{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T21:58:41Z","timestamp":1790373521133,"version":"4.1.0"},"reference-count":8,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Thoracoabdominal normothermic regional perfusion (TA-NRP) is increasingly adopted for cardiac allograft procurement in controlled donation after circulatory death (cDCD). In settings where ante-mortem femoral guidewire placement is permitted, peripheral TA-NRP may be employed following declaration of death to enable rapid restoration of organ perfusion, reducing warm ischemic time and avoiding manipulation of the cardiac structures before procurement. However, the differential oxygenation that may develop in this setting can be dangerously unrecognized due to supra-aortic vessel occlusion and the resulting inability to monitor upper-body oxygenation as an estimation of blood oxygenation in the ascending aorta. This phenomenon may lead to impaired myocardial oxygenation, potentially resulting in primary graft dysfunction after transplantation or, alternatively, in the unnecessary discard of an otherwise suitable cardiac allograft. In order to detect and correct this phenomenon, we implemented a modification of the TA-NRP circuit by incorporating a continuous aortic root oxygenation monitoring device. Continuous monitoring proved crucial in two scenarios: first, by identifying differential oxygenation resolved by left ventricular unloading; and second, by detecting severe aortic root desaturation after TA-NRP discontinuation, undetectable by conventional upper-body oxygenation monitoring. This simple strategy may improve the safety and reliability of donor heart functional assessment during TA-NRP.<\/jats:p>","DOI":"10.1097\/mat.0000000000002865","type":"journal-article","created":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T21:00:08Z","timestamp":1790370008000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Differential Oxygenation During Peripheral Thoracoabdominal Normothermic Regional Perfusion in Controlled Donation After Circulatory Death: An Underrecognized Cause of Potential Allograft Dysfunction and Discard"],"prefix":"10.1097","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5586-619X","authenticated-orcid":false,"given":"Bleri","family":"Celmeta","sequence":"first","affiliation":[{"name":"From the Cardiac Surgery and Heart Transplantation Operative Unit, \u201cDe Gasperis\u201d Cardio Center, Thoraco-vascular Department, Niguarda Great Metropolitan Hospital, Milan, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Camilla","family":"Crepaldi","sequence":"additional","affiliation":[{"name":"From the Cardiac Surgery and Heart Transplantation Operative Unit, \u201cDe Gasperis\u201d Cardio Center, Thoraco-vascular Department, Niguarda Great Metropolitan Hospital, Milan, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mauro","family":"Bosi","sequence":"additional","affiliation":[{"name":"From the Cardiac Surgery and Heart Transplantation Operative Unit, \u201cDe Gasperis\u201d Cardio Center, Thoraco-vascular Department, Niguarda Great Metropolitan Hospital, Milan, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5250-1796","authenticated-orcid":false,"given":"Daniele","family":"Ronco","sequence":"additional","affiliation":[{"name":"From the Cardiac Surgery and Heart Transplantation Operative Unit, \u201cDe Gasperis\u201d Cardio Center, Thoraco-vascular Department, Niguarda Great Metropolitan Hospital, Milan, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mattia Maria","family":"Barbiero","sequence":"additional","affiliation":[{"name":"From the Cardiac Surgery and Heart Transplantation Operative Unit, \u201cDe Gasperis\u201d Cardio Center, Thoraco-vascular Department, Niguarda Great Metropolitan Hospital, Milan, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8206-3536","authenticated-orcid":false,"given":"Aldo","family":"Cannata","sequence":"additional","affiliation":[{"name":"From the Cardiac Surgery and Heart Transplantation Operative Unit, \u201cDe Gasperis\u201d Cardio Center, Thoraco-vascular Department, Niguarda Great Metropolitan Hospital, Milan, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5439-1420","authenticated-orcid":false,"given":"Claudio Francesco","family":"Russo","sequence":"additional","affiliation":[{"name":"From the Cardiac Surgery and Heart Transplantation Operative Unit, \u201cDe Gasperis\u201d Cardio Center, Thoraco-vascular Department, Niguarda Great Metropolitan Hospital, Milan, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,25]]},"reference":[{"key":"R1-20260925","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.1016\/j.healun.2025.05.007","article-title":"Two hundred cases of cardiac donation after circulatory death utilizing normothermic regional perfusion: The 4-year Vanderbilt experience.","volume":"44","author":"Williams","year":"2025","journal-title":"J Heart Lung Transplant"},{"key":"R2-20260925","doi-asserted-by":"crossref","first-page":"11","DOI":"10.21037\/acs-2024-dcd-0132","article-title":"Donation after circulatory death transplantation: A systematic review and meta-analysis of outcomes and methods of donation.","volume":"14","author":"Jolliffe","year":"2025","journal-title":"Ann Cardiothorac Surg"},{"key":"R3-20260925","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/j.healun.2020.03.020","article-title":"Donor heart and lung procurement: A consensus statement.","volume":"39","author":"Copeland","year":"2020","journal-title":"J Heart Lung Transplant"},{"key":"R4-20260925","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1055\/s-0033-1353475","article-title":"Basic vascular neuroanatomy of the brain and spine: What the general interventional radiologist needs to know.","volume":"30","author":"Prince","year":"2013","journal-title":"Semin Intervent Radiol"},{"key":"R5-20260925","first-page":"e172","article-title":"Evaluation of cerebral blood pressure during normothermic regional perfusion.","volume":"72","author":"Hoffman","year":"2026","journal-title":"ASAIO J"},{"key":"R6-20260925","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.jtcvs.2022.01.018","article-title":"Normothermic regional perfusion: Ethical issues in thoracic organ donation.","volume":"164","author":"Entwistle","year":"2022","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R7-20260925","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1051\/ject\/200537377","article-title":"Use of the CDI blood parameter monitoring system 500 for continuous blood gas measurement during extracorporeal membrane oxygenation simulation.","volume":"37","author":"Schreur","year":"2005","journal-title":"J Extra Corpor Technol"},{"key":"R8-20260925","article-title":"A totally beating heart transplant from donation after circulatory death and thoracoabdominal normothermic regional perfusion.","volume":"2026","author":"\u00c7elmeta","year":"2026","journal-title":"Multimed Man Cardiothorac Surg"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MAT.0000000000002865","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T21:00:09Z","timestamp":1790370009000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MAT.0000000000002865"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,25]]},"references-count":8,"URL":"https:\/\/doi.org\/10.1097\/mat.0000000000002865","relation":{},"ISSN":["1058-2916","1538-943X"],"issn-type":[{"value":"1058-2916","type":"print"},{"value":"1538-943X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,25]]}}}