{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T08:57:48Z","timestamp":1785488268221,"version":"3.56.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To assess whether non\u2013ECG-gated computed tomography (CT) reliably quantifies aortic valve calcification (AVC) for diagnosing severe aortic stenosis and to compare the agreement and diagnostic performance of Agatston versus volume scoring.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this retrospective single-centre study, 129 consecutive patients with echocardiographically confirmed severe aortic stenosis (mean age, 83.1\u2005\u00b1\u20056.3 years; 46 men, 83 women) underwent same-session ECG-gated (3\u2009mm) and Non\u2013ECG-gated (5\u2009mm) non-contrast CT between 21 March 2020 and 16 April 2025. AVC was quantified using Agatston and volume methods. Agreement between non-gated and gated scores was assessed by Pearson correlation, Bland\u2013Altman analysis, and Deming regression. Diagnostic performance for sex-specific Agatston thresholds (\u22652000 units men, \u22651300 units women) was evaluated using receiver operating characteristic (ROC) analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Volume scores on non\u2013ECG-gated CT correlated more strongly with ECG-gated CT scores than Agatston scores (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      \u2005=\u20050.95 vs. 0.69,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u20050.001). Bland\u2013Altman analysis demonstrated substantial negative bias and proportional error for Agatston scores (mean difference, \u2212921.1 units; limits of agreement, \u22122900.8 to +1058.6), while volume scores showed minimal bias and no proportional error (+16.5\u2009mm\n                      <jats:sup>3<\/jats:sup>\n                      ; \u2212648.5 to +681.4). Deming regression confirmed closer agreement for volume scores (slope, 1.02;\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      \u2005=\u20050.90). ROC analysis showed higher area under the curve values for volume scores (0.976 for men, 0.975 for women) than for Agatston scores (0.946 and 0.967, respectively).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Non\u2013ECG-gated CT enables reliable quantification of aortic valve calcium in severe aortic stenosis. Volume scoring demonstrates superior agreement and diagnostic performance compared with Agatston scoring, supporting its use as a robust, density-independent metric for opportunistic assessment of AVC on routine chest CT.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/mca.0000000000001623","type":"journal-article","created":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T14:00:10Z","timestamp":1771423210000},"page":"409-417","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Diagnostic agreement of volume and Agatston scoring for aortic valve calcification on non\u2013ECG-gated computed tomography in severe aortic stenosis"],"prefix":"10.1097","volume":"37","author":[{"given":"Kotaro","family":"Ouchi","sequence":"first","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toru","family":"Sakuma","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shu","family":"Okubo","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ayumi","family":"Nojiri","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, Jikei University School of Medicine, Minato, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroya","family":"Ojiri","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,2,18]]},"reference":[{"key":"R1-20260731","doi-asserted-by":"crossref","first-page":"1835","DOI":"10.1016\/j.jcmg.2019.01.045","article-title":"Why and how to measure aortic valve calcification in patients with aortic stenosis.","volume":"12","author":"Pawade","year":"2019","journal-title":"JACC Cardiovasc Imaging"},{"key":"R2-20260731","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1111\/j.1742-1241.2012.02916.x","article-title":"Aortic valve calcification \u2013 a commonly observed but frequently ignored finding during CT scanning of the chest.","volume":"66","author":"Raju","year":"2012","journal-title":"Int J Clin Pract"},{"key":"R3-20260731","doi-asserted-by":"crossref","first-page":"20200894","DOI":"10.1259\/bjr.20200894","article-title":"Reporting incidental coronary, aortic valve and cardiac calcification on non-gated thoracic computed tomography: a consensus statement from the BSCI\/BSCCT and BSTI.","volume":"94","author":"Williams","year":"2021","journal-title":"Br J Radiol"},{"key":"R4-20260731","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1007\/s00330-022-09114-6","article-title":"Optimal threshold score of aortic valve calcification for identification of significant aortic stenosis on non-electrocardiographic-gated computed tomography.","volume":"33","author":"Ouchi","year":"2023","journal-title":"Eur Radiol"},{"key":"R5-20260731","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1016\/j.jcct.2024.03.014","article-title":"Accuracy of aortic valve calcification volume score for identification of significant aortic stenosis on non-electrocardiographic-gated computed tomography compared to the Agatston scoring system.","volume":"18","author":"Ouchi","year":"2024","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R6-20260731","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/0735-1097(90)90282-T","article-title":"Quantification of coronary artery calcium using ultrafast computed tomography.","volume":"15","author":"Agatston","year":"1990","journal-title":"J Am Coll Cardiol"},{"key":"R7-20260731","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.jcmg.2019.08.007","article-title":"Reliability of CAC scoring on nongated compared with gated cardiac CT scans from MESA.","volume":"13","author":"Almeida","year":"2020","journal-title":"JACC Cardiovasc Imaging"},{"key":"R8-20260731","doi-asserted-by":"crossref","first-page":"W1","DOI":"10.2214\/AJR.05.0052","article-title":"Variability of repeated coronary artery calcium measurements on low-dose ECG-gated 16-MDCT.","volume":"187","author":"Horiguchi","year":"2006","journal-title":"AJR Am J Roentgenol"},{"key":"R9-20260731","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1148\/radiology.208.3.9722864","article-title":"Coronary artery disease: improved reproducibility of calcium scoring with an electron-beam CT volumetric method.","volume":"208","author":"Callister","year":"1998","journal-title":"Radiology"},{"key":"R10-20260731","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1093\/ehjci\/jew335","article-title":"Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European Association of Cardiovascular Imaging and the American Society of Echocardiography.","volume":"18","author":"Baumgartner","year":"2017","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"R11-20260731","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1093\/eurheartj\/ehab395","article-title":"2021 ESC\/EACTS guidelines for the management of valvular heart disease.","volume":"43","author":"Vahanian","year":"2022","journal-title":"Eur Heart J"},{"key":"R12-20260731","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.echo.2014.10.003","article-title":"Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging.","volume":"28","author":"Lang","year":"2015","journal-title":"J Am Soc Echocardiogr"},{"key":"R13-20260731","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1016\/j.jacc.2022.05.036","article-title":"Prevalence and prognostic implications of discordant grading and flow-gradient patterns in moderate aortic stenosis.","volume":"80","author":"Stassen","year":"2022","journal-title":"J Am Coll Cardiol"},{"key":"R14-20260731","doi-asserted-by":"crossref","first-page":"2645","DOI":"10.1093\/eurheartj\/ehw096","article-title":"Low-gradient aortic stenosis.","volume":"37","author":"Clavel","year":"2016","journal-title":"Eur Heart J"},{"key":"R15-20260731","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.jcmg.2017.01.002","article-title":"Cardiac imaging for assessing low-gradient severe aortic stenosis.","volume":"10","author":"Clavel","year":"2017","journal-title":"JACC Cardiovasc Imaging"},{"key":"R16-20260731","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.echo.2017.01.007","article-title":"Recommendations for noninvasive evaluation of native valvular regurgitation: a report from the American Society of Echocardiography developed in collaboration with the Society for Cardiovascular Magnetic Resonance.","volume":"30","author":"Zoghbi","year":"2017","journal-title":"J Am Soc Echocardiogr"},{"key":"R17-20260731","first-page":"1","article-title":"Design based on intra-class correlation coefficients.","volume":"1","author":"Lew","year":"2010","journal-title":"Am J Biostat"},{"key":"R18-20260731","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1213\/ANE.0000000000002864","article-title":"Correlation coefficients: appropriate use and interpretation.","volume":"126","author":"Schober","year":"2018","journal-title":"Anesth Analg"},{"key":"R19-20260731","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research.","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"R20-20260731","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.jcct.2010.01.013","article-title":"Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque.","volume":"4","author":"Achenbach","year":"2010","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R21-20260731","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.atherosclerosis.2014.12.040","article-title":"Scoring of coronary artery calcium scans: history, assumptions, current limitations, and future directions.","volume":"239","author":"Alluri","year":"2015","journal-title":"Atherosclerosis"},{"key":"R22-20260731","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1148\/rg.210122","article-title":"Coronary artery calcium scoring: current status and future directions.","volume":"42","author":"Gupta","year":"2022","journal-title":"Radiographics"},{"key":"R23-20260731","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.jcmg.2017.04.018","article-title":"Coronary artery calcium volume and density: potential interactions and overall predictive value: the Multi-Ethnic Study of Atherosclerosis.","volume":"10","author":"Criqui","year":"2017","journal-title":"JACC Cardiovasc Imaging"},{"key":"R24-20260731","doi-asserted-by":"crossref","first-page":"e018437","DOI":"10.1161\/CIRCIMAGING.125.018437","article-title":"Aortic stenosis grading with CT: do we still need noncontrast scans?","volume":"18","author":"Eberhard","year":"2025","journal-title":"Circ Cardiovasc Imaging"},{"key":"R25-20260731","doi-asserted-by":"crossref","first-page":"8472","DOI":"10.1038\/s41598-025-93744-5","article-title":"Deep learning\u2013based automatic quantification of aortic valve calcification on contrast-enhanced coronary CT angiography.","volume":"15","author":"Park","year":"2025","journal-title":"Sci Rep"},{"key":"R26-20260731","doi-asserted-by":"crossref","first-page":"2329","DOI":"10.1016\/j.jacc.2013.08.1621","article-title":"The complex nature of discordant severe calcified aortic valve disease grading: new insights from combined Doppler echocardiographic and computed tomographic study.","volume":"62","author":"Clavel","year":"2013","journal-title":"J Am Coll Cardiol"}],"container-title":["Coronary Artery Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MCA.0000000000001623","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T08:01:18Z","timestamp":1785484878000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MCA.0000000000001623"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,18]]},"references-count":26,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/mca.0000000000001623","relation":{},"ISSN":["0954-6928","1473-5830"],"issn-type":[{"value":"0954-6928","type":"print"},{"value":"1473-5830","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,18]]},"assertion":[{"value":"2025-11-30","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-01-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}