{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T18:26:15Z","timestamp":1787768775858,"version":"build-2784847793"},"reference-count":60,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>We will briefly review the classification of shock and the hallmark features of each subtype. Available modalities for monitoring shock patients will be discussed, along with evidence supporting the use, common pitfalls, and practical considerations of each method.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>As older, invasive monitoring methods such as the pulmonary artery catheter have fallen out of favor, newer technologies for cardiac output estimation, echocardiography, and noninvasive tests such as passive leg raising have gained popularity. Newer forms of minimally invasive or noninvasive monitoring (such as pulse contour analysis and chest bioreactance) show promise but will need further investigation before they are considered validated for practical use. There remains no \u2018ideal\u2019 test or standard of care for cardiopulmonary monitoring of shock patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>Shock has potentially reversible causes of morbidity and mortality if appropriately diagnosed and managed. Older methods of invasive monitoring have significant limitations but are still critical for managing shock in certain patients and settings. Newer methods are easier to employ, but further validation is needed. Multiple modalities along with careful clinical assessment are often useful in distinguishing shock subtypes. Best practice standards for monitoring should be based on institutional expertise.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mcc.0000000000000407","type":"journal-article","created":{"date-parts":[[2017,4,8]],"date-time":"2017-04-08T17:22:32Z","timestamp":1491672152000},"page":"223-231","source":"Crossref","is-referenced-by-count":13,"title":["Cardiopulmonary monitoring of shock"],"prefix":"10.1097","volume":"23","author":[{"given":"James","family":"Simmons","sequence":"first","affiliation":[{"name":"Division of Pulmonary, Critical Care, and Sleep, Department of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Corey E.","family":"Ventetuolo","sequence":"additional","affiliation":[{"name":"Division of Pulmonary, Critical Care, and Sleep, Department of Medicine"},{"name":"Department of Health Services, Policy, and Practice, Brown University, Providence, Rhode Island, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230913","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1097\/01.shk.0000186931.02852.5f","article-title":"Diagnostic accuracy of left ventricular function for identifying sepsis among emergency department patients with nontraumatic symptomatic undifferentiated hypotension","volume":"24","author":"Jones","year":"2005","journal-title":"Shock"},{"key":"R2-20230913","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1056\/NEJMoa0907118","article-title":"Comparison of dopamine and norepinephrine in the treatment of shock","volume":"362","author":"De Backer","year":"2010","journal-title":"N Engl J Med"},{"key":"R3-20230913","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1001\/jama.2016.0287","article-title":"The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3)","volume":"315","author":"Singer","year":"2016","journal-title":"JAMA"},{"key":"R4-20230913","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1097\/CCM.0b013e31827c09f8","article-title":"Benchmarking the incidence and mortality of severe sepsis in the United States","volume":"41","author":"Gaieski","year":"2013","journal-title":"Crit Care Med"},{"key":"R5-20230913","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1056\/NEJMoa1401602","article-title":"A randomized trial of protocol-based care for early septic shock","volume":"370","author":"Yealy","year":"2014","journal-title":"N Engl J Med"},{"key":"R6-20230913","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1161\/01.CIR.91.3.873","article-title":"Current spectrum of cardiogenic shock and effect of early revascularization on mortality. Results of an International Registry. SHOCK Registry Investigators","volume":"91","author":"Hochman","year":"1995","journal-title":"Circulation"},{"key":"R7-20230913","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1056\/NEJMoa1404380","article-title":"Goal-directed resuscitation for patients with early septic shock","volume":"371","author":"Peake","year":"2014","journal-title":"N Engl J Med"},{"key":"R8-20230913","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1056\/NEJM199902113400601","article-title":"A multicenter, randomized, controlled clinical trial of transfusion requirements in critical care. Transfusion Requirements in Critical Care Investigators, Canadian Critical Care Trials Group","volume":"340","author":"Hebert","year":"1999","journal-title":"N Engl J Med"},{"key":"R9-20230913","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1186\/cc2851","article-title":"Clinical review: hemorrhagic shock","volume":"8","author":"Gutierrez","year":"2004","journal-title":"Crit Care"},{"key":"R10-20230913","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1007\/s002689900340","article-title":"Use of pentastarch solution in the treatment of patients with hemorrhagic hypovolemia: randomized phase II study in the emergency room","volume":"22","author":"Younes","year":"1998","journal-title":"World J Surg"},{"key":"R11-20230913","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1183\/13993003.00024-2016","article-title":"Acute pulmonary embolism: mortality prediction by the 2014 European Society of Cardiology risk stratification model","volume":"48","author":"Becattini","year":"2016","journal-title":"Eur Respir J"},{"key":"R12-20230913","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.amjcard.2013.11.071","article-title":"Predictors of moderate-to-severe pericardial effusion, cardiac tamponade, and electromechanical dissociation in patients with ST-elevation myocardial infarction","volume":"113","author":"Figueras","year":"2014","journal-title":"Am J Cardiol"},{"key":"R13-20230913","doi-asserted-by":"crossref","first-page":"2729","DOI":"10.1097\/00003246-200008000-00007","article-title":"Effects of perfusion pressure on tissue perfusion in septic shock","volume":"28","author":"LeDoux","year":"2000","journal-title":"Crit Care Med"},{"key":"R14-20230913","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1097\/TA.0000000000000600","article-title":"A controlled resuscitation strategy is feasible and safe in hypotensive trauma patients: results of a prospective randomized pilot trial","volume":"78","author":"Schreiber","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"key":"R15-20230913","doi-asserted-by":"crossref","first-page":"1583","DOI":"10.1056\/NEJMoa1312173","article-title":"High versus low blood-pressure target in patients with septic shock","volume":"370","author":"Asfar","year":"2014","journal-title":"N Engl J Med"},{"key":"R16-20230913","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.annemergmed.2009.08.014","article-title":"Multicenter study of central venous oxygen saturation (ScvO(2)) as a predictor of mortality in patients with sepsis","volume":"55","author":"Pope","year":"2010","journal-title":"Ann Emerg Med"},{"key":"R17-20230913","doi-asserted-by":"crossref","first-page":"R80","DOI":"10.1186\/cc13842","article-title":"Ventriculoarterial decoupling in human septic shock","volume":"18","author":"Guarracino","year":"2014","journal-title":"Crit Care"},{"key":"R18-20230913","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1097\/00000542-200508000-00007","article-title":"Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions","volume":"103","author":"Dueck","year":"2005","journal-title":"Anesthesiology"},{"key":"R19-20230913","doi-asserted-by":"crossref","first-page":"1891","DOI":"10.1378\/chest.126.6.1891","article-title":"Lack of equivalence between central and mixed venous oxygen saturation","volume":"126","author":"Chawla","year":"2004","journal-title":"Chest"},{"key":"R20-20230913","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1097\/00003246-199808000-00020","article-title":"Importance of the sampling site for measurement of mixed venous oxygen saturation in shock","volume":"26","author":"Edwards","year":"1998","journal-title":"Crit Care Med"},{"key":"R21-20230913","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/BF01705041","article-title":"Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients","volume":"18","author":"Martin","year":"1992","journal-title":"Intensive Care Med"},{"key":"R22-20230913","doi-asserted-by":"crossref","first-page":"1572","DOI":"10.1007\/s00134-004-2337-y","article-title":"Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill","volume":"30","author":"Reinhart","year":"2004","journal-title":"Intensive Care Med"},{"key":"R23-20230913","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1056\/NEJM199510193331601","article-title":"A trial of goal-oriented hemodynamic therapy in critically ill patients. SvO2 Collaborative Group","volume":"333","author":"Gattinoni","year":"1995","journal-title":"N Engl J Med"},{"key":"R24-20230913","first-page":"513480","article-title":"Can transthoracic echocardiography be used to predict fluid responsiveness in the critically ill patient? A systematic review","volume":"2012","author":"Mandeville","year":"2012","journal-title":"Crit Care Res Pract"},{"key":"R25-20230913","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1378\/chest.07-2331","article-title":"Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares","volume":"134","author":"Marik","year":"2008","journal-title":"Chest"},{"key":"R26-20230913","doi-asserted-by":"crossref","first-page":"1354","DOI":"10.1378\/chest.116.5.1354","article-title":"Persistent preload defect in severe sepsis despite fluid loading: a longitudinal echocardiographic study in patients with septic shock","volume":"116","author":"Jardin","year":"1999","journal-title":"Chest"},{"key":"R27-20230913","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1164\/rccm.200202-146CC","article-title":"Echo\u2013Doppler demonstration of acute cor pulmonale at the bedside in the medical intensive care unit","volume":"166","author":"Vieillard-Baron","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"R28-20230913","doi-asserted-by":"crossref","first-page":"K11","DOI":"10.1530\/ERP-14-0040","article-title":"Diagnostic echocardiography in an unstable intensive care patient","volume":"2","author":"Gray","year":"2015","journal-title":"Echo Res Pract"},{"key":"R29-20230913","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.1097\/CCM.0000000000001847","article-title":"Guidelines for the appropriate use of bedside general and cardiac ultrasonography in the evaluation of critically ill patients \u2013 Part II: Cardiac ultrasonography","volume":"44","author":"Levitov","year":"2016","journal-title":"Crit Care Med"},{"key":"R30-20230913","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1097\/01.ccx.0000224870.24324.cc","article-title":"Echocardiographic measurement of fluid responsiveness","volume":"12","author":"Charron","year":"2006","journal-title":"Curr Opin Crit Care"},{"key":"R31-20230913","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1097\/00000542-200111000-00010","article-title":"Influence of superior vena caval zone condition on cyclic changes in right ventricular outflow during respiratory support","volume":"95","author":"Vieillard-Baron","year":"2001","journal-title":"Anesthesiology"},{"key":"R32-20230913","doi-asserted-by":"crossref","first-page":"1734","DOI":"10.1007\/s00134-004-2474-3","article-title":"Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients","volume":"30","author":"Vieillard-Baron","year":"2004","journal-title":"Intensive Care Med"},{"key":"R33-20230913","first-page":"e893","article-title":"Predicting central venous pressure by measuring femoral venous diameter using ultrasonography","volume":"8","author":"Malik","year":"2016","journal-title":"Cureus"},{"key":"R34-20230913","doi-asserted-by":"crossref","first-page":"2138","DOI":"10.1161\/CIRCULATIONAHA.111.060319","article-title":"Hemodynamics in the cardiac catheterization laboratory of the 21st century","volume":"125","author":"Nishimura","year":"2012","journal-title":"Circulation"},{"key":"R35-20230913","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1001\/jama.1996.03540110043030","article-title":"The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators","volume":"276","author":"Connors","year":"1996","journal-title":"JAMA"},{"key":"R36-20230913","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1056\/NEJMoa021108","article-title":"A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients","volume":"348","author":"Sandham","year":"2003","journal-title":"N Engl J Med"},{"key":"R37-20230913","first-page":"CD003408","article-title":"Pulmonary artery catheters for adult patients in intensive care","author":"Rajaram","year":"2013","journal-title":"Cochrane Database Syst Rev"},{"key":"R38-20230913","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/S0749-0704(05)70279-7","article-title":"Pulmonary artery catheters in the critically ill. An overview using the methodology of evidence-based medicine","volume":"12","author":"Cooper","year":"1996","journal-title":"Crit Care Clin"},{"key":"R39-20230913","doi-asserted-by":"crossref","first-page":"2213","DOI":"10.1056\/NEJMoa061895","article-title":"Pulmonary-artery versus central venous catheter to guide treatment of acute lung injury","volume":"354","author":"Wheeler","year":"2006","journal-title":"N Engl J Med"},{"key":"R40-20230913","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1378\/chest.84.3.245","article-title":"A prospective study of complications of pulmonary artery catheterizations in 500 consecutive patients","volume":"84","author":"Boyd","year":"1983","journal-title":"Chest"},{"key":"R41-20230913","doi-asserted-by":"crossref","first-page":"2546","DOI":"10.1016\/j.jacc.2006.07.061","article-title":"Complications of right heart catheterization procedures in patients with pulmonary hypertension in experienced centers","volume":"48","author":"Hoeper","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"R42-20230913","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1177\/0310057X1204000304","article-title":"The PiCCO monitor: a review","volume":"40","author":"Litton","year":"2012","journal-title":"Anaesth Intensive Care"},{"key":"R43-20230913","doi-asserted-by":"crossref","first-page":"121","DOI":"10.4103\/0971-9784.37937","article-title":"Comparison of simultaneous estimation of cardiac output by four techniques in patients undergoing off-pump coronary artery bypass surgery--a prospective observational study","volume":"10","author":"Chakravarthy","year":"2007","journal-title":"Ann Card Anaesth"},{"key":"R44-20230913","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1007\/s00134-014-3638-4","article-title":"Effectiveness of treatment based on PiCCO parameters in critically ill patients with septic shock and\/or acute respiratory distress syndrome: a randomized controlled trial","volume":"41","author":"Zhang","year":"2015","journal-title":"Intensive Care Med"},{"key":"R45-20230913","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1186\/s13613-016-0217-6","article-title":"ICU management based on PiCCO parameters reduces duration of mechanical ventilation and ICU length of stay in patients with severe thoracic trauma and acute respiratory distress syndrome","volume":"6","author":"Yuanbo","year":"2016","journal-title":"Ann Intensive Care"},{"key":"R46-20230913","doi-asserted-by":"crossref","first-page":"14-014-0732-5","DOI":"10.1186\/s13054-014-0732-5","article-title":"Dynamic arterial elastance predicts mean arterial pressure decrease associated with decreasing norepinephrine dosage in septic shock","volume":"19","author":"Guinot","year":"2015","journal-title":"Crit Care"},{"key":"R47-20230913","doi-asserted-by":"crossref","first-page":"626-014-0626-6","DOI":"10.1186\/s13054-014-0626-6","article-title":"Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study","volume":"18","author":"Garcia","year":"2014","journal-title":"Crit Care"},{"key":"R48-20230913","doi-asserted-by":"crossref","first-page":"2642","DOI":"10.1097\/CCM.0b013e3181a590da","article-title":"Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature","volume":"37","author":"Marik","year":"2009","journal-title":"Crit Care Med"},{"key":"R49-20230913","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1164\/ajrccm.162.1.9903035","article-title":"Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure","volume":"162","author":"Michard","year":"2000","journal-title":"Am J Respir Crit Care Med"},{"key":"R50-20230913","doi-asserted-by":"crossref","first-page":"650-014-0650-6","DOI":"10.1186\/s13054-014-0650-6","article-title":"Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis","volume":"18","author":"Yang","year":"2014","journal-title":"Crit Care"},{"key":"R51-20230913","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1378\/chest.121.4.1245","article-title":"Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients","volume":"121","author":"Boulain","year":"2002","journal-title":"Chest"},{"key":"R52-20230913","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1007\/s00134-008-1067-y","article-title":"Hemodynamic effects of passive leg raising: an echocardiographic study in patients with shock","volume":"34","author":"Caille","year":"2008","journal-title":"Intensive Care Med"},{"key":"R53-20230913","doi-asserted-by":"crossref","first-page":"1935","DOI":"10.1007\/s00134-015-4134-1","article-title":"Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis","volume":"42","author":"Monnet","year":"2016","journal-title":"Intensive Care Med"},{"key":"R54-20230913","doi-asserted-by":"crossref","first-page":"1402","DOI":"10.1097\/01.CCM.0000215453.11735.06","article-title":"Passive leg raising predicts fluid responsiveness in the critically ill","volume":"34","author":"Monnet","year":"2006","journal-title":"Crit Care Med"},{"key":"R55-20230913","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1097\/CCM.0000000000001556","article-title":"Predicting fluid responsiveness by passive leg raising: a systematic review and meta-analysis of 23 clinical trials","volume":"44","author":"Cherpanath","year":"2016","journal-title":"Crit Care Med"},{"key":"R56-20230913","article-title":"Comparison of echocardiographic indices used to predict fluid responsiveness in ventilated patients","author":"Vignon","year":"2016","journal-title":"Am J Respir Crit Care Med"},{"key":"R57-20230913","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1093\/bja\/aet116","article-title":"Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients","volume":"111","author":"Bendjelid","year":"2013","journal-title":"Br J Anaesth"},{"key":"R58-20230913","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1007\/s00134-007-0640-0","article-title":"Noninvasive cardiac output monitoring (NICOM): a clinical validation","volume":"33","author":"Squara","year":"2007","journal-title":"Intensive Care Med"},{"key":"R59-20230913","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1186\/cc10291","article-title":"Clinical review: update on hemodynamic monitoring \u2013 a consensus of 16","volume":"15","author":"Vincent","year":"2011","journal-title":"Crit Care"},{"key":"R60-20230913","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1093\/bja\/aem409","article-title":"Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac\/Vigileo) in haemodynamically unstable patients","volume":"100","author":"Compton","year":"2008","journal-title":"Br J Anaesth"}],"container-title":["Current Opinion in Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00075198-201706000-00010","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T19:07:43Z","timestamp":1694632063000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00075198-201706000-00010"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6]]},"references-count":60,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/mcc.0000000000000407","relation":{},"ISSN":["1070-5295","1531-7072"],"issn-type":[{"value":"1070-5295","type":"print"},{"value":"1531-7072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,6]]}}}