{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T19:32:59Z","timestamp":1761766379384,"version":"3.40.4"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"25","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,6]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3\u200a\u00b1\u200a17.2 (19\u201376) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff\u2013Parkinson\u2013White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0\u200a\u00b1\u200a21.0 (99\u2013177) minutes, the reconstruction time was 6.5\u200a\u00b1\u200a2.9 (3\u201314) minutes, the electrophysiologic study time was 10.4\u200a\u00b1\u200a3.4 (6\u201320) minutes, and the mapping time was 11.7\u200a\u00b1\u200a8.3 (3\u201336) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000011044","type":"journal-article","created":{"date-parts":[[2018,6,20]],"date-time":"2018-06-20T21:57:01Z","timestamp":1529531821000},"page":"e11044","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography"],"prefix":"10.1097","volume":"97","author":[{"given":"Xingfu","family":"Huang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanjia","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zheng","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liwei","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shenrong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaojiang","family":"Deng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongsheng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rucheng","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dingli","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Peng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-25-20250418","doi-asserted-by":"crossref","first-page":"1565","DOI":"10.1093\/europace\/euv344","article-title":"Near zerO fluoroscopic exPosure during catheter ablAtion of supRavenTricular arrhYthmias: the NO-PARTY multicentre randomized trial","volume":"18","author":"Casella","year":"2016","journal-title":"Europace"},{"key":"R2-25-20250418","doi-asserted-by":"crossref","first-page":"e6080","DOI":"10.1097\/MD.0000000000006080","article-title":"Ablation of idiopathic ventricular arrhythmia using zero-fluoroscopy approach with equivalent efficacy and less fatigue: a multicenter comparative study","volume":"96","author":"Wang","year":"2017","journal-title":"Medicine (Baltimore"},{"key":"R3-25-20250418","first-page":"1105","article-title":"Zero-fluoroscopy catheter ablation for idiopathic premature ventricular contractions from the aortic sinus cusp [in Chinese]","volume":"36","author":"Zhu","year":"2016","journal-title":"Nan Fang Yi Ke Da Xue Xue Bao"},{"key":"R4-25-20250418","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.hrthm.2015.09.003","article-title":"Near-zero x-ray in arrhythmia ablation using a 3-dimensional electroanatomic mapping system: a multicenter experience","volume":"13","author":"Giaccardi","year":"2016","journal-title":"Heart Rhythm"},{"key":"R5-25-20250418","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1007\/s00246-012-0207-x","article-title":"A novel technique for zero-fluoroscopy catheter ablation used to manage Wolff-Parkinson-White syndrome with a left-sided accessory pathway","volume":"33","author":"Kerst","year":"2012","journal-title":"Pediatr Cardiol"},{"key":"R6-25-20250418","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.hrthm.2011.12.025","article-title":"Contact force-controlled zero-fluoroscopy catheter ablation of right-sided and left atrial arrhythmia substrates","volume":"9","author":"Kerst","year":"2012","journal-title":"Heart Rhythm"},{"key":"R7-25-20250418","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1111\/j.1540-8159.2007.00702.x","article-title":"A nonfluoroscopic approach for electrophysiology and catheter ablation procedures using a three-dimensional navigation system","volume":"30","author":"Tuzcu","year":"2007","journal-title":"Pacing Clin Electrophysiol"},{"key":"R8-25-20250418","doi-asserted-by":"crossref","first-page":"1511","DOI":"10.1016\/j.amjcard.2016.08.014","article-title":"Meta-analysis of zero or near-zero fluoroscopy use during ablation of cardiac arrhythmias","volume":"118","author":"Yang","year":"2016","journal-title":"Am J Cardiol"},{"key":"R9-25-20250418","doi-asserted-by":"crossref","first-page":"e4487","DOI":"10.1097\/MD.0000000000004487","article-title":"Zero-fluoroscopy catheter ablation of severe drug-resistant arrhythmia guided by Ensite NavX system during pregnancy: Two case reports and literature review","volume":"95","author":"Chen","year":"2016","journal-title":"Medicine (Baltimore"},{"key":"R10-25-20250418","doi-asserted-by":"crossref","first-page":"e7726","DOI":"10.1097\/MD.0000000000007726","article-title":"Reconstruction left atrium and isolation pulmonary veins of paroxysmal atrial fibrillation using single contact force catheter with zero x-ray exposure: A CONSORT Study","volume":"96","author":"Zhang","year":"2017","journal-title":"Medicine (Baltimore"},{"key":"R11-25-20250418","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1161\/CIRCEP.109.872093","article-title":"Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping","volume":"2","author":"Ferguson","year":"2009","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R12-25-20250418","doi-asserted-by":"crossref","first-page":"1945","DOI":"10.1016\/j.hrthm.2015.05.018","article-title":"Reduction of radiation exposure during atrial fibrillation ablation using a novel fluoroscopy image integrated 3-dimensional electroanatomic mapping system: a prospective, randomized, single-blind, and controlled study","volume":"12","author":"Huo","year":"2015","journal-title":"Heart Rhythm"},{"key":"R13-25-20250418","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1161\/CIRCEP.114.001542","article-title":"Nonfluoroscopic catheter visualization in atrial fibrillation ablation: experience from 375 consecutive procedures","volume":"7","author":"Sommer","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R14-25-20250418","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1111\/jce.12606","article-title":"Relationship between contact force sensing technology and medium-term outcome of atrial fibrillation ablation: a multicenter study of 600 patients","volume":"26","author":"Jarman","year":"2015","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R15-25-20250418","doi-asserted-by":"crossref","first-page":"e003706","DOI":"10.1161\/CIRCEP.115.003706","article-title":"Safety and feasibility of a minimally fluoroscopic approach for ventricular tachycardia ablation in patients with structural heart disease: influence of the ventricular tachycardia substrate","volume":"9","author":"Cano","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R16-25-20250418","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1161\/CIRCEP.110.942672","article-title":"Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation","volume":"3","author":"Chun","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R17-25-20250418","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1007\/s10840-011-9662-1","article-title":"Trends in atrial fibrillation ablation: have we maximized the current paradigms?","volume":"34","author":"Winkle","year":"2012","journal-title":"J Interv Card Electrophysiol"},{"key":"R18-25-20250418","doi-asserted-by":"crossref","first-page":"2749","DOI":"10.1093\/eurheartj\/ehw223","article-title":"The dream of near-zero X-rays ablation comes true","volume":"37","author":"Gaita","year":"2016","journal-title":"Eur Heart J"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201806220-00025","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,18]],"date-time":"2025-04-18T14:01:22Z","timestamp":1744984882000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201806220-00025"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6]]},"references-count":18,"journal-issue":{"issue":"25","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000011044","relation":{},"ISSN":["0025-7974"],"issn-type":[{"type":"print","value":"0025-7974"}],"subject":[],"published":{"date-parts":[[2018,6]]}}}