{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:06:18Z","timestamp":1786118778933,"version":"build-2736575974"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2007,5]]},"DOI":"10.1097\/mat.0b013e318031af3b","type":"journal-article","created":{"date-parts":[[2007,5,18]],"date-time":"2007-05-18T17:49:44Z","timestamp":1179510584000},"page":"368-373","source":"Crossref","is-referenced-by-count":11,"title":["Evaluation of Fiber Bundle Rotation for Enhancing Gas Exchange in a Respiratory Assist Catheter"],"prefix":"10.1097","volume":"53","author":[{"given":"Heide J.","family":"Eash","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin M.","family":"Mihelc","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian J.","family":"Frankowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brack G.","family":"Hattler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William J.","family":"Federspiel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-19-20210129","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1111\/j.1525-1594.1994.tb03331.x","article-title":"Permissive hypercapnia and intravascular oxygenator in the treatment of patients with ARDS.","volume":"18","author":"Brunet","year":"1994","journal-title":"Artif Organs"},{"key":"R2-19-20210129","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1378\/chest.107.6.1689","article-title":"Intravenacaval membrane oxygenation and carbon dioxide removal in severe acute respiratory failure.","volume":"107","author":"Conrad","year":"1995","journal-title":"Chest"},{"key":"R3-19-20210129","first-page":"147","article-title":"Intravenous oxygenation and CO2 removal device: IVOX.","volume":"37","author":"Durbin","year":"1992","journal-title":"Respir Care"},{"key":"R4-19-20210129","first-page":"120","article-title":"Intravascular oxygenation for advanced respiratory failure.","volume":"38","author":"Jurmann","year":"1992","journal-title":"ASAIO J"},{"key":"R5-19-20210129","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1111\/j.1525-1594.1992.tb00271.x","article-title":"Intravascular oxygenator: a new alternative method for augmenting blood gas transfer in patients with acute respiratory failure.","volume":"16","author":"Mortensen","year":"1992","journal-title":"Artif Organs"},{"key":"R6-19-20210129","first-page":"822","article-title":"Work of breathing in patients with chronic obstructive pulmonary disease in acute respiratory failure.","volume":"131","author":"Fleury","year":"1985","journal-title":"Am Rev Respir Dis"},{"key":"R7-19-20210129","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1146\/annurev.med.52.1.221","article-title":"Acute respiratory distress syndrome: physiology and new management strategies.","volume":"52","author":"Weinacker","year":"2001","journal-title":"Ann Rev Med"},{"key":"R8-19-20210129","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/BF02425148","article-title":"Reduction of ventilator settings allowed by intravenous oxygenator (IVOX) in ARDS patients.","volume":"21","author":"Mira","year":"1995","journal-title":"Intensive Care Med"},{"key":"R9-19-20210129","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1097\/00002480-199901000-00010","article-title":"Intravascular membrane oxygenator and carbon dioxide removal devices: a review of performance and improvements.","volume":"45","author":"Zwischenberger","year":"1999","journal-title":"ASAIO J"},{"key":"R10-19-20210129","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1097\/00000542-199211000-00004","article-title":"Clinical trials of an intravenous oxygenator in patients with adult respiratory distress syndrome.","volume":"77","author":"High","year":"1992","journal-title":"Anesthesiology"},{"key":"R11-19-20210129","doi-asserted-by":"crossref","first-page":"4142","DOI":"10.1021\/ie9706875","article-title":"Gas-liquid desorption through blind-ended microporous hollow fibers for an intravascular artificial lung.","volume":"37","author":"Baskaran","year":"1998","journal-title":"Ind Eng Chem Res"},{"key":"R12-19-20210129","doi-asserted-by":"crossref","first-page":"M735","DOI":"10.1097\/00002480-199407000-00096","article-title":"Effects of blood phase oscillation on gas transfer in a microporous intravascular lung.","volume":"40","author":"High","year":"1994","journal-title":"ASAIO J"},{"key":"R13-19-20210129","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1114\/1.115","article-title":"Enhancement of O2 and CO2 transfer through microporous hollow fibers by pressure cycling.","volume":"26","author":"Nodelman","year":"1998","journal-title":"Ann Biomed Eng"},{"key":"R14-19-20210129","doi-asserted-by":"crossref","first-page":"M533","DOI":"10.1097\/00002480-199407000-00057","article-title":"Small intrapulmonary artery lung prototypes: design, construction, and in vitro water testing.","volume":"40","author":"Snider","year":"1994","journal-title":"ASAIO J"},{"key":"R15-19-20210129","doi-asserted-by":"crossref","first-page":"M435","DOI":"10.1097\/00002480-199609000-00026","article-title":"Recent progress in engineering the Pittsburgh intravenous membrane oxygenator.","volume":"42","author":"Federspiel","year":"1996","journal-title":"ASAIO J"},{"key":"R16-19-20210129","doi-asserted-by":"crossref","first-page":"M609","DOI":"10.1097\/00002480-199609000-00060","article-title":"Acute in vivo studies of the Pittsburgh intravenous membrane oxygenator.","volume":"42","author":"Macha","year":"1996","journal-title":"ASAIO J"},{"key":"R17-19-20210129","doi-asserted-by":"crossref","first-page":"M725","DOI":"10.1097\/00002480-199703000-00047","article-title":"Development of a low flow resistance intravenous oxygenator.","volume":"43","author":"Federspiel","year":"1997","journal-title":"ASAIO J"},{"key":"R18-19-20210129","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1177\/026765919901400411","article-title":"Progress with the development of the intravenous membrane oxygenator.","volume":"14","author":"Hattler","year":"1999","journal-title":"Perfusion"},{"key":"R19-19-20210129","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1097\/00002480-200005000-00004","article-title":"Ex vivo testing of the intravenous membrane oxygenator.","volume":"46","author":"Federspiel","year":"2000","journal-title":"ASAIO J"},{"key":"R20-19-20210129","first-page":"133","article-title":"The Artificial Lung,","author":"Hattler","year":"2002"},{"key":"R21-19-20210129","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1067\/mtc.2002.123811","article-title":"A respiratory gas exchange catheter: in vitro and in vivo tests in large animals.","volume":"124","author":"Hattler","year":"2002","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R22-19-20210129","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1097\/00002480-200109000-00003","article-title":"Acute in vivo testing of an intravascular respiratory support catheter.","volume":"47","author":"Golob","year":"2001","journal-title":"ASAIO J"},{"key":"R23-19-20210129","first-page":"370","article-title":"Acute in vivo testing of a respiratory assist catheter: implants in calves versus sheep.","volume":"49","author":"Eash","year":"2003","journal-title":"ASAIO J"},{"key":"R24-19-20210129","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1191\/0267659104pf748oa","article-title":"Compact intra- and extracorporeal oxygenator developments.","volume":"19","author":"Cattaneo","year":"2004","journal-title":"Perfusion"},{"key":"R25-19-20210129","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1177\/039139880502800309","article-title":"New fiber configuration for intravenous gas exchange.","volume":"28","author":"Cattaneo","year":"2005","journal-title":"Int J Artif Organs"},{"key":"R26-19-20210129","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1097\/01.mat.0000204151.56591.28","article-title":"Intravascular blood oxygenation using hollow fibers in a disk-shaped configuration: experimental evaluation of the relationship between porosity and performance.","volume":"52","author":"Cattaneo","year":"2006","journal-title":"ASAIO J"},{"key":"R27-19-20210129","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1097\/01.mat.0000199752.89066.83","article-title":"Investigating the effects of random balloon pulsation on gas exchange in a respiratory assist catheter.","volume":"52","author":"Eash","year":"2006","journal-title":"ASAIO J"},{"key":"R28-19-20210129","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1097\/01.MAT.0000153648.11692.D0","article-title":"Evaluation of local gas exchange in a pulsating respiratory support catheter.","volume":"51","author":"Eash","year":"2005","journal-title":"ASAIO J"},{"key":"R29-19-20210129","doi-asserted-by":"crossref","first-page":"M466","DOI":"10.1097\/00002480-199307000-00063","article-title":"A pumping intravascular artificial lung with active mixing.","volume":"39","author":"Makarewicz","year":"1993","journal-title":"ASAIO J"},{"key":"R30-19-20210129","doi-asserted-by":"crossref","first-page":"M747","DOI":"10.1097\/00002480-199407000-00099","article-title":"A dynamic intravascular artificial lung.","volume":"40","author":"Makarewicz","year":"1994","journal-title":"ASAIO J"},{"key":"R31-19-20210129","first-page":"383","article-title":"Intravascular Lung Assist Device and Method.","volume":"037","author":"Vaslef","year":"1991","journal-title":"US Patent 5"},{"key":"R32-19-20210129","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1097\/00002216-198907000-00160","article-title":"Development of an intravascular lung assist device.","volume":"35","author":"Vaslef","year":"1989","journal-title":"ASAIO Trans"},{"key":"R33-19-20210129","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/j.jtcvs.2005.04.032","article-title":"Progress toward an ambulatory pump-lung.","volume":"130","author":"Wu","year":"2005","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R34-19-20210129","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1097\/01.mat.0000178970.00971.43","article-title":"Evaluation of a pumping assist lung that uses a rotating fiber bundle.","volume":"51","author":"Svitek","year":"2005","journal-title":"ASAIO J"},{"key":"R36-19-20210129","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1097\/01.MAT.0000138078.04558.FE","article-title":"Evaluation of plasma resistant hollow fiber membranes for artificial lungs.","volume":"50","author":"Eash","year":"2004","journal-title":"ASAIO J"},{"key":"R37-19-20210129","first-page":"633","article-title":"AAMI standards and recommended practices: Biomedical equipment, Part 1: General safety and design; Equipment for therapy and surgery,","year":"1996"},{"key":"R38-19-20210129","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1097\/00002480-200211000-00009","article-title":"A comparative in vitro hemolysis study of a pulsating intravenous artificial lung.","volume":"48","author":"Lund","year":"2002","journal-title":"ASAIO J"},{"key":"R39-19-20210129","first-page":"56","article-title":"Effect of vessel compliance on the in-vitro performance of a pulsating respiratory support catheter.","volume":"124","author":"Garcia","year":"2002","journal-title":""},{"key":"R40-19-20210129","first-page":"910","article-title":"Encyclopedia of Biomaterials and Biomedical Engineering,","author":"Federspiel","year":"2004"},{"key":"R41-19-20210129","doi-asserted-by":"crossref","first-page":"2885","DOI":"10.1002\/aic.10553","article-title":"Effect of Taylor vortices on mass transfer from a rotating cylinder.","volume":"51","author":"Srinivasan","year":"2005","journal-title":"AIChE J"},{"key":"R42-19-20210129","doi-asserted-by":"crossref","first-page":"5457","DOI":"10.1103\/PhysRevE.59.5457","article-title":"Velocity structure functions, scaling, and transitions in high-Reynolds-number Couette-Taylor flow.","volume":"59","author":"Lewis","year":"1999","journal-title":"Phys Rev E"},{"key":"R43-19-20210129","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1103\/PhysRevLett.68.1515","article-title":"Turbulent flow between concentric rotating cylinders at large Reynolds number.","volume":"68","author":"Lathrop","year":"1992","journal-title":"Phys Rev Lett"},{"key":"R44-19-20210129","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/S0009-2509(98)00234-6","article-title":"Prediction of mass transfer rates in spatially periodic flows.","volume":"54","author":"Baier","year":"1998","journal-title":"Chem Eng Sci"}],"container-title":["ASAIO Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MAT.0b013e318031af3b","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T16:41:22Z","timestamp":1786034482000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00002480-200705000-00019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,5]]},"references-count":43,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2007]]}},"URL":"https:\/\/doi.org\/10.1097\/mat.0b013e318031af3b","relation":{},"ISSN":["1058-2916"],"issn-type":[{"value":"1058-2916","type":"print"}],"subject":[],"published":{"date-parts":[[2007,5]]}}}