{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:17:18Z","timestamp":1786119438840,"version":"build-2736575974"},"reference-count":48,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Goals:<\/jats:title>\n                    <jats:p>To explore dynamic contrast-enhanced ultrasound (CEUS) parameters in predicting hepatic vein pressure gradient (HVPG) for patients with liver cirrhosis (LC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Noninvasive diagnosis of HVPG remains a challenge.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study:<\/jats:title>\n                    <jats:p>This prospective study included patients with LC undergoing hepatic vein catheterization and pressure measurement at the hospital from May 2021 to January 2023. The CEUS images (Mindray Resona R9, 1-6-MHz probe frequency; mechanical index=0.08; image depth=10\u00a0cm; focus at the lowest point of the diaphragm; dynamic range=70\u00a0dB; optimal gain; single SonoVue bolus injection) were taken for 60 seconds after injection and analyzed using VueBox. HVPG (ie, the gold standard for portal hypertension) was measured routinely by catheterization.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Fifty patients with LC were included in the study. The rise time (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      =0.6,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.01), the fall time (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      =0.7,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.01), the peak time (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      =0.6,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.01), wash-in area under the curve (AUC) (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      =0.5,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.01), the wash-out phase AUC (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      =0.4,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.01) and wash-in and wash-out phase AUC (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      =0.4,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.01) of the dynamic spleen CEUS were positively correlated with HVPG. The optimal fall time cutoff levels to predict HVPG \u226510\u00a0mm\u00a0Hg and \u226512\u00a0mm\u00a0Hg were 27.0 and 36.4 seconds, with the AUC being 0.958 and 0.941, respectively. The optimal area under the wash-in area cutoff level to predict HVPG \u226510\u00a0mm\u00a0Hg and \u226512\u00a0mm\u00a0Hg was 1,658,967.38 (a.u) and 4,244,015.90 (a.u), with the AUC being 0.865 and 0.877, respectively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The fall time and wash-in AUC obtained by dynamic CEUS may help diagnose HVPG in patients with LC without requiring invasive hepatic vein catheterization.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/mcg.0000000000002136","type":"journal-article","created":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T10:18:10Z","timestamp":1738145890000},"page":"182-189","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Value of Spleen Dynamic Contrast-enhanced Ultrasound Parameters in Predicting Hepatic Vein Pressure Gradient for Patients With Liver Cirrhosis"],"prefix":"10.1097","volume":"60","author":[{"given":"Tie","family":"Zhou","sequence":"first","affiliation":[{"name":"The Third Central Hospital of Tianjin, Hedong District"},{"name":"Tianjin Key Laboratory of Extracorporeal Life Support for Critical Diseases"},{"name":"Artificial Cell Engineering Technology Research Center"},{"name":"Tianjin Institute of Hepatobiliary Disease, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Zhou","sequence":"additional","affiliation":[{"name":"The Third Central Hospital of Tianjin, Hedong District"},{"name":"Tianjin Key Laboratory of Extracorporeal Life Support for Critical Diseases"},{"name":"Artificial Cell Engineering Technology Research Center"},{"name":"Tianjin Institute of Hepatobiliary Disease, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Zhao","sequence":"additional","affiliation":[{"name":"The Third Central Hospital of Tianjin, Hedong District"},{"name":"Tianjin Key Laboratory of Extracorporeal Life Support for Critical Diseases"},{"name":"Artificial Cell Engineering Technology Research Center"},{"name":"Tianjin Institute of Hepatobiliary Disease, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanmin","family":"Kan","sequence":"additional","affiliation":[{"name":"The Third Central Hospital of Tianjin, Hedong District"},{"name":"Tianjin Key Laboratory of Extracorporeal Life Support for Critical Diseases"},{"name":"Artificial Cell Engineering Technology Research Center"},{"name":"Tianjin Institute of Hepatobiliary Disease, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianmin","family":"Ding","sequence":"additional","affiliation":[{"name":"The Third Central Hospital of Tianjin, Hedong District"},{"name":"Tianjin Key Laboratory of Extracorporeal Life Support for Critical Diseases"},{"name":"Artificial Cell Engineering Technology Research Center"},{"name":"Tianjin Institute of Hepatobiliary Disease, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng","family":"Sun","sequence":"additional","affiliation":[{"name":"The Third Central Hospital of Tianjin, Hedong District"},{"name":"Tianjin Key Laboratory of Extracorporeal Life Support for Critical Diseases"},{"name":"Artificial Cell Engineering Technology Research Center"},{"name":"Tianjin Institute of Hepatobiliary Disease, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiang","family":"Jing","sequence":"additional","affiliation":[{"name":"The Third Central Hospital of Tianjin, Hedong District"},{"name":"Tianjin Key Laboratory of Extracorporeal Life Support for Critical Diseases"},{"name":"Artificial Cell Engineering Technology Research Center"},{"name":"Tianjin Institute of Hepatobiliary Disease, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,2]]},"reference":[{"key":"R1-20260105","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1016\/j.jceh.2022.04.021","article-title":"Overview of complications in cirrhosis","volume":"12","author":"Premkumar","year":"2022","journal-title":"J Clin Exp Hepatol"},{"key":"R2-20260105","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1016\/j.jhep.2021.12.022","article-title":"Baveno VII - Renewing consensus in portal hypertension","volume":"76","author":"de Franchis","year":"2022","journal-title":"J Hepatol"},{"key":"R3-20260105","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1136\/gutjnl-2020-321299","article-title":"Guidelines on the use of liver biopsy in clinical practice from the British Society of Gastroenterology, the Royal College of Radiologists and the Royal College of Pathology","volume":"69","author":"Neuberger","year":"2020","journal-title":"Gut"},{"key":"R4-20260105","doi-asserted-by":"crossref","first-page":"464","DOI":"10.5009\/gnl16078","article-title":"Ultrasonography for noninvasive assessment of portal hypertension","volume":"11","author":"Maruyama","year":"2017","journal-title":"Gut Liver"},{"key":"R5-20260105","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1046\/j.1440-1746.2003.02992.x","article-title":"Comparison of Doppler ultrasonography and the hepatic venous pressure gradient in assessing portal hypertension in liver cirrhosis","volume":"18","author":"Choi","year":"2003","journal-title":"J Gastroenterol Hepatol"},{"key":"R6-20260105","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1007\/s00535-010-0360-z","article-title":"Prognostic value of a single HVPG measurement and Doppler-ultrasound evaluation in patients with cirrhosis and portal hypertension","volume":"46","author":"Berzigotti","year":"2011","journal-title":"J Gastroenterol"},{"key":"R7-20260105","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1016\/j.jhep.2016.07.021","article-title":"Noninvasive assessment of portal hypertension using quantitative magnetic resonance imaging","volume":"65","author":"Palaniyappan","year":"2016","journal-title":"J Hepatol"},{"key":"R8-20260105","first-page":"e18243","article-title":"Contrast-enhanced ultrasonography: review and applications","volume":"13","author":"Ajmal","year":"2021","journal-title":"Cureus"},{"key":"R9-20260105","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.clinimag.2019.12.013","article-title":"Contrast enhanced ultrasound: a review of radiology applications","volume":"60","author":"Erlichman","year":"2020","journal-title":"Clin Imaging"},{"key":"R10-20260105","doi-asserted-by":"crossref","first-page":"1057045","DOI":"10.3389\/fmed.2022.1057045","article-title":"Contrast-enhanced ultrasonography for the management of portal hypertension in cirrhosis","volume":"9","author":"Maruyama","year":"2022","journal-title":"Front Med (Lausanne)"},{"key":"R11-20260105","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1002\/hep.25752","article-title":"Hepatic vein arrival time as assessed by contrast-enhanced ultrasonography is useful for the assessment of portal hypertension in compensated cirrhosis","volume":"56","author":"Kim","year":"2012","journal-title":"Hepatology"},{"key":"R12-20260105","doi-asserted-by":"crossref","first-page":"e0121601","DOI":"10.1371\/journal.pone.0121601","article-title":"Severe portal hypertension in cirrhosis: evaluation of perfusion parameters with contrast-enhanced ultrasonography","volume":"10","author":"Jeong","year":"2015","journal-title":"PLoS One"},{"key":"R13-20260105","doi-asserted-by":"crossref","first-page":"583","DOI":"10.21037\/atm.2019.09.22","article-title":"Portal pressure monitoring\u2014state-of-the-art and future perspective","volume":"7","author":"Xu","year":"2019","journal-title":"Ann Transl Med"},{"key":"R14-20260105","doi-asserted-by":"crossref","first-page":"e938998","DOI":"10.12659\/MSM.938998","article-title":"Splenic artery steal syndrome in patients with liver cirrhosis: a retrospective clinical study","volume":"29","author":"Mao","year":"2023","journal-title":"Med Sci Monit"},{"key":"R15-20260105","first-page":"613","article-title":"Comparative aspects of splenic microcirculatory pathways in mammals: the region bordering the white pulp","volume":"7","author":"Schmidt","year":"1993","journal-title":"Scanning Microsc"},{"key":"R16-20260105","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1080\/01926230600867743","article-title":"Normal structure, function, and histology of the spleen","volume":"34","author":"Cesta","year":"2006","journal-title":"Toxicol Pathol"},{"key":"R18-20260105","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1007\/s00330-014-3476-3","article-title":"Impact of splenic circulation: noninvasive microbubble-based assessment of portal hemodynamics","volume":"25","author":"Shimada","year":"2015","journal-title":"Eur Radiol"},{"key":"R19-20260105","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1007\/s12072-022-10367-y","article-title":"Standardized HVPG measurement: call for action","volume":"16","author":"Li","year":"2022","journal-title":"Hepatol Int"},{"key":"R20-20260105","doi-asserted-by":"crossref","first-page":"6","DOI":"10.3350\/cmh.2014.20.1.6","article-title":"Hepatic venous pressure gradient: clinical use in chronic liver disease","volume":"20","author":"Suk","year":"2014","journal-title":"Clin Mol Hepatol"},{"key":"R21-20260105","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1002\/lt.21227","article-title":"Hepatic venous pressure gradient to assess fibrosis and its progression after liver transplantation for HCV cirrhosis","volume":"13","author":"Samonakis","year":"2007","journal-title":"Liver Transpl"},{"key":"R22-20260105","doi-asserted-by":"crossref","first-page":"20210061","DOI":"10.1259\/bjr.20210061","article-title":"Hepatic venous-portal gradient (HVPG) measurement: pearls and pitfalls","volume":"94","author":"Lu","year":"2021","journal-title":"Br J Radiol"},{"key":"R23-20260105","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1002\/cld.1031","article-title":"Hepatic venous pressure gradient","volume":"17","author":"Bochnakova","year":"2021","journal-title":"Clin Liver Dis (Hoboken)"},{"key":"R24-20260105","doi-asserted-by":"crossref","first-page":"3313","DOI":"10.1007\/s10620-021-07168-y","article-title":"Network meta-analysis: noninvasive imaging modalities for identifying clinically significant portal hypertension","volume":"67","author":"Hai","year":"2022","journal-title":"Dig Dis Sci"},{"key":"R25-20260105","doi-asserted-by":"crossref","first-page":"4202091","DOI":"10.1155\/2018\/4202091","article-title":"Noninvasive assessment of portal hypertension in advanced chronic liver disease: an update","volume":"2018","author":"Ravaioli","year":"2018","journal-title":"Gastroenterol Res Pract"},{"key":"R26-20260105","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1002\/jmri.26716","article-title":"Liver fibrosis imaging: a clinical review of ultrasound and magnetic resonance elastography","volume":"51","author":"Zhang","year":"2020","journal-title":"J Magn Reson Imaging"},{"key":"R27-20260105","first-page":"8","article-title":"Ultrasound in portal hypertension\u2014part 2\u2014and EFSUMB recommendations for the performance and reporting of ultrasound examinations in portal hypertension","volume":"33","author":"Berzigotti","year":"2012","journal-title":"Ultraschall Med"},{"key":"R28-20260105","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1055\/s-0031-1281856","article-title":"Ultrasound in portal hypertension\u2014part 1","volume":"32","author":"Berzigotti","year":"2011","journal-title":"Ultraschall Med"},{"key":"R29-20260105","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1097\/00042737-200204000-00008","article-title":"Doppler measurements: a surrogate marker of liver fibrosis?","volume":"14","author":"Bernatik","year":"2002","journal-title":"Eur J Gastroenterol Hepatol"},{"key":"R30-20260105","doi-asserted-by":"crossref","first-page":"1848","DOI":"10.2214\/ajr.184.6.01841848","article-title":"Can Doppler sonography grade the severity of hepatitis C-related liver disease?","volume":"184","author":"Lim","year":"2005","journal-title":"AJR Am J Roentgenol"},{"key":"R31-20260105","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1148\/radiol.13121769","article-title":"Chronic liver disease: noninvasive subharmonic aided pressure estimation of hepatic venous pressure gradient","volume":"268","author":"Eisenbrey","year":"2013","journal-title":"Radiology"},{"key":"R32-20260105","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1002\/poh2.45","article-title":"Subharmonic aided pressure estimation in portal hypertension: a noninvasive ultrasound-based technique to assess portal pressure gradient","volume":"2","author":"Huang","year":"2023","journal-title":"Portal Hypertens Cirrh"},{"key":"R33-20260105","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1055\/s-0032-1313026","article-title":"An EFSUMB introduction into Dynamic Contrast-Enhanced Ultrasound (DCE-US) for quantification of tumour perfusion","volume":"33","author":"Dietrich","year":"2012","journal-title":"Ultraschall Med"},{"key":"R35-20260105","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1055\/s-0043-119353","article-title":"Percutaneous treatment of malignant liver lesions: evaluation of success using contrast-enhanced ultrasound (CEUS) and perfusion software","volume":"39","author":"Wiesinger","year":"2018","journal-title":"Ultraschall Med"},{"key":"R36-20260105","doi-asserted-by":"crossref","first-page":"110473","DOI":"10.1016\/j.ejrad.2022.110473","article-title":"Application of DCE-US using the LI-RADS for patients with liver nodules at high risk for hepatocellular carcinoma: a preliminary study and comparison with visual interpretation","volume":"155","author":"Qiu","year":"2022","journal-title":"Eur J Radiol"},{"key":"R37-20260105","doi-asserted-by":"crossref","first-page":"238","DOI":"10.3390\/diagnostics13020238","article-title":"Prediction of pathological grades of pancreatic neuroendocrine tumors based on dynamic contrast-enhanced ultrasound quantitative analysis","volume":"13","author":"Yang","year":"2023","journal-title":"Diagnostics (Basel)"},{"key":"R38-20260105","doi-asserted-by":"crossref","first-page":"3766","DOI":"10.1007\/s00330-023-09391-9","article-title":"Comparative diagnostic performance of contrast-enhanced ultrasound and dynamic contrast-enhanced magnetic resonance imaging for differentiating clear cell and non-clear cell renal cell carcinoma","volume":"33","author":"Zhao","year":"2023","journal-title":"Eur Radiol"},{"key":"R39-20260105","doi-asserted-by":"crossref","first-page":"409","DOI":"10.3233\/CH-221681","article-title":"VueBox(R) perfusion analysis of dynamic contrast enhanced ultrasound provides added value in the diagnosis of small thyroid nodules","volume":"83","author":"Huang","year":"2023","journal-title":"Clin Hemorheol Microcirc"},{"key":"R40-20260105","doi-asserted-by":"crossref","first-page":"e17745","DOI":"10.1097\/MD.0000000000017745","article-title":"Adverse reactions after the use of SonoVue contrast agent: characteristics and nursing care experience","volume":"98","author":"Hu","year":"2019","journal-title":"Medicine (Baltimore)"},{"key":"R41-20260105","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1136\/gut.2003.030965","article-title":"Hepatic vein transit times using a microbubble agent can predict disease severity non-invasively in patients with hepatitis C","volume":"54","author":"Lim","year":"2005","journal-title":"Gut"},{"key":"R42-20260105","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1148\/radiol.2401041517","article-title":"Hepatic vein transit time of SonoVue: a comparative study with Levovist","volume":"240","author":"Lim","year":"2006","journal-title":"Radiology"},{"key":"R43-20260105","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1016\/S0140-6736(98)06373-9","article-title":"Noninvasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent","volume":"353","author":"Albrecht","year":"1999","journal-title":"Lancet"},{"key":"R44-20260105","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1136\/gut.52.8.1188","article-title":"Liver microbubble transit time compared with histology and Child-Pugh score in diffuse liver disease: a cross sectional study","volume":"52","author":"Blomley","year":"2003","journal-title":"Gut"},{"key":"R45-20260105","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1148\/radiol.2020202677","article-title":"Diagnosing portal hypertension with noninvasive subharmonic pressure estimates from a US contrast agent","volume":"298","author":"Gupta","year":"2021","journal-title":"Radiology"},{"key":"R46-20260105","doi-asserted-by":"crossref","first-page":"4354","DOI":"10.1007\/s10620-020-06790-6","article-title":"Hepatic vein contrast-enhanced ultrasound subharmonic imaging signal as a screening test for portal hypertension","volume":"66","author":"Machado","year":"2021","journal-title":"Dig Dis Sci"},{"key":"R47-20260105","doi-asserted-by":"crossref","first-page":"747095","DOI":"10.1155\/2012\/747095","article-title":"Endoscopic management of portal hypertension","volume":"2012","author":"Al-Busafi","year":"2012","journal-title":"Int J Hepatol"},{"key":"R48-20260105","doi-asserted-by":"crossref","first-page":"2373","DOI":"10.3390\/diagnostics12102373","article-title":"Application of ultrasound elastography in assessing portal hypertension","volume":"12","author":"Zhang","year":"2022","journal-title":"Diagnostics (Basel)"},{"key":"R49-20260105","doi-asserted-by":"crossref","first-page":"3051","DOI":"10.1016\/j.cgh.2019.10.018","article-title":"The role of magnetic resonance elastography in the diagnosis of noncirrhotic portal hypertension","volume":"18","author":"Navin","year":"2020","journal-title":"Clin Gastroenterol Hepatol"},{"key":"R50-20260105","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1016\/0002-9610(81)90429-3","article-title":"Radionuclide angiography of the liver and spleen. Noninvasive method for assessing the ratio of portal venous to total hepatic blood flow and portasystemic shunt patency","volume":"142","author":"Rypins","year":"1981","journal-title":"Am J Surg"}],"container-title":["Journal of Clinical Gastroenterology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MCG.0000000000002136","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T18:09:30Z","timestamp":1786039770000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MCG.0000000000002136"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,29]]},"references-count":48,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/mcg.0000000000002136","relation":{},"ISSN":["1539-2031"],"issn-type":[{"value":"1539-2031","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,29]]},"assertion":[{"value":"2024-07-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-12-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}