{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T12:18:47Z","timestamp":1762431527720},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"45","license":[{"start":{"date-parts":[[2018,11,1]],"date-time":"2018-11-01T00:00:00Z","timestamp":1541030400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,11]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>To evaluate the accuracy of contrast-enhanced whole-heart magnetic resonance coronary angiography at 3.0T for assessing significant stenosis (\u226550% lumen diameter reduction) in patients with myocardial infarction, by using conventional coronary artery angiography as the reference standard, and also test the performance of that for the detection and assessment of chronic myocardial infarction (MI), compared with standard delayed-enhancement coronary magnetic resonance (DE-CMR) for the determination of infarct size.<\/jats:p>\n            <jats:p>We studied 42 consecutive patients (37 men, 5 women, mean age 58.5\u200a\u00b1\u200a10.7 years) with MI scheduled for conventional coronary angiography. Contrast-enhanced whole-heart coronary magnetic resonance angiography (CMRA) was employed after sublingual nitroglycerin (NTG) with the abdominal banding rolled tightly along the side of ribs. Finally, a 3D phase-sensitive inversion-recovery gradient-echo (3D-PSIR-GRE) sequence was performed during free breathing. The assessment of MI sizes on WH-CMRA reconstructed images and 3D-PSIR-GRE images were compared using a paired student <jats:italic toggle=\"yes\">t<\/jats:italic> test.<\/jats:p>\n            <jats:p>The acquisition of CMRA was completed in 40 (95.2%) of 42 patients, with an imaging time averaged at 9.5\u200a\u00b1\u200a3.1\u200aminutes. The average navigator efficiency was 47%. The sensitivity, specificity, and positive and negative predictive values of whole-heart CMRA for the detection of significant lesions on a segment-by-segment analysis were 91.7% (95% confidence interval [CI] 83.8\u201396.1), 84.0% (95% CI 80.0\u201387.4), 57.9% (95% CI 50.0\u201365.8), 97.7% (95% CI 95.3\u201398.9), respectively, and on a patient-based analysis 93.5% (95% CI 77.2\u201398.9), 88.9% (95% CI 50.7\u201399.4), 96.7% (95% CI 80.9\u201399.8), and 80.0% (95% CI 44.2\u201396.5), respectively. Infarcts were generally higher on the CE-CMRA technique compared with the standard technique (18.0\u200a\u00b1\u200a7.2\u200acm<jats:sup>3<\/jats:sup> vs 16.1\u200a\u00b1\u200a6.4\u200acm<jats:sup>3<\/jats:sup>; <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.0001).<\/jats:p>\n            <jats:p>Contrast-enhanced whole-heart CMRA with 3.0-T not only may permit reliable detection of significant obstructive coronary artery disease in patients with myocardial infarction, but also could identify and quantify the volume of myocardial infarction. This technique could be considered the preferred approach in patients who could not overcome longer scanning times or unable to hold their breath instead of delayed-enhancement magnetic resonance imaging for detection of infarcted myocardium. However, compared with standard imaging, the volume of myocardial infarction is slightly overestimated.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000013138","type":"journal-article","created":{"date-parts":[[2018,11,6]],"date-time":"2018-11-06T21:26:40Z","timestamp":1541539600000},"page":"e13138","source":"Crossref","is-referenced-by-count":2,"title":["3.0T Contrast-enhanced whole-heart coronary magnetic resonance angiography for simultaneous coronary artery angiography and myocardial viability in chronic myocardial infarction"],"prefix":"10.1097","volume":"97","author":[{"given":"Zhiyong","family":"Chen","sequence":"first","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bin","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qing","family":"Duan","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunjing","family":"Xue","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lianglong","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Union Hospital, Fujian Medical University, Fuzhou, People's Republic of China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230915","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jacc.2009.03.016","article-title":"Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center","volume":"54","author":"Yang","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"R2-20230915","doi-asserted-by":"crossref","first-page":"1902","DOI":"10.1161\/01.CIR.92.7.1902","article-title":"Physiological basis of myocardial contrast enhancement in fast magnetic resonance images of 2-day-old reperfused canine infarcts","volume":"92","author":"Judd","year":"1995","journal-title":"Circulation"},{"key":"R3-20230915","doi-asserted-by":"crossref","first-page":"1992","DOI":"10.1161\/01.CIR.100.19.1992","article-title":"Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function","volume":"100","author":"Kim","year":"1999","journal-title":"Circulation"},{"key":"R4-20230915","doi-asserted-by":"crossref","first-page":"2734","DOI":"10.1161\/01.CIR.101.23.2734","article-title":"Microvascular obstruction and left ventricular remodeling early after acute myocardial infarction","volume":"101","author":"Gerber","year":"2000","journal-title":"Circulation"},{"key":"R7-20230915","doi-asserted-by":"crossref","first-page":"407","DOI":"10.7326\/0003-4819-145-6-200609190-00004","article-title":"Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging","volume":"145","author":"Dewey","year":"2006","journal-title":"Ann Intern Med"},{"key":"R8-20230915","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1097\/01.rli.0000262565.89298.59","article-title":"Inversion recovery single-shot TurboFLASH for assessment of myocardial infarction at 3 Tesla","volume":"42","author":"Bauner","year":"2007","journal-title":"Invest Radiol"},{"key":"R9-20230915","doi-asserted-by":"crossref","first-page":"627","DOI":"10.2214\/AJR.04.0746","article-title":"Single- shot inversion recovery TrueFISP for assessment of myocardial infarction","volume":"186","author":"Huber","year":"2006","journal-title":"AJR"},{"key":"R10-20230915","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1148\/radiol.2373041483","article-title":"Phase sensitive inversion-recovery MR imaging in the detection of myocardial infarction","volume":"237","author":"Huber","year":"2005","journal-title":"Radiology"},{"key":"R11-20230915","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"R12-20230915","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1148\/radiology.218.1.r01ja50215","article-title":"An improved MR imaging technique for the visualization of myocardial infarction","volume":"218","author":"Simonetti","year":"2001","journal-title":"Radiology"},{"key":"R13-20230915","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1056\/NEJM200011163432003","article-title":"The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction","volume":"343","author":"Kim","year":"2000","journal-title":"N Engl J Med"},{"key":"R14-20230915","doi-asserted-by":"crossref","first-page":"1735","DOI":"10.1007\/s10554-016-0963-4","article-title":"Improved border sharpness of post-infarct scar by a novel selfnavigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach","volume":"32","author":"Rutz","year":"2016","journal-title":"Int J Cardiovasc Imaging"},{"key":"R15-20230915","doi-asserted-by":"crossref","first-page":"2027","DOI":"10.1016\/j.jacc.2006.01.059","article-title":"Effects of time, dose, and inversion time for acute myocardial infarct size measurements based on magnetic resonance imaging-delayed contrast enhancement","volume":"47","author":"Wagner","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"R16-20230915","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/S0140-6736(00)03567-4","article-title":"Visualisation of presence, location, and transmural extent of healed Q-wave and non-Q-wave myocardial infarction","volume":"357","author":"Wu","year":"2001","journal-title":"Lancet"},{"key":"R17-20230915","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.jacc.2004.03.076","article-title":"The pathologic basis of Q-wave and non-Q-wave myocardial infarction: a cardiovascular magnetic resonance study","volume":"44","author":"Moon","year":"2004","journal-title":"J Am Coll Cardiol"},{"key":"R18-20230915","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/S0140-6736(03)12389-6","article-title":"Contrast-enhanced MRI and routine single photon emission computed tomography (SPECT) perfusion imaging for detection of subendocardial myocardial infarcts: an imaging study","volume":"361","author":"Wagner","year":"2003","journal-title":"Lancet"},{"key":"R19-20230915","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1002\/mrm.10653","article-title":"Whole-heart steady-state free precession coronary artery magnetic resonance angiography","volume":"50","author":"Weber","year":"2003","journal-title":"Magn Reson Med"},{"key":"R20-20230915","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/S0735-1097(03)00714-9","article-title":"Relationship of contractile function to transmural extent of infarction in patients with chronic coronary artery disease","volume":"42","author":"Mahrholdt","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"R21-20230915","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1186\/s12968-017-0405-z","article-title":"3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography","volume":"19","author":"Ginami","year":"2017","journal-title":"J Cardiovasc Magn Reson"},{"key":"R25-20230915","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1136\/hrt.70.3.297","article-title":"Complications of diagnostic cardiac catheterisation: results from 34,041 patients in the United Kingdom confidential enquiry into cardiac catheter complications","volume":"70","author":"Bono","year":"1993","journal-title":"Br Heart J"},{"key":"R26-20230915","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1148\/radiol.2442061218","article-title":"Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: metaanalysis","volume":"244","author":"Vanhoenacker","year":"2007","journal-title":"Radiology"},{"key":"R27-20230915","doi-asserted-by":"crossref","first-page":"3042","DOI":"10.1093\/eurheartj\/ehm466","article-title":"64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis","volume":"28","author":"Abdulla","year":"2007","journal-title":"Eur Heart J"},{"key":"R28-20230915","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1161\/CIRCULATIONAHA.104.529511","article-title":"Characterization of Acute and Chronic Myocardial Infarcts by Multidetector Computed Tomography Comparison With Contrast-Enhanced Magnetic Resonance","volume":"113","author":"Bernhard","year":"2006","journal-title":"Circulation"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201811090-00063","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T21:09:37Z","timestamp":1694812177000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201811090-00063"}},"subtitle":["A single-center preliminary study"],"short-title":[],"issued":{"date-parts":[[2018,11]]},"references-count":23,"journal-issue":{"issue":"45","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000013138","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11]]}}}