{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,24]],"date-time":"2024-05-24T21:40:12Z","timestamp":1716586812422},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"49","license":[{"start":{"date-parts":[[2018,12,1]],"date-time":"2018-12-01T00:00:00Z","timestamp":1543622400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Rationale:<\/jats:title>\n            <jats:p>The purpose of this study was to estimate the efficacy and safety of percutaneous periacetabular screw (PPS) insertion assisted by screw view model of navigation (SVMN) to treat fracture of acetabulum.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patient concerns:<\/jats:title>\n            <jats:p>A 61-year-old male patient was injured in a motorcycle accident, which caused pain, swelling, deformity and limited mobility on his right hip.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Diagnoses:<\/jats:title>\n            <jats:p>He was diagnosed with fracture of acetabulum.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Interventions:<\/jats:title>\n            <jats:p>We used PPS insertion assisted by SVMN to treat fracture of acetabulum in this patient.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Outcomes:<\/jats:title>\n            <jats:p>The follow up lasted 24 months. Totally 2 screws were inserted into anterior and posterior column of acetabulum respectively and both of them displayed grade 0. Compared with the preoperative gap and step of fracture displacement, the postoperative ones were significantly reduced. It took 11.7 minutes for designing the screws, 6.7 minutes for implanting the guide wire, and 45.5 minutes for placing the screws. Intraoperative blood loss was 29\u200amL and total fluoroscopic time was 4.1 minutes. No clinical complications such as nerve vascular injury, infection and screw loosening were found after the operation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Lessons:<\/jats:title>\n            <jats:p>The study indicated that SVMN is favorable to the PPS insertion for acetabular fracture. Our lesson is that the relative position between the acetabular and the patient tracker must be static to ensure the accuracy of the entire system throughout the operation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000013316","type":"journal-article","created":{"date-parts":[[2018,12,8]],"date-time":"2018-12-08T18:09:10Z","timestamp":1544292550000},"page":"e13316","source":"Crossref","is-referenced-by-count":3,"title":["Accuracy and safety of percutaneous periacetabular screw insertion using screw view model of navigation in acetabular fracture"],"prefix":"10.1097","volume":"97","author":[{"given":"Jian-Wu","family":"Zhao","sequence":"first","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tong","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guang-Yu","family":"Chu","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xi-Wen","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Gynecology, The Second Hospital of Jilin University, Changchun, Jilin Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yao","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiu-Jie","family":"Zhu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi-Yao","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhen-De","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong-Sheng","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20240524","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.amsu.2016.08.017","article-title":"Treatment of postoperative sciatic nerve palsy after total hip arthroplasty for postoperative acetabular fracture: a case report","volume":"11","author":"Kanda","year":"2016","journal-title":"Ann Med Surg (Lond)"},{"key":"R2-20240524","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1016\/j.injury.2015.04.030","article-title":"Occult internal iliac arterial injury identified during open reduction internal fixation of an acetabular fracture: a report of two cases","volume":"46","author":"Chaus","year":"2015","journal-title":"Injury"},{"key":"R3-20240524","doi-asserted-by":"crossref","first-page":"212","DOI":"10.3928\/01477447-20090301-11","article-title":"Femoral artery intimal injury following open reduction of an acetabular fracture","volume":"32","author":"Gaheer","year":"2009","journal-title":"Orthopedics"},{"key":"R4-20240524","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1097\/00005131-200205000-00002","article-title":"Iatrogenic nerve injury in acetabular fracture surgery: a comparison of monitored and unmonitored procedures","volume":"16","author":"Haidukewych","year":"2002","journal-title":"J Orthop Trauma"},{"key":"R5-20240524","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.2106\/00004623-199308000-00005","article-title":"Injury of the sciatic nerve associated with acetabular fracture","volume":"75","author":"Fassler","year":"1993","journal-title":"J Bone Joint Surg Am"},{"key":"R6-20240524","first-page":"36","article-title":"Avascular necrosis of acetabulum: the hidden culprit of resistant deep wound infection and failed fixation of fracture acetabulum\u2014a case report","volume":"5","author":"KV","year":"2015","journal-title":"J Orthop Case Rep"},{"key":"R7-20240524","doi-asserted-by":"crossref","first-page":"684","DOI":"10.3109\/17453674.2015.1055690","article-title":"Open reduction and internal fixation aided by intraoperative 3-dimensional imaging improved the articular reduction in 72 displaced acetabular fractures","volume":"86","author":"Eckardt","year":"2015","journal-title":"Acta Orthop"},{"key":"R8-20240524","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1097\/TME.0b013e31828ecc20","article-title":"Comminuted pelvic fracture with retroperitoneal bleed in a geriatric patient: a case study","volume":"35","author":"Johnson-Vaught","year":"2013","journal-title":"Adv Emerg Nurs J"},{"key":"R9-20240524","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1097\/00005131-200109000-00012","article-title":"Attitudes of orthopaedic trauma surgeons regarding current controversies in the management of pelvic and acetabular fractures","volume":"15","author":"Morgan","year":"2001","journal-title":"J Orthop Trauma"},{"key":"R10-20240524","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.2106\/00004623-198870080-00016","article-title":"Heterotopic ossification as a complication of acetabular fracture. Prophylaxis with low-dose irradiation","volume":"70","author":"Bosse","year":"1988","journal-title":"J Bone Joint Surg Am"},{"key":"R11-20240524","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1097\/00005131-199112000-00009","article-title":"Open reduction and internal fixation of acetabular fractures: heterotopic ossification and other complications of treatment","volume":"5","author":"Kaempffe","year":"1991","journal-title":"J Orthop Trauma"},{"key":"R12-20240524","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1302\/2058-5241.3.170054","article-title":"Percutaneous fixation of acetabular fractures","volume":"3","author":"Caviglia","year":"2018","journal-title":"EFORT Open Rev"},{"key":"R13-20240524","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/j.jss.2013.05.074","article-title":"An evaluation of three-dimensional image-guided technologies in percutaneous pelvic and acetabular lag screw placement","volume":"185","author":"Xu","year":"2013","journal-title":"J Surg Res"},{"key":"R14-20240524","doi-asserted-by":"crossref","first-page":"e0066","DOI":"10.1097\/MD.0000000000010066","article-title":"Multimodal intraoperative monitoring during reduction of spine burst fracture and dislocation prevents neurologic injury","volume":"97","author":"Yu","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"R15-20240524","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1097\/01.brs.0000194788.45002.1b","article-title":"An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws","volume":"31","author":"Smith","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R16-20240524","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1097\/BOT.0000000000000091","article-title":"Three-dimensional fluoroscopy-navigated percutaneous screw fixation of acetabular fractures","volume":"28","author":"Schwabe","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R17-20240524","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1007\/s00264-017-3659-z","article-title":"Three-dimensional navigation-guided percutaneous screw fixation for nondisplaced and displaced pelvi-acetabular fractures in a major trauma centre","volume":"42","author":"Chui","year":"2018","journal-title":"Int Orthop"},{"key":"R18-20240524","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.2106\/00004623-199611000-00002","article-title":"Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury","volume":"78","author":"Matta","year":"1996","journal-title":"J Bone Joint Surg Am"},{"key":"R19-20240524","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/s00402-010-1143-y","article-title":"Anatomical considerations of the internal iliac artery in association with the ilioinguinal approach for anterior acetabular fracture fixation","volume":"131","author":"Karkare","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"key":"R20-20240524","first-page":"269","article-title":"Risk of spermatic cord injury during anterior pelvic ring and acetabular surgery: an anatomical study","volume":"3","author":"Firoozabadi","year":"2015","journal-title":"Arch Bone Jt Surg"},{"key":"R21-20240524","doi-asserted-by":"crossref","first-page":"428","DOI":"10.2106\/00004623-200303000-00004","article-title":"Injury of the femoral nerve associated with acetabular fracture","volume":"85-A","author":"Gruson","year":"2003","journal-title":"J Bone Joint Surg Am"},{"key":"R22-20240524","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1007\/s10029-015-1396-z","article-title":"Retroperitoneal anatomy of the iliohypogastric, ilioinguinal, genitofemoral, and lateral femoral cutaneous nerve: consequences for prevention and treatment of chronic inguinodynia","volume":"19","author":"Reinpold","year":"2015","journal-title":"Hernia"},{"key":"R23-20240524","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.jvs.2010.11.123","article-title":"Extrinsic compression of the external iliac artery following internal fixation of an acetabular fracture","volume":"54","author":"Koelling","year":"2011","journal-title":"J Vasc Surg"},{"key":"R24-20240524","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1097\/BOT.0b013e31815affd2","article-title":"External iliac artery thrombosis after open reduction of an acetabular fracture: a case report","volume":"22","author":"Langford","year":"2008","journal-title":"J Orthop Trauma"},{"key":"R25-20240524","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/1752-1947-2-4","article-title":"External iliac artery thrombosis associated with the ilio-inguinal approach in the management of acetabular fractures: a case report","volume":"2","author":"Klos","year":"2008","journal-title":"J Med Case Rep"},{"key":"R26-20240524","first-page":"302","article-title":"Dexon plus versus Maxon fascial closure in morbid obesity: a prospective randomized comparison","volume":"33","author":"Deitel","year":"1990","journal-title":"Can J Surg"},{"key":"R27-20240524","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1002\/bjs.1800760926","article-title":"Early prediction of late incisional hernias","volume":"76","author":"Pollock","year":"1989","journal-title":"Br J Surg"},{"key":"R28-20240524","doi-asserted-by":"crossref","first-page":"e2470","DOI":"10.1097\/MD.0000000000002470","article-title":"Comparison of isocentric C-arm 3-dimensional navigation and conventional fluoroscopy for percutaneous retrograde screwing for anterior column fracture of acetabulum an observational study","volume":"95","author":"He","year":"2016","journal-title":"Medicine"},{"key":"R29-20240524","doi-asserted-by":"crossref","first-page":"2527","DOI":"10.4103\/0366-6999.217080","article-title":"Percutaneous sacroiliac screw placement: a prospective randomized comparison of robot-assisted navigation procedures with a conventional technique","volume":"130","author":"Wang","year":"2017","journal-title":"Chin Med J (Engl)"},{"key":"R30-20240524","doi-asserted-by":"crossref","first-page":"E487","DOI":"10.1097\/BRS.0b013e31828826dd","article-title":"Comparison of teriparatide and bisphosphonate treatment to reduce pedicle screw loosening after lumbar spinal fusion surgery in postmenopausal women with osteoporosis from a bone quality perspective","volume":"38","author":"Ohtori","year":"2013","journal-title":"Spine"},{"key":"R31-20240524","first-page":"950","article-title":"Percutaneous cement-augmented screw fixation of bilateral osteoporotic sacral fracture","volume":"116","author":"Muller","year":"2013","journal-title":"Der Unfallchirurg"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201812070-00026","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,24]],"date-time":"2024-05-24T21:05:07Z","timestamp":1716584707000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201812070-00026"}},"subtitle":["A case report"],"short-title":[],"issued":{"date-parts":[[2018,12]]},"references-count":31,"journal-issue":{"issue":"49","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000013316","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,12]]}}}