{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,21]],"date-time":"2026-11-21T00:14:52Z","timestamp":1795220092152,"version":"4.10.3"},"reference-count":39,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Current endoscopic retrograde cholangiopancreatography (ERCP) and cholangioscopic-based diagnostic sampling for indeterminant biliary strictures remain suboptimal. Artificial intelligence (AI)-based algorithms by means of computer vision in machine learning have been applied to cholangioscopy in an effort to improve diagnostic yield. The aim of this study was to perform a systematic review and meta-analysis to evaluate the diagnostic performance of AI-based diagnostic performance of AI-associated cholangioscopic diagnosis of indeterminant or malignant biliary strictures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Individualized searches were developed in accordance with PRISMA and MOOSE guidelines, and meta-analysis according to Cochrane Diagnostic Test Accuracy working group methodology. A bivariate model was used to compute pooled sensitivity and specificity, likelihood ratio, diagnostic odds ratio, and summary receiver operating characteristics curve (SROC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Five studies (n=675 lesions; a total of 2,685,674 cholangioscopic images) were included. All but one study analyzed a deep learning AI-based system using a convoluted neural network (CNN) with an average image processing speed of 30 to 60 frames per second. The pooled sensitivity and specificity were 95% (95% CI: 85-98) and 88% (95% CI: 76-94), with a diagnostic accuracy (SROC) of 97% (95% CI: 95-98). Sensitivity analysis of CNN studies (4 studies, 538 patients) demonstrated a pooled sensitivity, specificity, and accuracy (SROC) of 95% (95% CI: 82-99), 88% (95% CI: 72-95), and 97% (95% CI: 95-98), respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Artificial intelligence-based machine learning of cholangioscopy images appears to be a promising modality for the diagnosis of indeterminant and malignant biliary strictures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/mcg.0000000000002148","type":"journal-article","created":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T13:01:17Z","timestamp":1740488477000},"page":"855-863","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["The Role of Artificial Intelligence Combined With Digital Cholangioscopy for Indeterminant and Malignant Biliary Strictures"],"prefix":"10.1097","volume":"60","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4517-5261","authenticated-orcid":false,"given":"Thomas R.","family":"McCarty","sequence":"first","affiliation":[{"name":"Houston Methodist Hospital, Lynda K. and David M. Underwood Center for Digestive Disorders, Houston, TX"},{"name":"Weill Cornell Medical College, New York, NY"},{"name":"Texas A&M University, School of Medicine, Bryan College Station, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raj","family":"Shah","sequence":"additional","affiliation":[{"name":"The Ohio State University, Wexler School of Medicine, Division of Gastroenterology, Hepatology, and Nutrition, Columbus, OH"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronan P.","family":"Allencherril","sequence":"additional","affiliation":[{"name":"Houston Methodist Hospital, Lynda K. and David M. Underwood Center for Digestive Disorders, Houston, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nabeel","family":"Moon","sequence":"additional","affiliation":[{"name":"Houston Methodist Hospital, Lynda K. and David M. Underwood Center for Digestive Disorders, Houston, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Basile","family":"Njei","sequence":"additional","affiliation":[{"name":"Yale University School of Medicine, Investigative Medicine Program, Yale Institute for Global Health, Section of Digestive Diseases, New Haven, CT"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,10]]},"reference":[{"key":"R1-20260904","first-page":"223","article-title":"Artificial intelligence in endoscopic imaging for detection of malignant biliary strictures and cholangiocarcinoma: a systematic review","volume":"36","author":"Njei","year":"2023","journal-title":"Ann Gastroenterol"},{"key":"R2-20260904","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1056\/NEJM199910283411807","article-title":"Biliary tract cancers","volume":"341","author":"de Groen","year":"1999","journal-title":"N Engl J Med"},{"key":"R3-20260904","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1111\/j.1572-0241.1999.00786.x","article-title":"Risk factors for biliary tract cancers","volume":"94","author":"Khan","year":"1999","journal-title":"Am J Gastroenterol"},{"key":"R4-20260904","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1097\/00000658-199610000-00005","article-title":"Cholangiocarcinoma. A spectrum of intrahepatic, perihilar, and distal tumors","volume":"224","author":"Nakeeb","year":"1996","journal-title":"Ann Surg"},{"key":"R5-20260904","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1055\/s-2007-1007302","article-title":"Recent advances in the management of cholangiocarcinomas","volume":"14","author":"Vauthey","year":"1994","journal-title":"Semin Liver Dis"},{"key":"R6-20260904","first-page":"17","article-title":"Cancer statistics, 2023","volume":"73","author":"Siegel","year":"2023","journal-title":"CA Cancer J Clin"},{"key":"R7-20260904","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1053\/jhep.2001.25087","article-title":"Increasing incidence and mortality of primary intrahepatic cholangiocarcinoma in the United States","volume":"33","author":"Patel","year":"2001","journal-title":"Hepatology"},{"key":"R8-20260904","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1016\/j.jhep.2003.11.030","article-title":"Rising incidence of intrahepatic cholangiocarcinoma in the United States: a true increase?","volume":"40","author":"Shaib","year":"2004","journal-title":"J Hepatol"},{"key":"R9-20260904","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1038\/s41572-021-00300-2","article-title":"Cholangiocarcinoma","volume":"7","author":"Brindley","year":"2021","journal-title":"Nat Rev Dis Primers"},{"key":"R10-20260904","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.gie.2014.09.017","article-title":"Comparative effectiveness of biliary brush cytology and intraductal biopsy for detection of malignant biliary strictures: a systematic review and meta-analysis","volume":"81","author":"Navaneethan","year":"2015","journal-title":"Gastrointest Endosc"},{"key":"R11-20260904","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1111\/apt.13817","article-title":"Systematic review with meta-analysis: endoscopic retrograde cholangiopancreatography-based modalities for the diagnosis of cholangiocarcinoma in primary sclerosing cholangitis","volume":"44","author":"Njei","year":"2016","journal-title":"Aliment Pharmacol Ther"},{"key":"R12-20260904","doi-asserted-by":"crossref","first-page":"2631774521993059","DOI":"10.1177\/2631774521993059","article-title":"Application of artificial intelligence in pancreaticobiliary diseases","volume":"14","author":"Goyal","year":"2021","journal-title":"Ther Adv Gastrointest Endosc"},{"key":"R13-20260904","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1016\/j.gie.2022.07.005","article-title":"Artificial intelligence-assisted cholangioscopy for automatic detection of malignant biliary strictures","volume":"96","author":"Njei","year":"2022","journal-title":"Gastrointest Endosc"},{"key":"R14-20260904","doi-asserted-by":"crossref","first-page":"571","DOI":"10.5009\/gnl15063","article-title":"Prevalence, Diagnosis and Management of Pancreatic Cystic Neoplasms: Current Status and Future Directions","volume":"9","author":"Farrell","year":"2015","journal-title":"Gut Liver"},{"key":"R15-20260904","doi-asserted-by":"crossref","first-page":"2008","DOI":"10.1001\/jama.283.15.2008","article-title":"Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group","volume":"283","author":"Stroup","year":"2000","journal-title":"JAMA"},{"key":"R16-20260904","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1186\/2046-4053-2-82","article-title":"Cochrane diagnostic test accuracy reviews","volume":"2","author":"Leeflang","year":"2013","journal-title":"Syst Rev"},{"key":"R18-20260904","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.gie.2017.12.025","article-title":"Technical feasibility, diagnostic yield, and safety of microforceps biopsies during EUS evaluation of pancreatic cystic lesions (with video)","volume":"87","author":"Mittal","year":"2018","journal-title":"Gastrointest Endosc"},{"key":"R19-20260904","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1002\/cncy.21988","article-title":"Moray micro forceps biopsy improves the diagnosis of specific pancreatic cysts","volume":"126","author":"Zhang","year":"2018","journal-title":"Cancer Cytopathol"},{"key":"R20-20260904","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1016\/j.cgh.2010.05.017","article-title":"High prevalence of pancreatic cysts detected by screening magnetic resonance imaging examinations","volume":"8","author":"de Jong","year":"2010","journal-title":"Clin Gastroenterol Hepatol"},{"key":"R21-20260904","doi-asserted-by":"crossref","first-page":"E363","DOI":"10.1055\/s-0043-101693","article-title":"A meta-analysis of endoscopic ultrasound-fine-needle aspiration compared to endoscopic ultrasound-fine-needle biopsy: diagnostic yield and the value of onsite cytopathological assessment","volume":"5","author":"Khan","year":"2017","journal-title":"Endosc Int Open"},{"key":"R22-20260904","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1016\/j.jclinepi.2005.02.022","article-title":"Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews","volume":"58","author":"Reitsma","year":"2005","journal-title":"J Clin Epidemiol"},{"key":"R23-20260904","doi-asserted-by":"crossref","first-page":"383","DOI":"10.4103\/eus.eus_16_18","article-title":"Initial experience with EUS-guided microbiopsy forceps in diagnosing pancreatic cystic lesions: A multicenter feasibility study (with video)","volume":"7","author":"Kovacevic","year":"2018","journal-title":"Endosc Ultrasound"},{"key":"R24-20260904","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1002\/sim.1185","article-title":"Exploring sources of heterogeneity in systematic reviews of diagnostic tests","volume":"21","author":"Lijmer","year":"2002","journal-title":"Stat Med"},{"key":"R25-20260904","doi-asserted-by":"crossref","first-page":"3625","DOI":"10.1002\/sim.1091","article-title":"Approaches to heterogeneity in meta-analysis","volume":"20","author":"Petitti","year":"2001","journal-title":"Stat Med"},{"key":"R26-20260904","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.jclinepi.2019.12.021","article-title":"GRADE guidelines: 21 part 2. Test accuracy: inconsistency, imprecision, publication bias, and other domains for rating the certainty of evidence and presenting it in evidence profiles and summary of findings tables","volume":"122","author":"Schunemann","year":"2020","journal-title":"J Clin Epidemiol"},{"key":"R27-20260904","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.gie.2016.04.014","article-title":"The role of endoscopy in the diagnosis and treatment of cystic pancreatic neoplasms","volume":"84","author":"Muthusamy","year":"2016","journal-title":"Gastrointest Endosc"},{"key":"R28-20260904","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1186\/1471-2288-14-70","article-title":"Investigation of publication bias in meta-analyses of diagnostic test accuracy: a meta-epidemiological study","volume":"14","author":"van Enst","year":"2014","journal-title":"BMC Med Res Methodol"},{"key":"R29-20260904","doi-asserted-by":"crossref","first-page":"e00418","DOI":"10.14309\/ctg.0000000000000418","article-title":"Automatic Identification of Papillary Projections in Indeterminate Biliary Strictures Using Digital Single-Operator Cholangioscopy","volume":"12","author":"Ribeiro","year":"2021","journal-title":"Clin Transl Gastroenterol"},{"key":"R30-20260904","doi-asserted-by":"crossref","first-page":"4827","DOI":"10.3390\/cancers15194827","article-title":"Deep Learning for Automatic Diagnosis and Morphologic Characterization of Malignant Biliary Strictures Using Digital Cholangioscopy: A Multicentric Study","volume":"15","author":"Saraiva","year":"2023","journal-title":"Cancers (Basel)"},{"key":"R31-20260904","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.gie.2022.08.021","article-title":"Identification of patients with malignant biliary strictures using a cholangioscopy-based deep learning artificial intelligence (with video)","volume":"97","author":"Marya","year":"2023","journal-title":"Gastrointest Endosc"},{"key":"R32-20260904","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1055\/a-2034-3803","article-title":"Artificial intelligence for diagnosing neoplasia on digital cholangioscopy: development and multicenter validation of a convolutional neural network model","volume":"55","author":"Robles-Medranda","year":"2023","journal-title":"Endoscopy"},{"key":"R33-20260904","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.gie.2023.02.026","article-title":"A real-time interpretable artificial intelligence model for the cholangioscopic diagnosis of malignant biliary stricture (with videos)","volume":"98","author":"Zhang","year":"2023","journal-title":"Gastrointest Endosc"},{"key":"R34-20260904","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.14309\/01.ajg.0000771984.13549.fa","article-title":"Machine learning for classification of indeterminate biliary strictures during cholangioscopy","volume":"116","author":"Ghandour","year":"2021","journal-title":"Am J Gastroenterol"},{"key":"R35-20260904","doi-asserted-by":"crossref","first-page":"4827","DOI":"10.3390\/cancers15194827","article-title":"Deep learning for automatic diagnosis and morphologic characterization of malignant biliary strictures using digital cholangioscopy: a multicentric study","volume":"15","author":"Saraiva","year":"2023","journal-title":"cancers (Basel)"},{"key":"R36-20260904","doi-asserted-by":"crossref","first-page":"6191","DOI":"10.3748\/wjg.v27.i37.6191","article-title":"Challenges and opportunities in the application of artificial intelligence in gastroenterology and hepatology","volume":"27","author":"Christou","year":"2021","journal-title":"World J Gastroenterol"},{"key":"R37-20260904","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1016\/j.gie.2016.03.789","article-title":"Digital, single-operator cholangiopancreatoscopy in the diagnosis and management of pancreatobiliary disorders: a multicenter clinical experience (with video)","volume":"84","author":"Navaneethan","year":"2016","journal-title":"Gastrointest Endosc"},{"key":"R38-20260904","doi-asserted-by":"crossref","first-page":"e94","DOI":"10.1097\/MCG.0000000000001321","article-title":"Digital Single-operator cholangioscopy (DSOC) Improves Interobserver Agreement (IOA) and Accuracy for Evaluation of Indeterminate Biliary Strictures: the monaco classification","volume":"56","author":"Sethi","year":"2022","journal-title":"J Clin Gastroenterol"},{"key":"R39-20260904","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1055\/a-0607-2534","article-title":"Reliability and accuracy of a novel classification system using peroral cholangioscopy for the diagnosis of bile duct lesions","volume":"50","author":"Robles-Medranda","year":"2018","journal-title":"Endoscopy"},{"key":"R40-20260904","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.gie.2021.08.015","article-title":"Digital single-operator cholangioscopy interobserver study using a new classification: the Mendoza Classification (with video)","volume":"95","author":"Kahaleh","year":"2022","journal-title":"Gastrointest Endosc"}],"container-title":["Journal of Clinical Gastroenterology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MCG.0000000000002148","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T04:00:48Z","timestamp":1788494448000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MCG.0000000000002148"}},"subtitle":["A Systematic Review and Meta-analysis"],"short-title":[],"issued":{"date-parts":[[2025,2,18]]},"references-count":39,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/mcg.0000000000002148","relation":{},"ISSN":["1539-2031"],"issn-type":[{"value":"1539-2031","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,18]]},"assertion":[{"value":"2024-01-10","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}