{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T17:11:03Z","timestamp":1794330663645,"version":"4.9.0"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"52","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015,12]]},"DOI":"10.1097\/md.0000000000002170","type":"journal-article","created":{"date-parts":[[2015,12,29]],"date-time":"2015-12-29T18:40:24Z","timestamp":1451414424000},"page":"e2170","source":"Crossref","is-referenced-by-count":28,"title":["Clinical and Procedural Outcomes of 5-French versus 6-French Sheaths in Transradial Coronary Interventions"],"prefix":"10.1097","volume":"94","author":[{"given":"Alberto","family":"Polimeni","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Passafaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salvatore","family":"De Rosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sabato","family":"Sorrentino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniele","family":"Torella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carmen","family":"Spaccarotella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Annalisa","family":"Mongiardo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ciro","family":"Indolfi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-9-20210309","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/j.jacc.2004.04.034","article-title":"Radial versus femoral approach for percutaneous coronary diagnostic and interventional procedures; Systematic overview and meta-analysis of randomized trials","volume":"44","author":"Agostoni","year":"2004","journal-title":"J Am Coll Cardiol"},{"key":"R2-9-20210309","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.ahj.2008.08.023","article-title":"Radial versus femoral access for coronary angiography or intervention and the impact on major bleeding and ischemic events: a systematic review and meta-analysis of randomized trials","volume":"157","author":"Jolly","year":"2009","journal-title":"Am Heart J"},{"key":"R3-9-20210309","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1111\/j.1540-8183.2010.00603.x","article-title":"Implementation of the transradial approach for coronary procedures is not associated with an elevated complication rate and elevated radiation patient exposure","volume":"24","author":"Lehmann","year":"2011","journal-title":"J Interv Cardiol"},{"key":"R4-9-20210309","first-page":"218","article-title":"Transradial percutaneous coronary interventions: indications, success rates & clinical outcome","volume":"62","author":"Dahm","year":"2010","journal-title":"Indian Heart J"},{"key":"R5-9-20210309","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1002\/ccd.10321","article-title":"A randomized trial of 5 vs. 6 French transradial percutaneous coronary interventions","volume":"57","author":"Dahm","year":"2002","journal-title":"Catheter Cardiovasc Interv"},{"key":"R6-9-20210309","first-page":"353","article-title":"Comparison of 5 French versus 6 French guiding catheters for transradial coronary intervention: a prospective, randomized study","volume":"16","author":"Gobeil","year":"2004","journal-title":"J Invasive Cardiol"},{"key":"R7-9-20210309","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1111\/j.1540-8183.2006.00121.x","article-title":"A 5Fr catheter approach reduces patient discomfort during transradial coronary intervention compared with a 6Fr approach: a prospective randomized study","volume":"19","author":"Gwon","year":"2006","journal-title":"J Interv Cardiol"},{"key":"R8-9-20210309","doi-asserted-by":"crossref","first-page":"e75122","DOI":"10.1371\/journal.pone.0075122","article-title":"Testing the PRISMA-Equity 2012 reporting guideline: the perspectives of systematic review authors","volume":"8","author":"Burford","year":"2013","journal-title":"PLoS One"},{"key":"R9-9-20210309","first-page":"719","article-title":"Statistical aspects of the analysis of data from retrospective studies of disease","volume":"22","author":"Mantel","year":"1959","journal-title":"J Natl Cancer Inst"},{"key":"R10-9-20210309","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.ijcard.2013.11.046","article-title":"Left radial access for percutaneous coronary procedures: from neglected to performer? A meta-analysis of 14 studies including 7,603 procedures","volume":"171","author":"De Rosa","year":"2014","journal-title":"Int J Cardiol"},{"key":"R11-9-20210309","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1016\/S0895-4356(00)00242-0","article-title":"Publication and related bias in meta-analysis: power of statistical tests and prevalence in the literature","volume":"53","author":"Sterne","year":"2000","journal-title":"J Clin Epidemiol"},{"key":"R12-9-20210309","first-page":"332","article-title":"Evaluation of the usefulness of coronary catheters and 4 Fr insertion sets for transradial access coronarography in comparison with catheters and 5 Fr sets","volume":"9","author":"Chod\u00f3r","year":"2013","journal-title":"Postepy Kardiol Interwencyjnej"},{"key":"R13-9-20210309","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/S0002-9149(98)00821-2","article-title":"Ultrasonic assessment of vascular complications in coronary angiography and angioplasty after transradial approach","volume":"83","author":"Nagai","year":"1999","journal-title":"Am J Cardiol"},{"key":"R14-9-20210309","doi-asserted-by":"crossref","first-page":"930","DOI":"10.4244\/EIJV7I8A147","article-title":"Comparison of novel 6.5 Fr sheathless guiding catheters versus 5 Fr guiding catheters for transradial coronary intervention","volume":"7","author":"Chiam","year":"2011","journal-title":"EuroIntervention"},{"key":"R15-9-20210309","first-page":"1373","article-title":"Comparative study of 4Fr catheters using the ACIST variable rate injector system versus 6Fr catheters using hand manifold in diagnostic coronary angiography via transradial approach","volume":"123","author":"Hou","year":"2010","journal-title":"Chin Med J"},{"key":"R16-9-20210309","doi-asserted-by":"crossref","first-page":"1986","DOI":"10.1016\/j.amjcard.2014.03.040","article-title":"Comparison of frequency of radial artery occlusion after 4Fr versus 6Fr transradial coronary intervention (from the Novel Angioplasty USIng Coronary Accessor Trial)","volume":"113","author":"Takeshita","year":"2014","journal-title":"Am J Cardiol"},{"key":"R17-9-20210309","doi-asserted-by":"crossref","first-page":"290","DOI":"10.4070\/kcj.2007.37.7.298","article-title":"The Feasibility of 5-French transradial coronary intervention, as compared with a 6-French approach, for treating chronic total pcclusion","volume":"37","author":"Yu","year":"2007","journal-title":"Korean Circ J"},{"key":"R18-9-20210309","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s00392-008-0658-5","article-title":"Hydrophilic-coated sheaths increase the success rate of transradial coronary procedures and reduce patient discomfort but do not reduce the occlusion rate: randomized single-blind comparison of coated vs. non-coated sheaths","volume":"97","author":"Kindel","year":"2008","journal-title":"Clin Res Cardiol"},{"key":"R19-9-20210309","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1002\/ccd.22610","article-title":"Comparison of bivalirudin versus heparin on radial artery occlusion after transradial catheterization","volume":"76","author":"Plante","year":"2010","journal-title":"Catheter Cardiovasc Interv"},{"key":"R20-9-20210309","first-page":"21","article-title":"Use of 5 French guiding catheters in transradial coronary intervention procedures","volume":"27","author":"Wu","year":"2011","journal-title":"Acta Cardiol Sin"},{"key":"R21-9-20210309","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.jcin.2011.08.011","article-title":"The Leipzig prospective vascular ultrasound registry in radial artery catheterization: impact of sheath size on vascular complications","volume":"5","author":"Uhlemann","year":"2012","journal-title":"JACC Cardiovasc Interv"},{"key":"R22-9-20210309","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1007\/s12928-012-0108-1","article-title":"Access site-related complications after transradial catheterization can be reduced with smaller sheath size and statins","volume":"27","author":"Honda","year":"2012","journal-title":"Cardiovasc Interv Ther"},{"key":"R23-9-20210309","doi-asserted-by":"crossref","first-page":"350","DOI":"10.5603\/CJ.a2013.0128","article-title":"The long-term incidence and predictors of radial artery occlusion following a transradial coronary procedure","volume":"21","author":"Buturak","year":"2014","journal-title":"Cardiol J"},{"key":"R24-9-20210309","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/MCA.0000000000000166","article-title":"Standardized radial approach reduces access site complications: a prospective observational registry","volume":"26","author":"Markovic","year":"2015","journal-title":"Coron Artery Dis"},{"key":"R25-9-20210309","doi-asserted-by":"crossref","first-page":"1419","DOI":"10.1016\/j.jacc.2007.12.035","article-title":"Contrast-induced acute kidney injury","volume":"51","author":"McCullough","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"R26-9-20210309","doi-asserted-by":"crossref","first-page":"e000021","DOI":"10.1136\/openhrt-2013-000021","article-title":"Major bleeding after percutaneous coronary intervention and risk of subsequent mortality: a systematic review and meta-analysis","volume":"1","author":"Kwok","year":"2014","journal-title":"Open Heart"},{"key":"R27-9-20210309","doi-asserted-by":"crossref","first-page":"e634","DOI":"10.1097\/MD.0000000000000634","article-title":"Delayed sudden radial artery rupture after left transradial coronary catheterization: a case report","volume":"94","author":"Indolfi","year":"2015","journal-title":"Medicine (Baltimore"},{"key":"R28-9-20210309","doi-asserted-by":"crossref","first-page":"824","DOI":"10.4244\/EIJV10I7A142","article-title":"Minimising radial injury: prevention is better than cure","volume":"10","author":"Mamas","year":"2014","journal-title":"EuroIntervention"},{"key":"R29-9-20210309","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.carrev.2011.08.005","article-title":"Complications of transradial catheterization","volume":"13","author":"Dandekar","year":"2012","journal-title":"Cardiovasc Revasc Med"},{"key":"R30-9-20210309","doi-asserted-by":"crossref","first-page":"e89","DOI":"10.1016\/j.jcin.2013.11.028","article-title":"A novel quick and easy test for radial artery occlusion with the laser Doppler scan","volume":"7","author":"De Rosa","year":"2014","journal-title":"JACC Cardiovasc Interv"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000002170","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,14]],"date-time":"2021-05-14T02:55:17Z","timestamp":1620960917000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201512280-00009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12]]},"references-count":30,"journal-issue":{"issue":"52","published-print":{"date-parts":[[2015]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000002170","relation":{},"ISSN":["0025-7974"],"issn-type":[{"value":"0025-7974","type":"print"}],"subject":[],"published":{"date-parts":[[2015,12]]}}}