{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T05:59:09Z","timestamp":1789192749972,"version":"build-2803163510"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,2]]},"DOI":"10.1097\/md.0000000000005790","type":"journal-article","created":{"date-parts":[[2017,5,23]],"date-time":"2017-05-23T21:05:45Z","timestamp":1495573545000},"page":"e5790","source":"Crossref","is-referenced-by-count":8,"title":["Endoscopic radiofrequency ablation combined with fully covered self-expandable metal stent for inoperable periampullary carcinoma in a liver transplant patient"],"prefix":"10.1097","volume":"96","author":[{"given":"Qing","family":"Tian","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guijie","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yamin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zilin","family":"Cui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoye","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhongyang","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-8-20210226","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1136\/gut.30.8.1132","article-title":"Randomised trial of endoscopic endoprosthesis versus operative bypass in malignant obstructive jaundice","volume":"30","author":"Andersen","year":"1989","journal-title":"Gut"},{"key":"R2-8-20210226","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1002\/bjs.1800751207","article-title":"Endoscopic biliary endoprosthesis in the palliation of malignant obstruction of the distal common bile duct: a randomized trial","volume":"75","author":"Shepherd","year":"1988","journal-title":"Brit J Surg"},{"key":"R3-8-20210226","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.gie.2008.11.018","article-title":"Comparative performance of uncoated, self-expanding metal biliary stents of different designs in 2 diameters: final results of an international multicenter, randomized, controlled trial","volume":"70","author":"Loew","year":"2009","journal-title":"Gastrointest Endosc"},{"key":"R4-8-20210226","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/S1499-3872(13)60066-1","article-title":"Endobiliary radiofrequency ablation for malignant biliary obstruction","volume":"12","author":"Alis","year":"2013","journal-title":"Hepatobiliary Pancreat Dis Int"},{"key":"R5-8-20210226","doi-asserted-by":"crossref","first-page":"3449","DOI":"10.1007\/s10620-015-3731-8","article-title":"Analysis of endoscopic radiofrequency ablation of biliary malignant strictures in pancreatic cancer suggests potential survival benefit","volume":"60","author":"Kallis","year":"2015","journal-title":"Dig Dis Sci"},{"key":"R6-8-20210226","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1007\/s00270-012-0529-3","article-title":"Percutaneous intraductal radiofrequency ablation is a safe treatment for malignant biliary obstruction: feasibility and early results","volume":"36","author":"Mizandari","year":"2013","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R7-8-20210226","doi-asserted-by":"crossref","first-page":"2635","DOI":"10.1007\/s10620-014-3237-9","article-title":"Intraductal radiofrequency ablation for management of malignant biliary obstruction","volume":"59","author":"Rustagi","year":"2014","journal-title":"Dig Dis Sci"},{"key":"R8-8-20210226","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.jvir.2012.09.018","article-title":"Endobiliary radiofrequency ablation for reopening of occluded biliary stents: a promising technique","volume":"24","author":"Mukund","year":"2013","journal-title":"J Vasc Interv Radiol"},{"key":"R9-8-20210226","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/MOG.0b013e32835faacc","article-title":"Endoscopic radiofrequency ablation for cholangiocarcinoma","volume":"29","author":"Wadsworth","year":"2013","journal-title":"Curr Opin Gastroenterol"},{"key":"R10-8-20210226","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1016\/j.kjms.2015.05.001","article-title":"Biliary stenting for unresectable cholangiocarcinoma: a population-based study of long-term outcomes and hospital costs in Taiwan","volume":"31","author":"Yang","year":"2015","journal-title":"Kaohsiung J Med Sci"},{"key":"R11-8-20210226","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.gie.2010.09.031","article-title":"Endoscopically applied radiofrequency ablation appears to be safe in the treatment of malignant biliary obstruction","volume":"73","author":"Steel","year":"2011","journal-title":"Gastrointest Endosc"},{"key":"R12-8-20210226","doi-asserted-by":"crossref","first-page":"910897","DOI":"10.1155\/2013\/910897","article-title":"Safety and efficacy of radiofrequency ablation in the management of unresectable bile duct and pancreatic cancer: a novel palliation technique","volume":"2013","author":"Figueroa-Barojas","year":"2013","journal-title":"J Oncol"},{"key":"R13-8-20210226","first-page":"1957","article-title":"Intrahepatic biliary injuries associated with radiofrequency ablation of hepatic malignancies","volume":"124","author":"Fu","year":"2011","journal-title":"Chin Med J"},{"key":"R14-8-20210226","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1002\/bjs.7669","article-title":"Systematic review and meta-analysis of survival and disease recurrence after radiofrequency ablation for hepatocellular carcinoma","volume":"98","author":"Tiong","year":"2011","journal-title":"Brit J Surg"},{"key":"R15-8-20210226","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1055\/s-0030-1256126","article-title":"Endoscopic hemostasis using covered metallic stent placement for uncontrolled post-endoscopic sphincterotomy bleeding","volume":"43","author":"Itoi","year":"2011","journal-title":"Endoscopy"},{"key":"R16-8-20210226","doi-asserted-by":"crossref","first-page":"6","DOI":"10.3109\/08941939.2012.681832","article-title":"Habib EndoHPB: a novel endobiliary radiofrequency ablation device. An experimental study","volume":"26","author":"Zacharoulis","year":"2013","journal-title":"J Invest Sur"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000005790","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,14]],"date-time":"2021-05-14T02:41:17Z","timestamp":1620960077000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201702030-00008"}},"subtitle":["A case report"],"short-title":[],"issued":{"date-parts":[[2017,2]]},"references-count":16,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000005790","relation":{},"ISSN":["0025-7974"],"issn-type":[{"value":"0025-7974","type":"print"}],"subject":[],"published":{"date-parts":[[2017,2]]}}}