{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T18:48:06Z","timestamp":1790102886933,"version":"4.0.1"},"reference-count":69,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>After more than 50\u200ayears from its invention, the intra-aortic balloon pump (IABP) is still one of the most widely used mechanical circulatory support devices to treat cardiogenic shock (CS). This review aims to describe the role of IABP in current clinical practice.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>In recent years the better understanding of the variable hemodynamic profiles that characterize the CS condition has led to a reappraisal of the IABP role in select CS phenotypes. Combining a \u201cmechanical\u201d afterload reduction with an increase in mean arterial pressure, this device appears particularly suited to treat acute decompensated heart failure-CS and the mechanical complications of an acute myocardial infarction, as these conditions would greatly benefit from systemic afterload reduction. Notwithstanding the negative results of IABP support for acute myocardial infarction-related CS, this document reviews other potential established and emerging settings of application.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>In this scoping review, we discuss the IABP design and hemodynamic effects, with a pathophysiology-oriented outlook to its clinical use. Different options for IABP device insertion, potential complications, and optimal device synchronization with cardiac cycle are also summarized with the aim to provide an updated, pragmatic guide to critical care physicians using these devices.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mcc.0000000000001283","type":"journal-article","created":{"date-parts":[[2025,6,16]],"date-time":"2025-06-16T10:03:03Z","timestamp":1750068183000},"page":"451-463","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["The intra-aortic balloon pump: a modern practical perspective"],"prefix":"10.1097","volume":"31","author":[{"given":"Luca","family":"Baldetti","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Cianfanelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Mara","family":"Scandroglio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,5,16]]},"reference":[{"key":"R1-20250819","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1016\/0003-4975(90)90220-Z","article-title":"Origins of intraaortic balloon pumping","volume":"50","author":"Kantrowitz","year":"1990","journal-title":"Ann Thorac Surg"},{"key":"R2-20250819","doi-asserted-by":"crossref","first-page":"e008527","DOI":"10.1161\/CIRCHEARTFAILURE.121.008527","article-title":"Intra-aortic balloon pumping in acute decompensated heart failure with hypoperfusion: from pathophysiology to clinical practice","volume":"14","author":"Baldetti","year":"2021","journal-title":"Circ Heart Fail"},{"key":"R3-20250819","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1056\/NEJMoa1208410","article-title":"Intraaortic balloon support for myocardial infarction with cardiogenic shock","volume":"367","author":"Thiele","year":"2012","journal-title":"N Engl J Med"},{"key":"R4-20250819","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1186\/s13019-016-0513-0","article-title":"IABP: history-evolution-pathophysiology-indications: what we need to know","volume":"11","author":"Parissis","year":"2016","journal-title":"J Cardiothorac Surg"},{"key":"R5-20250819","first-page":"101337","article-title":"The intra-aortic balloon pump: a focused review of physiology, transport logistics, mechanics, and complications","volume":"3","author":"Gillespie","year":"2024","journal-title":"J Soc Cardiovasc Angiogr Interv"},{"key":"R6-20250819","first-page":"1","article-title":"The intra-aortic balloon pump","volume":"2021","author":"Gajanan","year":"2021","journal-title":"J Vis Exp"},{"key":"R7-20250819","doi-asserted-by":"crossref","first-page":"323","DOI":"10.4037\/ajcc2011542","article-title":"Intra-aortic balloon pump timing: review of evidence supporting current practice","volume":"20","author":"Hanlon-Pena","year":"2011","journal-title":"Am J Crit Care"},{"key":"R8-20250819","first-page":"E63","article-title":"A single center tertiary care experience utilizing the large volume mega 50cc intra-aortic balloon counterpulsation in contemporary clinical practice","volume":"90","author":"Visveswaran","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"key":"R9-20250819","first-page":"703","article-title":"Differential responses to larger volume intra-aortic balloon counterpulsation: hemodynamic and clinical outcomes","volume":"92","author":"Baran","year":"2018","journal-title":"Catheter Cardiovasc Interv"},{"key":"R10-20250819","doi-asserted-by":"crossref","first-page":"1456","DOI":"10.1016\/S0735-1097(01)01553-4","article-title":"The current practice of intra-aortic balloon counterpulsation: results from the Benchmark Registry","volume":"38","author":"Ferguson","year":"2001","journal-title":"J Am Coll Cardiol"},{"key":"R11-20250819","first-page":"1976","article-title":"Bedside intra-aortic balloon pump insertion in cardiac intensive care unit: a single-center experience","volume":"99","author":"Baldetti","year":"2022","journal-title":"Catheter Cardiovasc Interv"},{"key":"R12-20250819","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1016\/0003-4975(89)90694-2","article-title":"Axillary artery insertion of an intraaortic balloon pump","volume":"48","author":"McBride","year":"1989","journal-title":"Ann Thorac Surg"},{"key":"R13-20250819","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.jchf.2020.01.011","article-title":"Percutaneous left axillary artery placement of intra-aortic balloon pump in advanced heart failure patients","volume":"8","author":"Bhimaraj","year":"2020","journal-title":"JACC Heart Fail"},{"key":"R14-20250819","doi-asserted-by":"crossref","first-page":"e147","DOI":"10.1161\/CIRCULATIONAHA.111.032235","article-title":"Femoral arterial access and closure","volume":"124","author":"Bangalore","year":"2011","journal-title":"Circulation"},{"key":"R15-20250819","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.amjcard.2022.11.033","article-title":"Sheathless versus sheathed intra-aortic balloon pump implantation in patients undergoing cardiac surgery","volume":"189","author":"Heuts","year":"2023","journal-title":"Am J Cardiol"},{"key":"R16-20250819","doi-asserted-by":"crossref","first-page":"e210120","DOI":"10.1148\/ryct.210120","article-title":"Radiology of intra-aortic balloon pump catheters","volume":"4","author":"Rhodes","year":"2022","journal-title":"Radiol Cardiothorac Imaging"},{"key":"R17-20250819","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/j.rcl.2004.03.006","article-title":"Postoperative cardiopulmonary thoracic imaging","volume":"42","author":"Attili","year":"2004","journal-title":"Radiol Clin North Am"},{"key":"R18-20250819","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1213\/ANE.0b013e3182140b9a","article-title":"Positioning an intraaortic balloon pump using intraoperative transesophageal echocardiogram guidance","volume":"113","author":"Klopman","year":"2011","journal-title":"Anesth Analg"},{"key":"R19-20250819","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1007\/s40119-019-00152-8","article-title":"Complications of temporary percutaneous mechanical circulatory support for cardiogenic shock: an appraisal of contemporary literature","volume":"8","author":"Subramaniam","year":"2019","journal-title":"Cardiol Ther"},{"key":"R20-20250819","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1177\/0267659117727825","article-title":"Vascular complications following intra-aortic balloon pump implantation: an updated review","volume":"33","author":"de Jong","year":"2018","journal-title":"Perfusion"},{"key":"R21-20250819","first-page":"621","article-title":"Management of intra-aortic balloon pump entrapment: a case report and review of the literature","volume":"39","author":"Fitzmaurice","year":"2012","journal-title":"Tex Heart Inst J"},{"key":"R22-20250819","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1016\/S0003-4975(10)64737-6","article-title":"Arterial helium embolism from a ruptured intraaortic balloon","volume":"46","author":"Frederiksen","year":"1988","journal-title":"Ann Thorac Surg"},{"key":"R23-20250819","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/S0196-0644(00)70086-2","article-title":"Cerebral arterial gas embolism by helium: an unusual case successfully treated with hyperbaric oxygen and lidocaine","volume":"35","author":"Mitchell","year":"2000","journal-title":"Ann Emerg Med"},{"key":"R24-20250819","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1016\/j.athoracsur.2004.07.073","article-title":"Beat-to-beat effects of intraaortic balloon pump timing on left ventricular performance in patients with low ejection fraction","volume":"79","author":"Schreuder","year":"2005","journal-title":"Ann Thorac Surg"},{"key":"R25-20250819","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1016\/S0002-8703(99)70373-X","article-title":"Hemodynamic effects of new intra-aortic balloon counterpulsation timing methods in patients: a multicenter evaluation","volume":"137","author":"Kern","year":"1999","journal-title":"Am Heart J"},{"key":"R26-20250819","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.healun.2022.12.007","article-title":"Effects of intra-aortic balloon pump delayed deflation timing on carotid blood flow and cardiac mechanics: an ultrasound and haemodynamic study","volume":"42","author":"Boccellino","year":"2023","journal-title":"J Heart Lung Transplant"},{"key":"R27-20250819","doi-asserted-by":"crossref","first-page":"835","DOI":"10.4244\/EIJV11I7A168","article-title":"The pulsecath iVAC 2L left ventricular assist device: conversion to a percutaneous transfemoral approach","volume":"11","author":"Van Mieghem","year":"2015","journal-title":"EuroIntervention"},{"key":"R28-20250819","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.4244\/EIJ-D-16-00371","article-title":"Pulsatile iVAC 2L circulatory support in high-risk percutaneous coronary intervention","volume":"12","author":"Uil","year":"2017","journal-title":"EuroIntervention"},{"key":"R29-20250819","doi-asserted-by":"crossref","first-page":"563448","DOI":"10.3389\/fcvm.2020.563448","article-title":"Case report first-in-man method description: left ventricular unloading with iVAC2L during veno-arterial extracorporeal membrane oxygenation: from veno-arterial extracorporeal membrane oxygenation to ECMELLA to EC-iVAC\u00ae","volume":"7","author":"Tsch\u00f6pe","year":"2020","journal-title":"Front Cardiovasc Med"},{"key":"R30-20250819","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1161\/CIRCULATIONAHA.118.038201","article-title":"Intraaortic balloon pump in cardiogenic shock complicating acute myocardial infarction","volume":"139","author":"Thiele","year":"2019","journal-title":"Circulation"},{"key":"R31-20250819","doi-asserted-by":"crossref","first-page":"e771","DOI":"10.1161\/CIR.0000000000001328","article-title":"2025 ACC\/AHA\/ACEP\/NAEMSP\/SCAI guideline for the management of patients with acute coronary syndromes: a report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"151","author":"Rao","year":"2025","journal-title":"Circulation"},{"key":"R32-20250819","doi-asserted-by":"crossref","first-page":"E009279","DOI":"10.1161\/CIRCHEARTFAILURE.121.009279","article-title":"Cardiogenic shock from heart failure versus acute myocardial infarction: clinical characteristics, hospital course, and 1-year outcomes","volume":"15","author":"Sinha","year":"2022","journal-title":"Circ Heart Fail"},{"key":"R33-20250819","doi-asserted-by":"crossref","first-page":"E007099","DOI":"10.1161\/CIRCHEARTFAILURE.120.007099","article-title":"Invasive hemodynamic assessment and classification of in-hospital mortality risk among patients with cardiogenic shock","volume":"13","author":"Thayer","year":"2020","journal-title":"Circ Heart Fail"},{"key":"R34-20250819","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/0033-0620(76)90021-9","article-title":"Afterload mismatch and preload reserve: a conceptual framework for the analysis of ventricular function","volume":"18","author":"Ross","year":"1976","journal-title":"Prog Cardiovasc Dis"},{"key":"R35-20250819","doi-asserted-by":"crossref","first-page":"3384","DOI":"10.3390\/jcm9113384","article-title":"Hemodynamic profiles of cardiogenic shock depending on their etiology","volume":"9","author":"Gaubert","year":"2020","journal-title":"J Clin Med"},{"key":"R36-20250819","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1097\/SHK.0000000000001052","article-title":"Cardiogenic shock due to end-stage heart failure and acute myocardial infarction","volume":"50","author":"Lim","year":"2018","journal-title":"Shock"},{"key":"R37-20250819","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1056\/NEJM199908263410901","article-title":"Early revascularization in acute myocardial infarction complicated by cardiogenic shock","volume":"341","author":"Hochman","year":"1999","journal-title":"N Engl J Med"},{"key":"R38-20250819","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1056\/NEJMoa2312572","article-title":"Microaxial flow pump or standard care in infarct-related cardiogenic shock","volume":"390","author":"M\u00f8ller","year":"2024","journal-title":"N Engl J Med"},{"key":"R39-20250819","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1016\/j.healun.2018.03.011","article-title":"Clinical and hemodynamic effects of intra-aortic balloon pump therapy in chronic heart failure patients with cardiogenic shock","volume":"37","author":"Fried","year":"2018","journal-title":"J Heart Lung Transplant"},{"key":"R40-20250819","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.ejim.2023.11.002","article-title":"Prognostic role of mitral regurgitation in patients with advanced heart failure","volume":"122","author":"Pagnesi","year":"2024","journal-title":"Eur J Intern Med"},{"key":"R41-20250819","doi-asserted-by":"crossref","first-page":"E275","DOI":"10.25270\/jic\/20.00473","article-title":"Predictors of hemodynamic response to intra-aortic balloon pump therapy in patients with acute decompensated heart failure and cardiogenic shock","volume":"33","author":"Huang","year":"2021","journal-title":"J Invasive Cardiol"},{"key":"R42-20250819","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1056\/NEJM197305102881901","article-title":"Intra-aortic balloon counterpulsation in cardiogenic shock","volume":"288","author":"Scheidt","year":"1973","journal-title":"N Engl J Med"},{"key":"R43-20250819","doi-asserted-by":"crossref","first-page":"1947","DOI":"10.1016\/j.amjcard.2019.09.016","article-title":"Comparison of the hemodynamic response to intra-aortic balloon counterpulsation in patients with cardiogenic shock resulting from acute myocardial infarction versus acute decompensated heart failure","volume":"124","author":"Malick","year":"2019","journal-title":"Am J Cardiol"},{"key":"R44-20250819","doi-asserted-by":"crossref","first-page":"E007924","DOI":"10.1161\/CIRCHEARTFAILURE.120.007924","article-title":"Clinical outcomes associated with acute mechanical circulatory support utilization in heart failure related cardiogenic shock","volume":"14","author":"Hernandez-Montfort","year":"2021","journal-title":"Circ Heart Fail"},{"key":"R45-20250819","doi-asserted-by":"crossref","first-page":"586","DOI":"10.4244\/EIJ-D-19-00254","article-title":"Primary intra-aortic balloon support versus inotropes for decompensated heart failure and low output: a randomised trial","volume":"15","author":"den Uil","year":"2019","journal-title":"EuroIntervention"},{"key":"R46-20250819","doi-asserted-by":"crossref","first-page":"E006666","DOI":"10.1161\/CIRCHEARTFAILURE.119.006666","article-title":"Clinical outcomes and quality of life with an ambulatory counterpulsation pump in advanced heart failure patients: results of the multicenter feasibility trial","volume":"13","author":"Uriel","year":"2020","journal-title":"Circ Heart Fail"},{"key":"R47-20250819","doi-asserted-by":"crossref","first-page":"E16","DOI":"10.1161\/CIR.0000000000000985","article-title":"Mechanical complications of acute myocardial infarction: a scientific statement from the American Heart Association","volume":"144","author":"Damluji","year":"2021","journal-title":"Circulation"},{"key":"R48-20250819","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1016\/j.jcin.2021.02.046","article-title":"Mechanical circulatory support as a bridge to definitive treatment in post-infarction ventricular septal rupture","volume":"14","author":"Ronco","year":"2021","journal-title":"JACC Cardiovasc Interv"},{"key":"R49-20250819","doi-asserted-by":"crossref","first-page":"1886","DOI":"10.1016\/j.jacc.2024.01.041","article-title":"Ventricular septal rupture after myocardial infarction: JACC focus seminar 3\/5","volume":"83","author":"Cubeddu","year":"2024","journal-title":"J Am Coll Cardiol"},{"key":"R50-20250819","doi-asserted-by":"crossref","first-page":"1799","DOI":"10.1016\/j.jacc.2023.09.840","article-title":"Management of severe mitral regurgitation in patients with acute myocardial infarction: JACC focus seminar 2\/5","volume":"83","author":"Est\u00e9vez-Loureiro","year":"2024","journal-title":"J Am Coll Cardiol"},{"key":"R51-20250819","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.1016\/j.jcin.2019.04.039","article-title":"Temporal trends and outcomes of mechanical complications in patients with acute myocardial infarction","volume":"12","author":"Elbadawi","year":"2019","journal-title":"JACC Cardiovasc Interv"},{"issue":"(Suppl A)","key":"R52-20250819","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1016\/S0735-1097(00)00878-0","article-title":"Outcome and profile of ventricular septal rupture with cardiogenic shock after myocardial infarction: a report from the SHOCK Trial Registry. SHould we emergently revascularize Occluded Coronaries in cardiogenic shocK?","volume":"36","author":"Menon","year":"2000","journal-title":"J Am Coll Cardiol"},{"key":"R53-20250819","doi-asserted-by":"crossref","first-page":"2229","DOI":"10.1253\/circj.CJ-19-0593","article-title":"Surgical repair of post-infarction ventricular septal defect \u2013 findings From a Japanese National Database","volume":"83","author":"Sakaguchi","year":"2019","journal-title":"Circ J"},{"key":"R54-20250819","doi-asserted-by":"crossref","first-page":"e005981","DOI":"10.1161\/CIRCHEARTFAILURE.119.005981","article-title":"Hemodynamic effects of mechanical circulatory support devices in ventricular septal defect","volume":"12","author":"Pahuja","year":"2019","journal-title":"Circ Heart Fail"},{"key":"R55-20250819","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/S0002-9149(03)00665-9","article-title":"Short- and long-term hemodynamic effects of intra-aortic balloon support in ventricular septal defect complicating acute myocardial infarction","volume":"92","author":"Thiele","year":"2003","journal-title":"Am J Cardiol"},{"key":"R56-20250819","doi-asserted-by":"crossref","first-page":"252","DOI":"10.21037\/acs-2021-ami-15","article-title":"Surgical treatment of postinfarction papillary muscle rupture: systematic review and meta-analysis","volume":"11","author":"Massimi","year":"2022","journal-title":"Ann Cardiothorac Surg"},{"key":"R57-20250819","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1001\/jama.2011.1280","article-title":"Intra-aortic balloon counterpulsation and infarct size in patients with acute anterior myocardial infarction without shock: the CRISP AMI randomized trial","volume":"306","author":"Patel","year":"2011","journal-title":"JAMA"},{"key":"R58-20250819","doi-asserted-by":"crossref","first-page":"286","DOI":"10.4244\/EIJY14M09_10","article-title":"Intra-aortic balloon counterpulsation reduces mortality in large anterior myocardial infarction complicated by persistent ischaemia: a CRISP-AMI substudy","volume":"11","author":"Van Nunen","year":"2015","journal-title":"EuroIntervention"},{"key":"R59-20250819","first-page":"128","article-title":"Intra-aortic balloon pump counterpulsation in extensive myocardial infarction with persistent ischemia: The SEMPER FI pilot study","volume":"95","author":"van Nunen","year":"2020","journal-title":"Catheter Cardiovasc Interv"},{"key":"R60-20250819","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1093\/ejcts\/ezv258","article-title":"Preoperative intra-aortic counterpulsation in high-risk patients undergoing cardiac surgery: a meta-analysis of randomized controlled trials","volume":"49","author":"Pilarczyk","year":"2016","journal-title":"Eur J Cardiothorac Surg"},{"key":"R61-20250819","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1111\/jocs.13114","article-title":"Preoperative intra-aortic balloon pump use in high-risk patients prior to coronary artery bypass graft surgery decreases the risk for morbidity and mortality \u2013 a meta-analysis of 9,212 patients","volume":"32","author":"Deppe","year":"2017","journal-title":"J Card Surg"},{"key":"R62-20250819","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1186\/s13054-014-0728-1","article-title":"Preoperative intra-aortic balloon pump to reduce mortality in coronary artery bypass graft: a meta-analysis of randomized controlled trials","volume":"19","author":"Zangrillo","year":"2015","journal-title":"Crit Care"},{"key":"R63-20250819","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.jtcvs.2009.09.033","article-title":"Influence of timing of intraaortic balloon placement in cardiac surgical patients","volume":"140","author":"Lavana","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R64-20250819","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1002\/ehf2.14717","article-title":"Left ventricular unloading and venting in veno-arterial extracorporeal membrane oxygenation: the importance of cardiogenic shock aetiology in guiding treatment strategies","volume":"11","author":"Baldetti","year":"2024","journal-title":"ESC Heart Fail"},{"key":"R65-20250819","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.ijcard.2020.02.004","article-title":"Strategies of left ventricular unloading during VA-ECMO support: a network meta-analysis","volume":"312","author":"Baldetti","year":"2020","journal-title":"Int J Cardiol"},{"key":"R66-20250819","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1016\/j.amjcard.2023.07.183","article-title":"Trends in the incidence of cardiogenic shock, and utilization of mechanical circulatory support in myocarditis: insights from the national inpatient sample 2016 to 2019","volume":"205","author":"Steitieh","year":"2023","journal-title":"Am J Cardiol"},{"key":"R67-20250819","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1016\/S0735-1097(17)34249-3","article-title":"Outcomes of intra-aortic balloon pump use in myocarditis complicated by cardiogenic shock","volume":"69","author":"Ogunbayo","year":"2017","journal-title":"J Am Coll Cardiol"},{"issue":"(1 Pt A)","key":"R68-20250819","doi-asserted-by":"crossref","first-page":"102020","DOI":"10.1016\/j.cpcardiol.2023.102020","article-title":"Contemporary national trends of mechanical circulatory support among myocarditis hospitalizations before the pandemic: a national in-patient database (2005-2019) study","volume":"49","author":"Shah","year":"2024","journal-title":"Curr Probl Cardiol"},{"key":"R69-20250819","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.jacc.2016.10.022","article-title":"Percutaneous mechanical circulatory support versus intra-aortic balloon pump in cardiogenic shock after acute myocardial infarction","volume":"69","author":"Ouweneel","year":"2017","journal-title":"J Am Coll Cardiol"}],"container-title":["Current Opinion in Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MCC.0000000000001283","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,19]],"date-time":"2025-08-19T18:01:09Z","timestamp":1755626469000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MCC.0000000000001283"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,16]]},"references-count":69,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/mcc.0000000000001283","relation":{},"ISSN":["1070-5295","1531-7072"],"issn-type":[{"value":"1070-5295","type":"print"},{"value":"1531-7072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,16]]}}}