{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T21:09:55Z","timestamp":1788815395520,"version":"build-2803163510"},"reference-count":8,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Hypothermic oxygenated machine perfusion (HOPE) is increasingly applied in donation after circulatory death (DCD) kidney transplantation to improve graft preservation, enable functional assessment, and reduce organ discard. In DCD settings characterized by prolonged mandatory agonal and warm ischemia phases, graft susceptibility to ischemia\u2013reperfusion injury is amplified, rendering the preservation strategy particularly consequential. We describe a pragmatic technical workaround consisting of prolonged hypothermic perfusion of en bloc kidneys via aortic cannulation using a multiorgan perfusion system (VitaSmart Hypothermic Oxygenated Perfusion System, Bridge to Life Ltd., Northbrook, IL) operated under its standard renal perfusion settings. This approach allows continuous low-pressure perfusion, real-time monitoring, and the possibility of pharmacological intervention when renal-dedicated disposables are unavailable or when prolonged hypothermic preservation is required for logistical reasons. The technique was applied as a feasibility stress test in two DCD kidney grafts, which were perfused for 18 hours at controlled low pressure following an initial oxygenated flushing phase and maintained on continuous perfusion until implantation. The procedure proved technically stable and biologically informative, supporting its use as a rescue preservation strategy in selected DCD scenarios that require extended hypothermic oxygenated preservation and real-time graft assessment.<\/jats:p>","DOI":"10.1097\/mat.0000000000002844","type":"journal-article","created":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T21:00:20Z","timestamp":1788814820000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["En Bloc Kidney HOPE in DCD"],"prefix":"10.1097","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3987-9262","authenticated-orcid":false,"given":"Duilio","family":"Pagano","sequence":"first","affiliation":[{"name":"Abdominal Center Istituto di Ricovero e Cura a Carattere Scientifico \u2013 Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS ISMETT), Palermo, Italy"},{"name":"Division of Abdominal Surgery and Abdominal Organ Transplantation, University of Pittsburgh Medical Center (UPMC), Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kejd","family":"Bici","sequence":"additional","affiliation":[{"name":"Pediatric Surgery Unit, Department of Pediatrics, Istituto di Ricovero e Cura a Carattere Scientifico \u2013 Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS ISMETT), Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barbara","family":"Buscemi","sequence":"additional","affiliation":[{"name":"Abdominal Center Istituto di Ricovero e Cura a Carattere Scientifico \u2013 Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS ISMETT), Palermo, Italy"},{"name":"Division of Abdominal Surgery and Abdominal Organ Transplantation, University of Pittsburgh Medical Center (UPMC), Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silvia","family":"Leonello","sequence":"additional","affiliation":[{"name":"Abdominal Center Istituto di Ricovero e Cura a Carattere Scientifico \u2013 Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS ISMETT), Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Verville","sequence":"additional","affiliation":[{"name":"Medical School, Universit\u00e9 Laval, Quebec City, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gaetano","family":"Burgio","sequence":"additional","affiliation":[{"name":"Department of Anesthesia and Intensive Care, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT-IRCCS), Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9684-8035","authenticated-orcid":false,"given":"Salvatore","family":"Gruttadauria","sequence":"additional","affiliation":[{"name":"Abdominal Center Istituto di Ricovero e Cura a Carattere Scientifico \u2013 Mediterranean Institute for Transplantation and Advanced Specialized Therapies (IRCCS ISMETT), Palermo, Italy"},{"name":"Division of Abdominal Surgery and Abdominal Organ Transplantation, University of Pittsburgh Medical Center (UPMC), Palermo, Italy"},{"name":"Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,7]]},"reference":[{"key":"R1-20260907","doi-asserted-by":"crossref","first-page":"e70166","DOI":"10.1111\/ctr.70166","article-title":"Hypothermic oxygenated perfusion in extended criteria donor kidney transplantation: A randomized clinical trial.","volume":"39","author":"Dajti","year":"2025","journal-title":"Clin Transplant"},{"key":"R2-20260907","doi-asserted-by":"crossref","first-page":"S218","DOI":"10.1097\/01.tp.0000886484.38588.c2","article-title":"Hypothermic oxygenated machine perfusion of an en-bloc dual kidney specimen: Proof of concept, in an Animal DCD Model, of a new option to preserve and evaluate kidney grafts.","volume":"106","author":"Kauffmann","year":"2022","journal-title":"Transplantation"},{"key":"R3-20260907","doi-asserted-by":"crossref","first-page":"6063","DOI":"10.1038\/s41598-020-62979-9","article-title":"Hypothermic oxygenated new machine perfusion system in liver and kidney transplantation of extended criteria donors: First Italian clinical trial.","volume":"10","author":"Ravaioli","year":"2020","journal-title":"Sci Rep"},{"key":"R4-20260907","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1111\/aor.12836","article-title":"Effect of hypothermic machine perfusion on the preservation of kidneys donated after cardiac death: A single-center, randomized, controlled trial.","volume":"41","author":"Wang","year":"2017","journal-title":"Artif Organs"},{"key":"R5-20260907","doi-asserted-by":"crossref","first-page":"1927","DOI":"10.3390\/jcm14061927","article-title":"Does oxygen work? Evidence for oxygenation during kidney graft preservation: A review.","volume":"14","author":"Calva Lopez","year":"2025","journal-title":"J Clin Med"},{"key":"R6-20260907","doi-asserted-by":"crossref","first-page":"17726","DOI":"10.1038\/s41598-020-74839-7","article-title":"Decrease of renal resistance during hypothermic oxygenated machine perfusion is associated with early allograft function in extended criteria donation kidney transplantation.","volume":"10","author":"Meister","year":"2020","journal-title":"Sci Rep"},{"key":"R7-20260907","doi-asserted-by":"crossref","first-page":"15282","DOI":"10.3389\/ti.2025.15282","article-title":"Nationwide hypothermic machine perfusion for ECD and DCD kidney transplantation in Belgium: One-year outcomes and impact on transplant rates and budget impact analysis.","volume":"38","author":"Darius","year":"2025","journal-title":"Transpl Int"},{"key":"R8-20260907","doi-asserted-by":"crossref","first-page":"e256","DOI":"10.1097\/MAT.0000000000002503","article-title":"Normothermic machine perfusion and inflammatory mediators adsorption: First kidney transplant experience.","volume":"71","author":"Pagano","year":"2025","journal-title":"ASAIO J"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MAT.0000000000002844","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T21:00:22Z","timestamp":1788814822000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MAT.0000000000002844"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,7]]},"references-count":8,"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000002844","relation":{},"ISSN":["1058-2916","1538-943X"],"issn-type":[{"value":"1058-2916","type":"print"},{"value":"1538-943X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,7]]}}}