literature.","volume":"18","author":"Materne","year":"2021","journal-title":"Int J Med Sci"},{"key":"R7-20260806","doi-asserted-by":"crossref","DOI":"10.1186\/s13054-016-1570-4","article-title":"The inflammatory response to extracorporeal membrane oxygenation (ECMO): A review of the pathophysiology.","volume":"20","author":"Millar","year":"2016","journal-title":"Crit Care"},{"key":"R8-20260806","doi-asserted-by":"crossref","first-page":"e0248645","DOI":"10.1371\/journal.pone.0248645","article-title":"Different mechanisms of oxygenator failure and high plasma von Willebrand factor antigen influence success and survival of venovenous extracorporeal membrane oxygenation.","volume":"16","author":"Steiger","year":"2021","journal-title":"PLoS One"},{"key":"R9-20260806","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1111\/ejh.13520","article-title":"Anticoagulation strategies in extracorporeal circulatory devices in adult populations.","volume":"106","author":"Kato","year":"2021","journal-title":"Eur J Haematol"},{"key":"R10-20260806","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1007\/s11239-021-02562-9","article-title":"Early platelet dysfunction in patients receiving extracorporeal membrane oxygenation is associated with mortality.","volume":"53","author":"Siegel","year":"2022","journal-title":"J Thromb Thrombolysis"},{"key":"R11-20260806","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1177\/0267659118824218","article-title":"Extracorporeal membrane oxygenation-induced fibrinolysis detected by rotational thromboelastometry and treated by oxygenator exchange.","volume":"34","author":"Durila","year":"2019","journal-title":"Perfusion"},{"key":"R12-20260806","doi-asserted-by":"crossref","first-page":"106907","DOI":"10.1016\/j.compbiomed.2023.106907","article-title":"Comparison of hemodynamic features and thrombosis risk of membrane oxygenators with different structures: A numerical study.","volume":"159","author":"Fu","year":"2023","journal-title":"Comput Biol Med"},{"key":"R13-20260806","article-title":"Beveled shaped axial oxygenator with improved hemodynamics.","author":"Franke","year":"2024","journal-title":"medRxiv"},{"key":"R14-20260806","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1111\/aor.14384","article-title":"Impact of volute design features on hemodynamic performance and hemocompatibility of centrifugal blood pumps used in ECMO.","volume":"47","author":"Li","year":"2023","journal-title":"Artif Organs"},{"key":"R15-20260806","doi-asserted-by":"crossref","first-page":"107379","DOI":"10.1016\/j.compbiomed.2023.107379","article-title":"Development and validation of a mathematical model for evaluating shear-induced damage of von Willebrand factor.","volume":"164","author":"Li","year":"2023","journal-title":"Comput Biol Med"},{"key":"R16-20260806","doi-asserted-by":"crossref","first-page":"e3671","DOI":"10.1002\/cnm.3671","article-title":"The impact of rotor configurations on hemodynamic features, hemocompatibility and dynamic balance of the centrifugal blood pump: a numerical study.","volume":"39","author":"Li","year":"2023","journal-title":"Int J Numer Method Biomed Eng"},{"key":"R18-20260806","doi-asserted-by":"crossref","first-page":"679","DOI":"10.21037\/atm-21-1135","article-title":"Hemodynamic evaluation and in vitro hemolysis evaluation of a novel centrifugal pump for extracorporeal membrane oxygenation.","volume":"9","author":"Fu","year":"2021","journal-title":"Ann Transl Med"},{"key":"R19-20260806","doi-asserted-by":"crossref","first-page":"e0124034","DOI":"10.1371\/journal.pone.0124034","article-title":"Plasma free hemoglobin is an independent predictor of mortality among patients on extracorporeal membrane oxygenation support.","volume":"10","author":"Omar","year":"2015","journal-title":"PLoS One"},{"key":"R20-20260806","doi-asserted-by":"crossref","first-page":"1584","DOI":"10.1016\/j.athoracsur.2012.01.008","article-title":"20-year experience of prolonged extracorporeal membrane oxygenation in critically ill children with cardiac or pulmonary failure.","volume":"93","author":"Gupta","year":"2012","journal-title":"Ann Thorac Surg"},{"key":"R21-20260806","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1097\/MAT.0000000000000538","article-title":"Efficacy of flow monitoring during ECMO.","volume":"63","author":"Badheka","year":"2017","journal-title":"ASAIO J"},{"key":"R22-20260806","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1111\/jth.14661","article-title":"Effect of blood flow on platelets, leukocytes, and extracellular vesicles in thrombosis of simulated neonatal extracorporeal circulation.","volume":"18","author":"Meyer","year":"2020","journal-title":"J Thromb Haemost"},{"key":"R23-20260806","doi-asserted-by":"crossref","first-page":"106271","DOI":"10.1016\/j.compbiomed.2022.106271","article-title":"Multi-indicator analysis of mechanical blood damage with five clinical ventricular assist devices.","volume":"151","author":"Li","year":"2022","journal-title":"Comput Biol Med"},{"key":"R24-20260806","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.thromres.2022.02.011","article-title":"Coagulation activation during extracorporeal membrane oxygenation (ECMO).","volume":"211","author":"Chandler","year":"2022","journal-title":"Thromb Res"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MAT.0000000000002810","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T20:42:50Z","timestamp":1786048970000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MAT.0000000000002810"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,6]]},"references-count":23,"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000002810","relation":{},"ISSN":["1058-2916","1538-943X"],"issn-type":[{"value":"1058-2916","type":"print"},{"value":"1538-943X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,6]]}}}