{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T19:49:29Z","timestamp":1780688969821,"version":"3.54.1"},"reference-count":58,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>Venous pressure is an often-unrecognized cause of patient morbidity. However, bedside assessment of PV is challenging. We review the clinical significance of venous pressure measurement, existing techniques, and introduce the Venous Excess Ultrasound (VExUS) Score as a novel approach using doppler ultrasound to assess venous pressure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>Studies show clear associations between elevated venous pressure and adverse outcomes in critically ill patients. Current venous pressure measurement techniques include physical examination, right heart catheterization (RHC), two-dimensional ultrasound, and a variety of labor-intensive research-focused physiological maneuvers. Each of these techniques have specific shortcomings, limiting their clinical utility. To address these gaps, Beaubien-Souligny <jats:italic toggle=\"yes\">et al.<\/jats:italic> introduced the VExUS Score, a novel doppler ultrasound-based method that integrates IVC diameter with doppler measurements of the hepatic, portal, and renal veins to generate a venous congestion assesment. Studies show strong correlations between VExUS score and RHC measurements, and well as an association between VExUS score and improvement in cardiorenal acute kidney injury, diuretic response, and fluid status shifts. However, studies in noncardiac populations have been small, heterogenous, and inconclus<\/jats:p>\n            <jats:p>ive.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>Early studies evaluating the use of doppler ultrasound to assess venous congestion show promise, but further research is needed in diverse patient populations and clinical settings.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mcc.0000000000001155","type":"journal-article","created":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T10:01:48Z","timestamp":1714557708000},"page":"260-267","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Monitoring the venous circulation: novel techniques and applications"],"prefix":"10.1097","volume":"30","author":[{"given":"August A.","family":"Longino","sequence":"first","affiliation":[{"name":"Department of Internal Medicine, University of Colorado Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katharine C.","family":"Martin","sequence":"additional","affiliation":[{"name":"University of Colorado School of Medicine, University of Colorado"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivor S.","family":"Douglas","sequence":"additional","affiliation":[{"name":"Department of Pulmonary and Critical Care Medicine, Denver Health Medical Center, Denver, CO, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,3,28]]},"reference":[{"key":"R1-20250729","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1152\/advan.00182.2018","article-title":"Understanding basic vein physiology and venous blood pressure through simple physical assessments","volume":"43","author":"Tansey","year":"2019","journal-title":"Adv Physiol Educ"},{"key":"R2-20250729","doi-asserted-by":"crossref","first-page":"1862","DOI":"10.1097\/CCM.0000000000004617","article-title":"Fluid overload and mortality in adult critical care patients-a systematic review and meta-analysis of observational studies","volume":"48","author":"Messmer","year":"2020","journal-title":"Crit Care Med"},{"key":"R3-20250729","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1113\/jphysiol.1931.sp002761","article-title":"The influence of venous pressure on the isolated mammalian kidney","volume":"72","author":"Winton","year":"1931","journal-title":"J Physiol"},{"key":"R4-20250729","doi-asserted-by":"crossref","first-page":"e009961","DOI":"10.1161\/JAHA.118.009961","article-title":"Alterations in portal vein flow and intrarenal venous flow are associated with acute kidney injury after cardiac surgery: a prospective observational cohort study","volume":"7","author":"Beaubien-Souligny","year":"2018","journal-title":"J Am Heart Assoc"},{"key":"R5-20250729","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1038\/s41569-020-0379-7","article-title":"Congestion in heart failure: a contemporary look at physiology, diagnosis and treatment","volume":"17","author":"Boorsma","year":"2020","journal-title":"Nat Rev Cardiol"},{"key":"R6-20250729","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1186\/s13054-020-2770-5","article-title":"Elevated central venous pressure is associated with increased mortality and acute kidney injury in critically ill patients: a meta-analysis","volume":"24","author":"Chen","year":"2020","journal-title":"Crit Care"},{"key":"R7-20250729","doi-asserted-by":"crossref","first-page":"602","DOI":"10.2215\/CJN.08080715","article-title":"Peripheral edema, central venous pressure, and risk of AKI in critical illness","volume":"11","author":"Chen","year":"2016","journal-title":"Clin J Am Soc Nephrol"},{"key":"R8-20250729","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1186\/s13613-017-0306-1","article-title":"Association between elevated central venous pressure and outcomes in critically ill patients","volume":"7","author":"Li","year":"2017","journal-title":"Ann Intensive Care"},{"key":"R9-20250729","doi-asserted-by":"crossref","first-page":"e002922","DOI":"10.1161\/CIRCHEARTFAILURE.115.002922","article-title":"Fluid volume overload and congestion in heart failure: time to reconsider pathophysiology and how volume is assessed","volume":"9","author":"Miller","year":"2016","journal-title":"Circ Heart Fail"},{"key":"R10-20250729","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.jacc.2008.05.068","article-title":"Importance of venous congestion for worsening of renal function in advanced decompensated heart failure","volume":"53","author":"Mullens","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"R11-20250729","doi-asserted-by":"crossref","first-page":"1998","DOI":"10.1038\/s41591-023-02474-6","article-title":"Tissue perfusion pressure enables continuous hemodynamic evaluation and risk prediction in the intensive care unit","volume":"29","author":"Chandrasekhar","year":"2023","journal-title":"Nat Med"},{"key":"R12-20250729","doi-asserted-by":"crossref","first-page":"154070","DOI":"10.1016\/j.jcrc.2022.154070","article-title":"The emerging concept of fluid tolerance: a position paper","volume":"71","author":"Kattan","year":"2022","journal-title":"J Crit Care"},{"key":"R13-20250729","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1186\/s13054-016-1438-7","article-title":"Volume and its relationship to cardiac output and venous return","volume":"20","author":"Magder","year":"2016","journal-title":"Crit Care"},{"key":"R14-20250729","doi-asserted-by":"crossref","first-page":"1272","DOI":"10.1161\/HYPERTENSIONAHA.118.11998","article-title":"Assessing the validity and utility of the Guyton model of arterial blood pressure control","volume":"72","author":"Beard","year":"2018","journal-title":"Hypertension"},{"key":"R15-20250729","doi-asserted-by":"crossref","first-page":"52","DOI":"10.15441\/ceem.16.128","article-title":"Stressed vs. unstressed volume and its relevance to critical care practitioners","volume":"3","author":"Spiegel","year":"2016","journal-title":"Clin Exp Emerg Med"},{"key":"R16-20250729","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1159\/000526902","article-title":"Diagnosis of fluid overload: from conventional to contemporary concepts","volume":"12","author":"Koratala","year":"2022","journal-title":"Cardiorenal Med"},{"key":"R17-20250729","first-page":"e15253","article-title":"The conundrum of volume status assessment: revisiting current and future tools available for physicians at the bedside","volume":"13","author":"Elhassan","year":"2021","journal-title":"Cureus"},{"key":"R18-20250729","doi-asserted-by":"crossref","first-page":"1944","DOI":"10.1001\/jama.294.15.1944","article-title":"Does this dyspneic patient in the emergency department have congestive heart failure?","volume":"294","author":"Wang","year":"2005","journal-title":"JAMA"},{"key":"R19-20250729","first-page":"122","article-title":"Right heart catheterization in clinical practice: a review of basic physiology and important issues relevant to interpretation","volume":"13","author":"Del Rio-Pertuz","year":"2023","journal-title":"Am J Cardiovasc Dis"},{"key":"R20-20250729","doi-asserted-by":"crossref","first-page":"E1331","DOI":"10.3390\/jcm8091331","article-title":"Right heart catheterization-background, physiological basics, and clinical implications","volume":"8","author":"Kubiak","year":"2019","journal-title":"J Clin Med"},{"key":"R21-20250729","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1093\/eurjhf\/hfq045","article-title":"Assessing and grading congestion in acute heart failure: a scientific statement from the acute heart failure committee of the heart failure association of the European Society of Cardiology and endorsed by the European Society of Intensive Care Medicine","volume":"12","author":"Gheorghiade","year":"2010","journal-title":"Eur J Heart Fail"},{"key":"R22-20250729","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1186\/s13613-018-0418-2","article-title":"Estimating mean circulatory filling pressure in clinical practice: a systematic review comparing three bedside methods in the critically ill","volume":"8","author":"Wijnberge","year":"2018","journal-title":"Ann Intensive Care"},{"key":"R23-20250729","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1097\/CCM.0b013e3181961481","article-title":"Assessment of venous return curve and mean systemic filling pressure in postoperative cardiac surgery patients","volume":"37","author":"Maas","year":"2009","journal-title":"Crit Care Med"},{"key":"R24-20250729","doi-asserted-by":"crossref","first-page":"1452","DOI":"10.1007\/s00134-012-2586-0","article-title":"Estimation of mean systemic filling pressure in postoperative cardiac surgery patients with three methods","volume":"38","author":"Maas","year":"2012","journal-title":"Intensive Care Med"},{"key":"R25-20250729","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/s10877-020-00636-2","article-title":"Clinical validation of a computerized algorithm to determine mean systemic filling pressure","volume":"36","author":"Meijs","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"R26-20250729","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/s10877-015-9682-y","article-title":"Transient stop-flow arm arterial-venous equilibrium pressure measurement: determination of precision of the technique","volume":"30","author":"Aya","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"R27-20250729","doi-asserted-by":"crossref","first-page":"e161","DOI":"10.1097\/CCM.0000000000002067","article-title":"Hemodynamic effect of different doses of fluids for a fluid challenge: a quasi-randomized controlled study","volume":"45","author":"Aya","year":"2017","journal-title":"Crit Care Med"},{"key":"R28-20250729","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1097\/EJA.0b013e32834a67d2","article-title":"Arm occlusion pressure is a useful predictor of an increase in cardiac output after fluid loading following cardiac surgery","volume":"28","author":"Geerts","year":"2011","journal-title":"Eur J Anaesthesiol"},{"key":"R29-20250729","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1590\/1677-5449.002116","article-title":"The clinical importance of air plethysmography in the assessment of chronic venous disease","volume":"15","author":"Dezotti","year":"2016","journal-title":"J Vasc Bras"},{"key":"R30-20250729","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1046\/j.0306-5251.2001.01495.x","article-title":"Venous occlusion plethysmography in cardiovascular research: methodology and clinical applications","volume":"52","author":"Wilkinson","year":"2001","journal-title":"Br J Clin Pharmacol"},{"key":"R31-20250729","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/j.avsg.2013.02.025","article-title":"Diagnosis and whole body screening using blood pool scintigraphy for evaluating congenital vascular malformations","volume":"28","author":"Kim","year":"2014","journal-title":"Ann Vasc Surg"},{"key":"R32-20250729","doi-asserted-by":"crossref","first-page":"1545","DOI":"10.1016\/j.jvsv.2021.03.022","article-title":"Comparison of intravascular ultrasound and multidimensional contrast imaging modalities for characterization of chronic occlusive iliofemoral venous disease: A systematic review","volume":"9","author":"Saleem","year":"2021","journal-title":"J Vasc Surg Venous Lymphat Disord"},{"key":"R33-20250729","doi-asserted-by":"crossref","first-page":"65","DOI":"10.24908\/pocus.v7iKidney.15023","article-title":"Integrative volume status assessment","volume":"7","author":"Kearney","year":"2022","journal-title":"POCUS J"},{"key":"R34-20250729","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1001\/jamacardio.2018.0001","article-title":"Time to add a fifth pillar to bedside physical examination: inspection, palpation, percussion, auscultation, and insonation","volume":"3","author":"Narula","year":"2018","journal-title":"JAMA Cardiol"},{"key":"R35-20250729","doi-asserted-by":"crossref","first-page":"e190703","DOI":"10.1001\/jamanetworkopen.2019.0703","article-title":"Diagnostic accuracy of point-of-care lung ultrasonography and chest radiography in adults with symptoms suggestive of acute decompensated heart failure: a systematic review and meta-analysis","volume":"2","author":"Maw","year":"2019","journal-title":"JAMA Netw Open"},{"key":"R36-20250729","doi-asserted-by":"crossref","first-page":"2217","DOI":"10.3390\/jcm12062217","article-title":"Inferior vena cava ultrasonography for volume status evaluation: an intriguing promise never fulfilled","volume":"12","author":"Di Nicolo","year":"2023","journal-title":"J Clin Med"},{"key":"R37-20250729","doi-asserted-by":"crossref","first-page":"344","DOI":"10.7326\/M21-2781","article-title":"Accuracy of ultrasound jugular venous pressure height in predicting central venous congestion","volume":"175","author":"Wang","year":"2022","journal-title":"Ann Intern Med"},{"key":"R38-20250729","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1007\/s40477-022-00654-7","article-title":"Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease","volume":"25","author":"Jenkins","year":"2022","journal-title":"J Ultrasound"},{"key":"R39-20250729","first-page":"39","article-title":"Role of internal jugular vein ultrasound measurements in the assessment of central venous pressure in spontaneously breathing patients: a systematic review","volume":"9","author":"Parenti","year":"2019","journal-title":"J Acute Med"},{"key":"R40-20250729","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/s13089-020-00163-w","article-title":"Quantifying systemic congestion with Point-Of-Care ultrasound: development of the venous excess ultrasound grading system","volume":"12","author":"Beaubien-Souligny","year":"2020","journal-title":"Ultrasound J"},{"key":"R41-20250729","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1148\/radiology.176.3.2202011","article-title":"The pulsatile portal vein in cases of congestive heart failure: correlation of duplex Doppler findings with right atrial pressures","volume":"176","author":"Duerinckx","year":"1990","journal-title":"Radiology"},{"key":"R42-20250729","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/j.jchf.2016.03.016","article-title":"Clinical implications of intrarenal hemodynamic evaluation by Doppler ultrasonography in heart failure","volume":"4","author":"Iida","year":"2016","journal-title":"JACC Heart Fail"},{"key":"R43-20250729","doi-asserted-by":"crossref","first-page":"100482","DOI":"10.1016\/j.xkme.2022.100482","article-title":"Venous excess Doppler ultrasound for the nephrologist: pearls and pitfalls","volume":"4","author":"Koratala","year":"2022","journal-title":"Kidney Med"},{"key":"R44-20250729","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.echo.2015.09.012","article-title":"Echocardiographic correlates of abnormal liver tests in patients with exacerbation of chronic heart failure","volume":"29","author":"Styczynski","year":"2016","journal-title":"J Am Soc Echocardiogr"},{"key":"R45-20250729","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1053\/j.ackd.2021.03.004","article-title":"VExUS Nexus: bedside assessment of venous congestion","volume":"28","author":"Argaiz","year":"2021","journal-title":"Adv Chronic Kidney Dis"},{"key":"R46-20250729","doi-asserted-by":"crossref","first-page":"746","DOI":"10.5005\/jp-journals-10071-23582","article-title":"VEXUS-the third eye for the intensivist?","volume":"24","author":"Gupta","year":"2020","journal-title":"Indian J Crit Care Med"},{"key":"R47-20250729","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1186\/s13054-023-04471-0","article-title":"Correlation between the VExUS score and right atrial pressure: a pilot prospective observational study","volume":"27","author":"Longino","year":"2023","journal-title":"Crit Care"},{"key":"R48-20250729","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1016\/j.chest.2023.09.029","article-title":"Prospective evaluation of venous excess ultrasound (VExUS) for estimation of venous congestion","volume":"165","author":"Longino","year":"2024","journal-title":"Chest"},{"key":"R49-20250729","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1186\/s13054-023-04524-4","article-title":"Prevalence of systemic venous congestion assessed by Venous Excess Ultrasound Grading System (VExUS) and association with acute kidney injury in a general ICU cohort: a prospective multicentric study","volume":"27","author":"Andrei","year":"2023","journal-title":"Crit Care"},{"key":"R50-20250729","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1002\/jum.16057","article-title":"Feasibility and utility of the venous excess ultrasound score to detect and grade central venous pressure elevation in critically ill children","volume":"42","author":"Menendez-Suso","year":"2023","journal-title":"J Ultrasound Med"},{"key":"R51-20250729","first-page":"e20545","article-title":"Perioperative venous excess ultrasound score (VExUS) to guide decongestion in a dilated cardiomyopathy patient presenting for urgent surgery","volume":"13","author":"Singh","year":"2021","journal-title":"Cureus"},{"key":"R52-20250729","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1186\/s13089-021-00232-8","article-title":"Clinical applications of the venous excess ultrasound (VExUS) score: conceptual review and case series","volume":"13","author":"Rola","year":"2021","journal-title":"Ultrasound J"},{"key":"R53-20250729","doi-asserted-by":"crossref","first-page":"783","DOI":"10.5005\/jp-journals-10071-23570","article-title":"Combination of inferior vena cava diameter, hepatic venous flow, and portal vein pulsatility index: venous excess ultrasound score (VEXUS Score) in predicting acute kidney injury in patients with cardiorenal syndrome: a prospective cohort study","volume":"24","author":"Bhardwaj","year":"2020","journal-title":"Indian J Crit Care Med"},{"key":"R54-20250729","doi-asserted-by":"crossref","first-page":"2547","DOI":"10.1002\/jum.16288","article-title":"VExUS Score in the management of patients with acute kidney injury in the intensive care unit: AKIVEX Study","volume":"42","author":"Rihl","year":"2023","journal-title":"J Ultrasound Med"},{"key":"R55-20250729","doi-asserted-by":"crossref","first-page":"154441","DOI":"10.1016\/j.jcrc.2023.154441","article-title":"Comparison of various surrogate markers for venous congestion in predicting acute kidney injury following cardiac surgery: a cohort study","volume":"79","author":"Li","year":"2023","journal-title":"J Crit Care"},{"key":"R56-20250729","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1186\/s13054-022-04180-0","article-title":"Doppler study of portal vein and renal venous velocity predict the appropriate fluid response to diuretic in ICU: a prospective observational echocardiographic evaluation","volume":"26","author":"Guinot","year":"2022","journal-title":"Crit Care"},{"key":"R57-20250729","doi-asserted-by":"crossref","first-page":"93","DOI":"10.24908\/pocus.v8i1.16188","article-title":"Evaluation of congestion levels in septic patients admitted to critical care units with a combined Venous Excess-Lung Ultrasound Score (VExLUS): a research protocol","volume":"8","author":"Romano","year":"2023","journal-title":"POCUS J"},{"key":"R58-20250729","doi-asserted-by":"crossref","first-page":"e074843","DOI":"10.1136\/bmjopen-2023-074843","article-title":"Doppler identified venous congestion in septic shock: protocol for an international, multicentre prospective cohort study (Andromeda-VEXUS)","volume":"13","author":"Prager","year":"2023","journal-title":"BMJ Open"}],"container-title":["Current Opinion in Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MCC.0000000000001155","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,29]],"date-time":"2025-07-29T20:05:23Z","timestamp":1753819523000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MCC.0000000000001155"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,28]]},"references-count":58,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/mcc.0000000000001155","relation":{},"ISSN":["1070-5295","1531-7072"],"issn-type":[{"value":"1070-5295","type":"print"},{"value":"1531-7072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,28]]}}}