{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T21:26:51Z","timestamp":1761514011257},"reference-count":47,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,8]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>Fluid responsiveness prediction is not always possible with well established dynamic approaches such as passive leg raising or pulse pressure variation in the ICU. The purpose of the present review is to summarize emerging alternative techniques for fluid responsiveness prediction in adult critically ill patients and discuss their methodology and applicability. In addition, the future role of fluid responsiveness prediction in the ICU is discussed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>Several new dynamic techniques have been investigated and they all contribute to the applicability of fluid responsiveness techniques. Although increasing the applicability, most of the emerging techniques still rely on ventilator setting changes in patients that are fully or almost fully adapted to the ventilator or require reliable flow monitoring, which prevents broad applicability. Yet, the mini\/micro fluid challenges and the use of extrasystolic preload changes have the potential of being more applicable but all reviewed methods need further validation and methodological refinement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>Emerging techniques are encouraging for broader applicability of fluid responsiveness prediction. Still, the clinical impact of correctly predicting fluid responsiveness remains to be investigated in the critically ill and the research community should have a clear aim of moving toward that type of studies.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mcc.0000000000000421","type":"journal-article","created":{"date-parts":[[2017,5,23]],"date-time":"2017-05-23T21:04:37Z","timestamp":1495573477000},"page":"318-325","source":"Crossref","is-referenced-by-count":4,"title":["Where are we heading with fluid responsiveness research?"],"prefix":"10.1097","volume":"23","author":[{"given":"Simon T.","family":"Vistisen","sequence":"first","affiliation":[{"name":"Research Centre for Emergency Medicine, Institute of Clinical Medicine, Aarhus University"},{"name":"Department of Anaesthesiology and Intensive Care, Aarhus University Hospital, Aarhus, Denmark"},{"name":"University Medical Center Groningen, University of Groningen, Groningen, the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Juhl-Olsen","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Intensive Care, Aarhus University Hospital, Aarhus, Denmark"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230913","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1007\/s00134-010-1929-y","article-title":"Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies","volume":"36","author":"Cavallaro","year":"2010","journal-title":"Intensive Care Med"},{"key":"R2-20230913","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1097\/CCM.0000000000001556","article-title":"Predicting fluid responsiveness by passive leg raising: a systematic review and meta-analysis of 23 clinical trials","volume":"44","author":"Cherpanath","year":"2016","journal-title":"Crit Care Med"},{"key":"R3-20230913","doi-asserted-by":"crossref","first-page":"2642","DOI":"10.1097\/CCM.0b013e3181a590da","article-title":"Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature","volume":"37","author":"Marik","year":"2009","journal-title":"Crit Care Med"},{"key":"R4-20230913","doi-asserted-by":"crossref","first-page":"1824","DOI":"10.1097\/CCM.0b013e3181eb3c21","article-title":"The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension","volume":"38","author":"Mahjoub","year":"2010","journal-title":"Crit Care Med"},{"key":"R5-20230913","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1097\/CCM.0b013e3181968fe1","article-title":"Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients","volume":"37","author":"Monnet","year":"2009","journal-title":"Crit Care Med"},{"key":"R6-20230913","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1164\/rccm.201604-0844OC","article-title":"Comparison of echocardiographic indices used to predict fluid responsiveness in ventilated patients","volume":"195","author":"Vignon","year":"2017","journal-title":"Am J Respir Crit Care Med"},{"key":"R7-20230913","doi-asserted-by":"crossref","first-page":"1076","DOI":"10.1164\/rccm.201702-2130LE","article-title":"Reply: dynamic indices derived from heart-lung interactions: mitis depone colla","volume":"195","author":"Vignon","year":"2017","journal-title":"Am J Respir Crit Care Med"},{"key":"R8-20230913","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1164\/rccm.201701-0060LE","article-title":"Can passive leg raising be considered the gold standard in predicting fluid responsiveness?","volume":"195","author":"Vistisen","year":"2017","journal-title":"Am J Respir Crit Care Med"},{"key":"R9-20230913","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1097\/00000542-200508000-00026","article-title":"Changes in arterial pressure during mechanical ventilation","volume":"103","author":"Michard","year":"2005","journal-title":"Anesthesiology"},{"key":"R10-20230913","doi-asserted-by":"crossref","first-page":"2570","DOI":"10.1097\/CCM.0b013e3181a380a3","article-title":"Assessing fluid responsiveness in critically ill patients: false-positive pulse pressure variation is detected by Doppler echocardiographic evaluation of the right ventricle","volume":"37","author":"Mahjoub","year":"2009","journal-title":"Crit Care Med"},{"key":"R11-20230913","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1111\/j.1399-6576.2006.01120.x","article-title":"Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation","volume":"50","author":"Perner","year":"2006","journal-title":"Acta Anaesthesiol Scand"},{"key":"R12-20230913","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s00134-005-2586-4","article-title":"Pulse pressure variations to predict fluid responsiveness: influence of tidal volume","volume":"31","author":"De Backer","year":"2005","journal-title":"Intensive Care Med"},{"key":"R13-20230913","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1097\/ALN.0b013e31819db2a1","article-title":"Influence of respiratory rate on stroke volume variation in mechanically ventilated patients","volume":"110","author":"De Backer","year":"2009","journal-title":"Anesthesiology"},{"key":"R14-20230913","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1097\/CCM.0b013e31822f08d7","article-title":"Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance","volume":"40","author":"Monnet","year":"2012","journal-title":"Crit Care Med"},{"key":"R15-20230913","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1093\/bja\/aet442","article-title":"Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study","volume":"112","author":"Mahjoub","year":"2014","journal-title":"Br J Anaesth"},{"key":"R16-20230913","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1097\/CCM.0b013e31828a2323","article-title":"End-expiratory occlusion test predicts preload responsiveness independently of positive end-expiratory pressure during acute respiratory distress syndrome","volume":"41","author":"Silva","year":"2013","journal-title":"Crit Care Med"},{"key":"R17-20230913","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1093\/bja\/aet582","article-title":"End-expiratory occlusion manoeuvre does not accurately predict fluid responsiveness in the operating theatre","volume":"112","author":"Guinot","year":"2014","journal-title":"Br J Anaesth"},{"key":"R18-20230913","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1097\/CCM.0000000000002183","article-title":"The changes in pulse pressure variation or stroke volume variation after a \u2018tidal volume challenge\u2019 reliably predict fluid responsiveness during low tidal volume ventilation","volume":"45","author":"Myatra","year":"2017","journal-title":"Crit Care Med"},{"key":"R19-20230913","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1111\/aas.12229","article-title":"Fluid responsiveness predicted by elevation of PEEP in patients with septic shock","volume":"58","author":"Wilkman","year":"2014","journal-title":"Acta Anaesthesiol Scand"},{"key":"R20-20230913","doi-asserted-by":"crossref","first-page":"e4259","DOI":"10.1097\/MD.0000000000004259","article-title":"Stroke volume changes induced by a recruitment maneuver predict fluid responsiveness in patients with protective ventilation in the operating theater","volume":"95","author":"De Broca","year":"2016","journal-title":"Medicine (Baltimore)"},{"key":"R21-20230913","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1097\/ALN.0000000000001459","article-title":"Changes in stroke volume induced by lung recruitment maneuver predict fluid responsiveness in mechanically ventilated patients in the operating room","volume":"126","author":"Biais","year":"2017","journal-title":"Anesthesiology"},{"key":"R22-20230913","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1007\/s00134-008-1295-1","article-title":"Arterial pressure changes during the Valsalva maneuver to predict fluid responsiveness in spontaneously breathing patients","volume":"35","author":"Monge Garcia","year":"2009","journal-title":"Intensive Care Med"},{"key":"R23-20230913","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1097\/EJA.0000000000000613","article-title":"Evaluation of augmented pulse pressure variation using the Valsalva manoeuvre as a predictor of fluid responsiveness under open-chest conditions: a prospective observational study","volume":"34","author":"Min","year":"2017","journal-title":"Eur J Anaesthesiol"},{"key":"R24-20230913","article-title":"Using extra systoles to predict fluid responsiveness in cardiothoracic critical care patients","author":"Vistisen","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"R25-20230913","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1097\/ALN.0b013e318229a500","article-title":"An increase in aortic blood flow after an infusion of 100 ml colloid over 1 min can predict fluid responsiveness: the mini-fluid challenge study","volume":"115","author":"Muller","year":"2011","journal-title":"Anesthesiology"},{"key":"R26-20230913","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1093\/bja\/aev222","article-title":"Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness","volume":"115","author":"Mallat","year":"2015","journal-title":"Br J Anaesth"},{"key":"R27-20230913","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1097\/EJA.0000000000000175","article-title":"Mini-fluid challenge predicts fluid responsiveness during spontaneous breathing under spinal anaesthesia: an observational study","volume":"32","author":"Guinot","year":"2015","journal-title":"Eur J Anaesthesiol"},{"key":"R28-20230913","doi-asserted-by":"crossref","first-page":"R108","DOI":"10.1186\/cc13891","article-title":"A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness","volume":"18","author":"Wu","year":"2014","journal-title":"Crit Care"},{"key":"R29-20230913","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1093\/bja\/aeu430","article-title":"End-expiratory occlusion test: please use the appropriate tools!","volume":"114","author":"Monnet","year":"2015","journal-title":"Br J Anaesth"},{"key":"R30-20230913","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/S0140-6736(09)62072-9","article-title":"A protocol of no sedation for critically ill patients receiving mechanical ventilation: a randomised trial","volume":"375","author":"Strom","year":"2010","journal-title":"Lancet"},{"key":"R31-20230913","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1007\/s10877-013-9528-4","article-title":"Variations in the preejection period induced by ventricular extra systoles may be feasible to predict fluid responsiveness","volume":"28","author":"Vistisen","year":"2014","journal-title":"J Clin Monit Comput"},{"key":"R32-20230913","doi-asserted-by":"crossref","first-page":"191807","DOI":"10.1155\/2012\/191807","article-title":"Hemodynamic changes during a deep inspiration maneuver predict fluid responsiveness in spontaneously breathing patients","volume":"2012","author":"Preau","year":"2012","journal-title":"Cardiol Res Pract"},{"key":"R33-20230913","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/s10877-013-9526-6","article-title":"Variations in the preejection period induced by deep breathing do not predict the hemodynamic response to early haemorrhage in healthy volunteers","volume":"28","author":"Vistisen","year":"2014","journal-title":"J Clin Monit Comput"},{"key":"R34-20230913","doi-asserted-by":"crossref","first-page":"e0137364","DOI":"10.1371\/journal.pone.0137364","article-title":"Arterial pressure variation as a biomarker of preload dependency in spontaneously breathing subjects: a proof of principle","volume":"10","author":"Bronzwaer","year":"2015","journal-title":"PLoS One"},{"key":"R35-20230913","doi-asserted-by":"crossref","first-page":"R39","DOI":"10.1186\/cc7760","article-title":"Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study","volume":"13","author":"Dahl","year":"2009","journal-title":"Crit Care"},{"key":"R36-20230913","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1186\/s12871-016-0224-z","article-title":"Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?","volume":"16","author":"Dahl","year":"2016","journal-title":"BMC Anesthesiol"},{"key":"R37-20230913","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.1007\/s00134-015-3850-x","article-title":"Fluid challenges in intensive care: the FENICE study: a global inception cohort study","volume":"41","author":"Cecconi","year":"2015","journal-title":"Intensive Care Med"},{"key":"R38-20230913","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1093\/bja\/aev349","article-title":"A rational approach to fluid therapy in sepsis","volume":"116","author":"Marik","year":"2016","journal-title":"Br J Anaesth"},{"key":"R39-20230913","doi-asserted-by":"crossref","first-page":"R15","DOI":"10.1186\/cc9420","article-title":"Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients","volume":"15","author":"Monge Garcia","year":"2011","journal-title":"Crit Care"},{"key":"R40-20230913","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1213\/ANE.0000000000000442","article-title":"The use of pulse pressure variation and stroke volume variation in spontaneously breathing patients to assess dynamic arterial elastance and to predict arterial pressure response to fluid administration","volume":"120","author":"Cecconi","year":"2015","journal-title":"Anesth Analg"},{"key":"R41-20230913","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1093\/bja\/aes508","article-title":"Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection","volume":"110","author":"Vos","year":"2013","journal-title":"Br J Anaesth"},{"key":"R42-20230913","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/s13054-014-0734-3","article-title":"Preload dependence indices to titrate volume expansion during septic shock: a randomized controlled trial","volume":"19","author":"Richard","year":"2015","journal-title":"Crit Care"},{"key":"R43-20230913","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1213\/ANE.0b013e3181eeaae5","article-title":"A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients","volume":"112","author":"Hamilton","year":"2011","journal-title":"Anesth Analg"},{"key":"R44-20230913","doi-asserted-by":"crossref","first-page":"2181","DOI":"10.1001\/jama.2014.5305","article-title":"Effect of a perioperative, cardiac output-guided hemodynamic therapy algorithm on outcomes following major gastrointestinal surgery: a randomized clinical trial and systematic review","volume":"311","author":"Pearse","year":"2014","journal-title":"JAMA"},{"key":"R45-20230913","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1056\/NEJMoa1404380","article-title":"Goal-directed resuscitation for patients with early septic shock","volume":"371","author":"Peake","year":"2014","journal-title":"N Engl J Med"},{"key":"R46-20230913","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1056\/NEJMoa1401602","article-title":"A randomized trial of protocol-based care for early septic shock","volume":"370","author":"Yealy","year":"2014","journal-title":"N Engl J Med"},{"key":"R47-20230913","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1056\/NEJMoa1500896","article-title":"Trial of early, goal-directed resuscitation for septic shock","volume":"372","author":"Mouncey","year":"2015","journal-title":"N Engl J Med"}],"container-title":["Current Opinion in Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00075198-201708000-00012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T19:11:47Z","timestamp":1694632307000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00075198-201708000-00012"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8]]},"references-count":47,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/mcc.0000000000000421","relation":{},"ISSN":["1070-5295","1531-7072"],"issn-type":[{"value":"1070-5295","type":"print"},{"value":"1531-7072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,8]]}}}