{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T07:18:38Z","timestamp":1694762318181},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Rationale:<\/jats:title>\n            <jats:p>Obtaining venous access in a patient with extensive postburn scar contractures is a challenge.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patient concerns:<\/jats:title>\n            <jats:p>A 39-year-old woman suffered a burn 2 years previously with a total body surface area burn of 93%, and a burn index of 85. Reconstructive surgery was previously performed 39 times. Split-thickness skin grafting to the neck was planned. She had no accessible peripheral veins.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Diagnosis:<\/jats:title>\n            <jats:p>Difficult venous access due to excessive burn scar contractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Interventions:<\/jats:title>\n            <jats:p>Central venous catheterization was considered impossible even with ultrasound guidance. We placed a midline catheter for intraoperative venous access in a patient with extensive burn scar contractures. The midline catheter is a peripheral venous catheter placed in an arm vein.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Outcomes:<\/jats:title>\n            <jats:p>We successfully placed a midline catheter in the right brachial vein. This catheter was used for 24 days without difficulty.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Lessons:<\/jats:title>\n            <jats:p>The midline catheter is a viable choice in patients with difficult vascular access due to extensive postburn scar contractures.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000014208","type":"journal-article","created":{"date-parts":[[2019,1,17]],"date-time":"2019-01-17T03:06:45Z","timestamp":1547694405000},"page":"e14208","source":"Crossref","is-referenced-by-count":1,"title":["Ultrasound-guided placement of a midline catheter in a patient with extensive postburn contractures"],"prefix":"10.1097","volume":"98","author":[{"given":"Taisuke","family":"Yokota","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Kyorin University School of Medicine, Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joho","family":"Tokumine","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Kyorin University School of Medicine, Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alan Kawarai","family":"Lefor","sequence":"additional","affiliation":[{"name":"Department of Surgery, Jichi Medical University, Tochigi-ken"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayako","family":"Hasegawa","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Kyorin University School of Medicine, Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoko","family":"Yorozu","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Kyorin University School of Medicine, Tokyo"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"Asao","sequence":"additional","affiliation":[{"name":"Big Data Center for Integrative Analysis, Gunma University Initiative for Advanced Research, Maebashi, Gunma, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230914","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1097\/BCR.0000000000000207","article-title":"Peripherally inserted central venous catheter safety in burn care: a single-center retrospective cohort review","volume":"36","author":"Austin","year":"2015","journal-title":"J Burn Care Res"},{"key":"R2-20230914","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.jemermed.2016.05.029","article-title":"The midline catheter: a clinical review","volume":"51","author":"Adams","year":"2016","journal-title":"J Emerg Med"},{"key":"R3-20230914","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/BCR.0b013e3181cb8eaa","article-title":"Peripherally inserted central venous catheters and central venous catheters in burn patients: a comparative review","volume":"31","author":"Fearonce","year":"2010","journal-title":"J Burn Care Res"},{"key":"R4-20230914","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1097\/BCR.0b013e318254d4ab","article-title":"A survey of invasive catheter practices in U.S. burn centers","volume":"33","author":"Sheridan","year":"2012","journal-title":"J Burn Care Res"},{"key":"R5-20230914","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1056\/NEJMra011883","article-title":"Preventing complications of central venous catheterization","volume":"348","author":"McGee","year":"2003","journal-title":"N Engl J Med"},{"key":"R6-20230914","first-page":"S187","article-title":"Implementation of a midline intravenous catheter for burn patients to decrease frequent peripheral sticks and infection risk","volume":"35","author":"Robbins","year":"2014","journal-title":"J Burn Care Res"},{"key":"R7-20230914","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1016\/j.ajic.2018.01.006","article-title":"Comparison of complications in midlines versus central venous catheters: are midlines safer than central venous lines?","volume":"46","author":"Mushtaq","year":"2018","journal-title":"Am J Infect Control"},{"issue":"(6 Suppl)","key":"R8-20230914","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.7326\/M15-0744","article-title":"The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC): results from a multispecialty panel using the RAND\/UCLA appropriateness method","volume":"163","author":"Chopra","year":"2015","journal-title":"Ann Intern Med"},{"key":"R9-20230914","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1177\/1129729818761276","article-title":"The incidence of symptomatic upper limb venous thrombosis associated with midline catheter: prospective observation","volume":"19","author":"Lisova","year":"2018","journal-title":"J Vasc Access"},{"key":"R10-20230914","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/j.ijnurstu.2014.12.002","article-title":"The catheter to vein ratio and rates of symptomatic venous thromboembolism in patients with a peripherally inserted central catheter (PICC): a prospective cohort study","volume":"52","author":"Sharp","year":"2015","journal-title":"Int J Nurs Stud"},{"key":"R11-20230914","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.4065\/81.9.1159","article-title":"The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies","volume":"81","author":"Maki","year":"2006","journal-title":"Mayo Clin Proc"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201901180-00092","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T19:33:44Z","timestamp":1694720024000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201901180-00092"}},"subtitle":["A Case report"],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":11,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000014208","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,1]]}}}