{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T22:08:52Z","timestamp":1778623732813,"version":"3.51.4"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Although drug-eluting stents (DES) are effective, stent thrombosis (ST) remains a major concern in patients with acute myocardial infarction (AMI) who undergo DES implantation. We aimed to evaluate the incidence of late stent malapposition (SM) and uncovered struts 12 months after implantation of a bioabsorbable polymer everolimus-eluting stent (BP-EES) or a durable polymer zotarolimus-eluting stent (DP-ZES) in patients with AMI using optical coherence tomography (OCT).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Sixty-nine patients with AMI were randomly assigned 2:1 to the BP-EES (46 patients) or DP-ZES (23 patients) groups. The coprimary endpoints were the incidences of late SM and uncovered stent struts in OCT strut-level analysis at 12 months postimplantation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The 51 patients who completed the 12-month follow-up OCT (BP-EES, 36 patients, 39 lesions; DP-ZES, 15 patients, 18 lesions) showed no intergroup differences in the incidence of acute SM (BP-EES vs. DP-ZES; 12.25\u2005\u00b1\u200514.27% vs. 12.35\u2005\u00b1\u200510.55%, <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u20050.981) at the index procedure. The incidence of late SM (0.12\u2005\u00b1\u20050.42% vs. 0.14\u2005\u00b1\u20050.25%, <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u20050.873) and uncovered struts (1.69\u2005\u00b1\u20053.44% vs. 2.45\u2005\u00b1\u20053.23%, <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u20050.532) also did not differ between the two DES groups at 12-month postimplantation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Twelve-month OCT measurements showed no significant differences in late SM and uncovered struts between the BP-EES and DP-ZES stents. Thus, contemporary second-generation DES show a very low rate of late SM and uncovered struts after 12 months in AMI, regardless of stent polymer type.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Trial registration<\/jats:title>\n            <jats:p>Late stent strut apposition and coverage after drug-eluting stent implantation by OCT in patients with AMI (APPOSITION AMI-II) (NCT02770651).<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mca.0000000000001536","type":"journal-article","created":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T06:00:09Z","timestamp":1748325609000},"page":"610-617","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Late stent strut apposition and coverage after drug-eluting stent implantation by optical coherence tomography in patients with acute myocardial infarction"],"prefix":"10.1097","volume":"36","author":[{"given":"Cheol Hyun","family":"Lee","sequence":"first","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seonhwa","family":"Lee","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jongmin","family":"Hwang","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"In-Cheol","family":"Kim","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yun-Kyeong","family":"Cho","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyuck-Jun","family":"Yoon","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyungseop","family":"Kim","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chang-Wook","family":"Nam","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seung-Ho","family":"Hur","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,9,24]]},"reference":[{"key":"R1-20250925","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1161\/CIRCULATIONAHA.113.001790","article-title":"Pathology of second-generation everolimus-eluting stents versus first-generation sirolimus- and paclitaxel-eluting stents in humans.","volume":"129","author":"Otsuka","year":"2014","journal-title":"Circulation"},{"key":"R2-20250925","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1161\/CIRCULATIONAHA.107.762047","article-title":"Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients: an autopsy study.","volume":"118","author":"Nakazawa","year":"2008","journal-title":"Circulation"},{"key":"R3-20250925","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.ijcard.2014.02.036","article-title":"Differential healing response attributed to culprit lesions of patients with acute coronary syndromes and stable coronary artery after implantation of drug-eluting stents: an optical coherence tomography study.","volume":"173","author":"R\u00e4ber","year":"2014","journal-title":"Int J Cardiol"},{"key":"R4-20250925","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.jcin.2009.01.012","article-title":"Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable\/unstable angina: insights from optical coherence tomography.","volume":"2","author":"Gonzalo","year":"2009","journal-title":"JACC Cardiovasc Interv"},{"key":"R5-20250925","doi-asserted-by":"crossref","first-page":"1643","DOI":"10.1056\/NEJMoa2108749","article-title":"Dual antiplatelet therapy after PCI in patients at high bleeding risk.","volume":"385","author":"Valgimigli","year":"2021","journal-title":"N Engl J Med"},{"key":"R6-20250925","doi-asserted-by":"crossref","first-page":"1870","DOI":"10.1016\/j.jcin.2021.07.016","article-title":"3- or 1-Month DAPT in Patients at High Bleeding Risk Undergoing Everolimus-Eluting Stent Implantation.","volume":"14","author":"Mehran","year":"2021","journal-title":"JACC Cardiovasc Interv"},{"key":"R7-20250925","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1007\/s00508-018-1333-0","article-title":"What is new in the 2017 ESC clinical practice guidelines: management of acute myocardial infarction in patients presenting with ST-segment elevation.","volume":"130","author":"Lang","year":"2018","journal-title":"Wien Klin Wochenschr"},{"key":"R8-20250925","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.amjcard.2006.11.068","article-title":"Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation.","volume":"99","author":"Takano","year":"2007","journal-title":"Am J Cardiol"},{"key":"R9-20250925","doi-asserted-by":"crossref","first-page":"2352","DOI":"10.1161\/CIRCULATIONAHA.107.688416","article-title":"Thrombosis in coronary drug-eluting stents: report from the meeting of the Circulatory System Medical Devices Advisory Panel of the Food and Drug Administration Center for Devices and Radiologic Health, December 7-8, 2006.","volume":"115","author":"Laskey","year":"2007","journal-title":"Circulation"},{"key":"R10-20250925","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.amjcard.2012.08.037","article-title":"Comparison of early strut coverage between zotarolimus- and everolimus-eluting stents using optical coherence tomography.","volume":"111","author":"Kim","year":"2013","journal-title":"Am J Cardiol"},{"key":"R11-20250925","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1253\/circj.CJ-14-1000","article-title":"Early neointimal coverage and vasodilator response following biodegradable polymer sirolimus-eluting vs. durable polymer zotarolimus-eluting stents in patients with acute coronary syndrome \u2013HATTRICK-OCT trial.","volume":"79","author":"Karjalainen","year":"2015","journal-title":"Circ J"},{"key":"R12-20250925","doi-asserted-by":"crossref","first-page":"1304","DOI":"10.1093\/eurheartj\/ehm114","article-title":"Late incomplete apposition after drug-eluting stent implantation: incidence and potential for adverse clinical outcomes.","volume":"28","author":"Siqueira","year":"2007","journal-title":"Eur Heart J"},{"key":"R13-20250925","doi-asserted-by":"crossref","first-page":"2426","DOI":"10.1161\/CIRCULATIONAHA.106.658237","article-title":"Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation.","volume":"115","author":"Cook","year":"2007","journal-title":"Circulation"},{"key":"R14-20250925","doi-asserted-by":"crossref","first-page":"880","DOI":"10.4070\/kcj.2020.0198","article-title":"Long-term clinical outcomes of drug-eluting stent malapposition.","volume":"50","author":"Lee","year":"2020","journal-title":"Korean Circulation J"},{"key":"R15-20250925","doi-asserted-by":"crossref","first-page":"e979","DOI":"10.4244\/EIJY15M09_12","article-title":"Late-acquired incomplete stent apposition after everolimus-eluting stent versus sirolimus-eluting stent implantation in patients with non-ST-segment elevation myocardial infarction and ST-segment elevation myocardial infarction.","volume":"12","author":"Hur","year":"2016","journal-title":"EuroIntervention"},{"key":"R16-20250925","doi-asserted-by":"crossref","first-page":"e002372","DOI":"10.1161\/CIRCINTERVENTIONS.114.002372","article-title":"Efficacy and safety of a novel bioabsorbable polymer-coated, everolimus-eluting coronary stent: the EVOLVE II Randomized Trial.","volume":"8","author":"Kereiakes","year":"2015","journal-title":"Circ Cardiovasc Interv"},{"key":"R17-20250925","doi-asserted-by":"crossref","first-page":"e006034","DOI":"10.1161\/CIRCINTERVENTIONS.117.006034","article-title":"The OCT-ORION study: a randomized optical coherence tomography study comparing resolute integrity to biomatrix drug-eluting stent on the degree of early stent healing and late lumen loss.","volume":"11","author":"Lee","year":"2018","journal-title":"Circ Cardiovasc Interv"},{"key":"R18-20250925","doi-asserted-by":"crossref","first-page":"2047","DOI":"10.4244\/EIJ-D-17-00529","article-title":"Final five-year clinical outcomes in the EVOLVE trial: a randomised evaluation of a novel bioabsorbable polymer-coated, everolimus-eluting stent.","volume":"13","author":"Meredith","year":"2018","journal-title":"EuroIntervention"},{"key":"R19-20250925","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.jcin.2012.11.006","article-title":"Clinical outcome of patients with and without diabetes mellitus after percutaneous coronary intervention with the resolute zotarolimus-eluting stent: 2-year results from the prospectively pooled analysis of the international global RESOLUTE program.","volume":"6","author":"Silber","year":"2013","journal-title":"JACC Cardiovasc Interv"},{"key":"R20-20250925","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1016\/j.jcin.2016.05.043","article-title":"Prevalence and clinical impact of tissue protrusion after stent implantation: an ADAPT-DES intravascular ultrasound substudy.","volume":"9","author":"Qiu","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"R21-20250925","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1016\/j.jacc.2005.05.068","article-title":"Late incomplete stent apposition after sirolimus-eluting stent implantation: a serial intravascular ultrasound analysis.","volume":"46","author":"Ako","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"R22-20250925","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1136\/hrt.2007.120154","article-title":"Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials.","volume":"94","author":"Hoffmann","year":"2008","journal-title":"Heart (British Cardiac Society)"},{"key":"R23-20250925","doi-asserted-by":"crossref","first-page":"2379","DOI":"10.1161\/CIRCULATIONAHA.107.697136","article-title":"What to do about late incomplete stent apposition?","volume":"115","author":"Mintz","year":"2007","journal-title":"Circulation"},{"key":"R24-20250925","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1186\/s13063-019-3293-8","article-title":"Re-endothelialisation after Synergy stent and Absorb bioresorbable vascular scaffold implantation in acute myocardial infarction: COVER-AMI study.","volume":"20","author":"Lhermusier","year":"2019","journal-title":"Trials"},{"key":"R25-20250925","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.jacc.2008.04.030","article-title":"Endothelial cell recovery between comparator polymer-based drug-eluting stents.","volume":"52","author":"Joner","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"R26-20250925","doi-asserted-by":"crossref","first-page":"e004801","DOI":"10.1161\/CIRCINTERVENTIONS.116.004801","article-title":"Serial assessment of strut coverage of biodegradable polymer drug-eluting stent at 1, 2, and 3 months after stent implantation by optical frequency domain imaging: the DISCOVERY 1TO3 Study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months).","volume":"10","author":"Chevalier","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"key":"R27-20250925","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1093\/eurheartj\/ehp480","article-title":"An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study.","volume":"31","author":"Barlis","year":"2010","journal-title":"Eur Heart J"},{"key":"R28-20250925","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1056\/NEJMoa1910021","article-title":"Polymer-based or polymer-free stents in patients at high bleeding risk.","volume":"382","author":"Windecker","year":"2020","journal-title":"N Engl J Med"}],"container-title":["Coronary Artery Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MCA.0000000000001536","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T16:01:02Z","timestamp":1758816062000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MCA.0000000000001536"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,24]]},"references-count":28,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/mca.0000000000001536","relation":{},"ISSN":["0954-6928","1473-5830"],"issn-type":[{"value":"0954-6928","type":"print"},{"value":"1473-5830","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,24]]}}}