{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T01:25:17Z","timestamp":1792027517678,"version":"4.4.0"},"reference-count":48,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,6]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose of review<\/jats:title>\n                    <jats:p>To discuss the suitable haemodynamic monitoring for critically ill patients with shock.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Recent findings<\/jats:title>\n                    <jats:p>For the basic initial monitoring, recent studies emphasized the importance of clinical signs of hypoperfusion and arterial pressure. This basic monitoring is not sufficient in patients resisting to initial treatment. Echocardiography does not allow multidaily measurements and has limitations, for measuring right or left ventricular preload. For a more continuous monitoring, noninvasive and minimally invasive tools are insufficiently reliable, as recently confirmed, and informative. The most invasive techniques, transpulmonary thermodilution and the pulmonary arterial catheter are more suitable. Their effect on outcome is lacking, although recent studies showed their benefit in acute heart failure. For assessing tissue oxygenation, recent publications better defined the meaning of the indices derived from the partial pressure of carbon dioxide. The integration of all data by artificial intelligence is the subject of early research in critical care.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary<\/jats:title>\n                    <jats:p>For monitoring critically ill patients with shock, minimally or noninvasive systems are not reliable or informative enough. In the most severe patients, a reasonable monitoring policy can combine continuous monitoring by transpulmonary thermodilution systems or the pulmonary arterial catheter, with an intermittent assessment with ultrasound and measurement of tissue oxygenation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/mcc.0000000000001048","type":"journal-article","created":{"date-parts":[[2023,4,20]],"date-time":"2023-04-20T17:47:26Z","timestamp":1682012846000},"page":"275-280","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Which haemodynamic monitoring should we chose for critically ill patients with acute circulatory failure?"],"prefix":"10.1097","volume":"29","author":[{"given":"Xavier","family":"Monnet","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Lai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,4,19]]},"reference":[{"key":"R1-20250729","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1007\/s00134-022-06798-8","article-title":"Invasive arterial pressure monitoring: much more than mean arterial pressure!","volume":"48","author":"Hernandez","year":"2022","journal-title":"Intensive Care Med"},{"key":"R2-20250729","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/s13613-020-00658-8","article-title":"Diastolic shock index and clinical outcomes in patients with septic shock","volume":"10","author":"Ospina-Tascon","year":"2020","journal-title":"Ann Intensive Care"},{"key":"R3-20250729","doi-asserted-by":"crossref","first-page":"176","DOI":"10.15441\/ceem.22.324","article-title":"Prediction of vasopressor requirement among hypotensive patients with suspected infection: usefulness of diastolic shock index and lactate","volume":"9","author":"Kim","year":"2022","journal-title":"Clin Exp Emerg Med"},{"key":"R4-20250729","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1186\/s13054-022-04236-1","article-title":"Higher blood pressure versus normotension targets to prevent acute kidney injury: a systematic review and meta-regression of randomized controlled trials","volume":"26","author":"Tran","year":"2022","journal-title":"Crit Care"},{"key":"R5-20250729","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1186\/s13054-021-03515-7","article-title":"Do changes in pulse pressure variation and inferior vena cava distensibility during passive leg raising and tidal volume challenge detect preload responsiveness in case of low tidal volume ventilation?","volume":"25","author":"Taccheri","year":"2021","journal-title":"Crit Care"},{"key":"R6-20250729","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.bja.2022.04.031","article-title":"Passive leg raising-induced changes in pulse pressure variation to assess fluid responsiveness in mechanically ventilated patients: a multicentre prospective observational study","volume":"129","author":"Mallat","year":"2022","journal-title":"Br J Anaesth"},{"key":"R7-20250729","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1186\/s13054-023-04336-6","article-title":"Does tidal volume challenge improve the feasibility of pulse pressure variation in patients mechanically ventilated at low tidal volumes? A systematic review and meta-analysis","volume":"27","author":"Wang","year":"2023","journal-title":"Crit Care"},{"key":"R8-20250729","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1186\/s13054-022-04087-w","article-title":"Tidal volume challenge to predict preload responsiveness in patients with acute respiratory distress syndrome under prone position","volume":"26","author":"Shi","year":"2022","journal-title":"Crit Care"},{"key":"R9-20250729","doi-asserted-by":"crossref","first-page":"1498","DOI":"10.1007\/s00134-022-06835-6","article-title":"Central venous pressure (CVP)","volume":"48","author":"Hamzaoui","year":"2022","journal-title":"Intensive Care Med"},{"key":"R10-20250729","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1186\/s12882-022-02715-9","article-title":"Central venous pressure and acute kidney injury in critically ill patients with multiple comorbidities: a large retrospective cohort study","volume":"23","author":"Sun","year":"2022","journal-title":"BMC Nephrol"},{"key":"R11-20250729","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1186\/2110-5820-3-31","article-title":"Alteration of skin perfusion in mottling area during septic shock","volume":"3","author":"Ait-Oufella","year":"2013","journal-title":"Ann Intensive Care"},{"key":"R12-20250729","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1001\/jama.2019.0071","article-title":"Effect of a resuscitation strategy targeting peripheral perfusion status vs serum lactate levels on 28-day mortality among patients with septic shock: the ANDROMEDA-SHOCK randomized clinical trial","volume":"321","author":"Hernandez","year":"2019","journal-title":"JAMA"},{"key":"R13-20250729","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/s13054-018-1957-5","article-title":"Cardiac output monitoring: throw it out... or keep it?","volume":"22","author":"Monnet","year":"2018","journal-title":"Crit Care"},{"key":"R14-20250729","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1186\/s13613-018-0400-z","article-title":"My patient has received fluid. How to assess its efficacy and side effects?","volume":"8","author":"Monnet","year":"2018","journal-title":"Ann Intensive Care"},{"key":"R15-20250729","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/s00134-019-05527-y","article-title":"The diagnostic accuracy of clinical examination for estimating cardiac index in critically ill patients: the Simple Intensive Care Studies-I","volume":"45","author":"Hiemstra","year":"2019","journal-title":"Intensive Care Med"},{"key":"R16-20250729","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1007\/s00134-014-3525-z","article-title":"Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine","volume":"40","author":"Cecconi","year":"2014","journal-title":"Intensive Care Med"},{"key":"R17-20250729","first-page":"432","article-title":"New developments in continuous hemodynamic monitoring of the critically ill patient","volume":"39","author":"Couture","year":"2023","journal-title":"Can J Cardiol"},{"key":"R18-20250729","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1097\/CCM.0000000000004702","article-title":"Doppler echocardiographic indices are specific but not sensitive to predict pulmonary artery occlusion pressure in critically ill patients under mechanical ventilation","volume":"49","author":"Mercado","year":"2021","journal-title":"Crit Care Med"},{"key":"R19-20250729","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1007\/s00134-018-5067-2","article-title":"Limited value of end-expiratory inferior vena cava diameter to predict fluid responsiveness impact of intra-abdominal pressure","volume":"44","author":"Vieillard-Baron","year":"2018","journal-title":"Intensive Care Med"},{"key":"R20-20250729","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.bja.2020.09.049","article-title":"Cardiac output estimation using pulse wave analysis-physiology, algorithms, and technologies: a narrative review","volume":"126","author":"Saugel","year":"2021","journal-title":"Br J Anaesth"},{"key":"R21-20250729","doi-asserted-by":"crossref","first-page":"6093","DOI":"10.3390\/jcm11206093","article-title":"Comparison between fourth-generation FloTrac\/Vigileo system and continuous thermodilution technique for cardiac output estimation after time adjustment during off-pump coronary artery bypass graft surgery: a retrospective cohort study","volume":"11","author":"Oh","year":"2022","journal-title":"J Clin Med"},{"key":"R22-20250729","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1007\/s00380-022-02177-x","article-title":"Validation of cardiac output estimation using the fourth-generation FloTrac\/EV1000 system in patients undergoing robotic-assisted off-pump coronary artery bypass surgery","volume":"38","author":"Wu","year":"2023","journal-title":"Heart Vessels"},{"key":"R23-20250729","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1186\/s13019-023-02128-1","article-title":"Study of the accuracy of a radial arterial pressure waveform cardiac output measurement device after cardiac surgery","volume":"18","author":"Ordonez-Rufat","year":"2023","journal-title":"J Cardiothorac Surg"},{"key":"R24-20250729","doi-asserted-by":"crossref","first-page":"11198","DOI":"10.1038\/s41598-022-14988-z","article-title":"Agreement between continuous cardiac output measured by the fourth-generation FloTrac\/Vigileo system and a pulmonary artery catheter in adult liver transplantation","volume":"12","author":"Murata","year":"2022","journal-title":"Sci Rep"},{"key":"R25-20250729","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1186\/s12871-023-01988-3","article-title":"Reliability of bioreactance and pulse power analysis in measuring cardiac index during cytoreductive abdominal surgery with hyperthermic intraperitoneal chemotherapy (HIPEC)","volume":"23","author":"Ylikauma","year":"2023","journal-title":"BMC Anesthesiol"},{"key":"R26-20250729","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.bja.2020.03.013","article-title":"Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: a systematic review and meta-analysis","volume":"125","author":"Saugel","year":"2020","journal-title":"Br J Anaesth"},{"key":"R27-20250729","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s13613-022-01022-8","article-title":"Prediction of fluid responsiveness. What's new?","volume":"12","author":"Monnet","year":"2022","journal-title":"Ann Intensive Care"},{"key":"R28-20250729","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1007\/s10877-021-00662-8","article-title":"The contemporary pulmonary artery catheter. Part 1: Placement and waveform analysis","volume":"36","author":"Bootsma","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"R29-20250729","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s10877-021-00673-5","article-title":"The contemporary pulmonary artery catheter. Part 2: Measurements, limitations, and clinical applications","volume":"36","author":"Bootsma","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"R30-20250729","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1186\/s13054-021-03523-7","article-title":"Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis","volume":"25","author":"Kouz","year":"2021","journal-title":"Crit Care"},{"key":"R31-20250729","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1186\/s13054-021-03671-w","article-title":"Pathophysiology and clinical implications of the veno-arterial PCO(2) gap","volume":"25","author":"Ltaief","year":"2021","journal-title":"Crit Care"},{"key":"R32-20250729","doi-asserted-by":"crossref","first-page":"S1528","DOI":"10.21037\/jtd.2019.07.10","article-title":"How can CO2-derived indices guide resuscitation in critically ill patients?","volume":"11","author":"Gavelli","year":"2019","journal-title":"J Thorac Dis"},{"key":"R33-20250729","doi-asserted-by":"crossref","first-page":"e0257314","DOI":"10.1371\/journal.pone.0257314","article-title":"Changes in central venous-to-arterial carbon dioxide tension induced by fluid bolus in critically ill patients","volume":"16","author":"Pierrakos","year":"2021","journal-title":"PLoS One"},{"key":"R34-20250729","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1186\/s12871-023-01993-6","article-title":"Ratio of carbon dioxide veno-arterial difference to oxygen arterial-venous difference is not associated with lactate decrease after fluid bolus in critically ill patients with hyperlactatemia: results from a prospective observational study","volume":"23","author":"Kaefer","year":"2023","journal-title":"BMC Anesthesiol"},{"key":"R35-20250729","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1186\/s13054-022-04061-6","article-title":"Extravascular lung water levels are associated with mortality: a systematic review and meta-analysis","volume":"26","author":"Gavelli","year":"2022","journal-title":"Crit Care"},{"key":"R36-20250729","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1186\/s12967-022-03793-x","article-title":"Diagnostic value of transpulmonary thermodilution measurements for acute respiratory distress syndrome in a pig model of septic shock","volume":"20","author":"Endo","year":"2022","journal-title":"J Transl Med"},{"key":"R37-20250729","doi-asserted-by":"crossref","first-page":"1663","DOI":"10.1053\/j.jvca.2020.11.012","article-title":"Comparison of right ventricular function between three-dimensional transesophageal echocardiography and pulmonary artery catheter","volume":"35","author":"Yano","year":"2021","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R38-20250729","doi-asserted-by":"crossref","first-page":"2200879","DOI":"10.1183\/13993003.00879-2022","article-title":"2022 ESC\/ERS guidelines for the diagnosis and treatment of pulmonary hypertension","volume":"61","author":"Humbert","year":"2023","journal-title":"Eur Respir J"},{"key":"R39-20250729","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1007\/s10877-022-00931-0","article-title":"Effects of changes in veno-venous extracorporeal membrane oxygenation blood flow on the measurement of intrathoracic blood volume and extravascular lung water index: a prospective interventional study","volume":"37","author":"Conrad","year":"2023","journal-title":"J Clin Monit Comput"},{"key":"R40-20250729","doi-asserted-by":"crossref","first-page":"889190","DOI":"10.3389\/fphys.2022.889190","article-title":"Cardiac output monitoring with pulmonary versus trans-cardiopulmonary thermodilution in left ventricular assist devices: interchangeable methods?","volume":"13","author":"Quintana-Villamandos","year":"2022","journal-title":"Front Physiol"},{"key":"R41-20250729","doi-asserted-by":"crossref","first-page":"e100549","DOI":"10.1136\/bmjhci-2022-100549","article-title":"Assuring the safety of AI-based clinical decision support systems: a case study of the AI Clinician for sepsis treatment","volume":"29","author":"Festor","year":"2022","journal-title":"BMJ Healthcare Inform"},{"key":"R42-20250729","first-page":"8604322","article-title":"Effect of pulse indicator continuous cardiac output monitoring on septic shock patients: a meta-analysis","volume":"2022","author":"Wang","year":"2022","journal-title":"Comput Math Methods Med"},{"key":"R43-20250729","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1186\/s13054-022-04173-z","article-title":"Effective hemodynamic monitoring","volume":"26","author":"Pinsky","year":"2022","journal-title":"Crit Care"},{"key":"R44-20250729","first-page":"454","article-title":"Hemodynamic monitoring in cardiogenic shock","volume":"27","author":"VanDyck","year":"2021","journal-title":"Curr Opin Crit Care"},{"key":"R45-20250729","doi-asserted-by":"crossref","first-page":"e15","DOI":"10.15420\/cfr.2021.32","article-title":"Pulmonary artery catheter monitoring in patients with cardiogenic shock: time for a reappraisal?","volume":"8","author":"Bertaina","year":"2022","journal-title":"Card Fail Rev"},{"key":"R46-20250729","doi-asserted-by":"crossref","first-page":"154024","DOI":"10.1016\/j.jcrc.2022.154024","article-title":"Prognostic implications of pulmonary artery catheter monitoring in patients with cardiogenic shock: a systematic review and meta-analysis of observational studies","volume":"69","author":"Bertaina","year":"2022","journal-title":"J Crit Care"},{"key":"R47-20250729","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1016\/j.jchf.2020.08.012","article-title":"Complete hemodynamic profiling with pulmonary artery catheters in cardiogenic shock is associated with lower in-hospital mortality","volume":"8","author":"Garan","year":"2020","journal-title":"JACC Heart Fail"},{"key":"R48-20250729","doi-asserted-by":"crossref","first-page":"2780","DOI":"10.1053\/j.jvca.2021.08.021","article-title":"The pulmonary artery catheter in cardiogenic and post-cardiotomy shock-analysis of recent data","volume":"36","author":"Stawiarski","year":"2022","journal-title":"J Cardiothorac Vasc Anesth"}],"container-title":["Current Opinion in Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MCC.0000000000001048","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,29]],"date-time":"2025-07-29T20:09:02Z","timestamp":1753819742000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MCC.0000000000001048"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,19]]},"references-count":48,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/mcc.0000000000001048","relation":{},"ISSN":["1070-5295","1531-7072"],"issn-type":[{"value":"1070-5295","type":"print"},{"value":"1531-7072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,19]]}}}