{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T21:40:51Z","timestamp":1789594851638,"version":"build-2803163510"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2019,3,1]],"date-time":"2019-03-01T00:00:00Z","timestamp":1551398400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The aim of the present study was to observe the feasibility and effect of cornea slice acquired from femtosecond laser surgery, small incision lenticule extraction (SMILE) as patch graft for the prevention of drainage tube exposure and to compare with the sclera.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>The research is a prospective comparative randomized study. Patients who received Ahmed glaucoma valve implantation surgery from August 2015 to January 2017 at the Xiamen Eye Center were randomly divided into 2 groups. Group A (corneal group) included 131 cases (135 eyes), receiving the 3 layers of allogeneic cornea slices as graft. Group B (scleral group) included 124 cases (127 eyes), using the sclera as allograft. The appearance, graft, conjunctiva melting, and tube exposure were the primary observation points.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>After followed up for 6 to 20 months, a thinner appearance was seen in 3 eyes (2.2%) in the corneal graft group and 7 eyes (5.5%) in the scleral group. Conjunctiva melted and drainage tube exposed in 0 eyes (0%) in the corneal graft group and 2 eyes (1.6%) in the scleral group. One eye needed repair surgery. There was no statistical difference between the 2 groups (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&gt;\u200a.05). After surgery, the intraocular pressure was reduced significantly in both groups (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.05). The white sclera slice could be seen under the conjunctiva, thereby affecting the cosmetic appearance.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>The cornea slice acquired from SMILE surgery can effectively prevent drainage tube exposure. Moreover, it is easy to acquire, safe, and cheaper, giving the patient a better cosmetic appearance.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000014500","type":"journal-article","created":{"date-parts":[[2019,2,28]],"date-time":"2019-02-28T20:42:28Z","timestamp":1551386548000},"page":"e14500","source":"Crossref","is-referenced-by-count":9,"title":["Partial thickness cornea tissue from small incision lenticule extraction"],"prefix":"10.1097","volume":"98","author":[{"given":"Yuhong","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaofeng","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiyi","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinkun","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yazhang","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meizhu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230914","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1097\/IIO.0b013e31821e5a79","article-title":"Update on aqueous shunts in glaucoma","volume":"51","author":"Mosaed","year":"2011","journal-title":"Int Ophthalmol Clin"},{"key":"R2-20230914","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/S0161-6420(01)00598-X","article-title":"Late endophthalmitis associated with glaucoma drainage implants","volume":"108","author":"Gedde","year":"2001","journal-title":"Ophthalmology"},{"key":"R3-20230914","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/S0002-9394(14)72316-5","article-title":"Postoperative complications after Molteno implant surgery","volume":"111","author":"Melamed","year":"1991","journal-title":"Am J Ophthalmol"},{"key":"R4-20230914","first-page":"650","article-title":"Postoperative complications and visual loss after Molteno implantation","volume":"22","author":"Lutufo","year":"1991","journal-title":"Ophthalmic Surg"},{"key":"R5-20230914","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1186\/s12886-016-0196-2","article-title":"Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure","volume":"16","author":"Spierer","year":"2016","journal-title":"BMC Ophthalmol"},{"key":"R6-20230914","first-page":"532","article-title":"Scleral patch grafts with Molteno setons","volume":"18","author":"Freedman","year":"1987","journal-title":"Ophthalmic Surg"},{"key":"R7-20230914","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.1001\/archopht.1993.01090100144042","article-title":"Patch grafts of dehydrated cadaveric dura mater for tube shunt glaucoma surgery","volume":"111","author":"Brandt","year":"1993","journal-title":"Arch Ophthalmol"},{"key":"R8-20230914","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1001\/archopht.117.9.1243","article-title":"Tube erosion following insertion of a glaucoma drainage device with a pericardial patch graft","volume":"117","author":"Lama","year":"1999","journal-title":"Arch Ophthalmol"},{"key":"R9-20230914","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1177\/112067211002000302","article-title":"Sutureless human sclera donar patch graft for Ahmed glaucoma valve","volume":"20","author":"Zoppal","year":"2010","journal-title":"Eur J Ophthalmol"},{"key":"R10-20230914","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1177\/112067210501500317","article-title":"Long-term persistence of fascia lata patch graft in glaucoma drainage device surgery","volume":"15","author":"Monescillo","year":"2005","journal-title":"Eur J Ophthalmol"},{"key":"R11-20230914","doi-asserted-by":"crossref","first-page":"784709","DOI":"10.1155\/2013\/784709","article-title":"Short-outcomas of KeraSys patch graft for glaucoma drainage devices: a case series","volume":"2013","author":"Nagi","year":"2013","journal-title":"J Ophthalmol"},{"key":"R12-20230914","doi-asserted-by":"crossref","first-page":"184","DOI":"10.3928\/15428877-20110426-01","article-title":"Use of amniotic membrane graft in glaucoma shunt surgery","volume":"42","author":"Anand","year":"2011","journal-title":"Ophthalmic Surg Lasers Imaging"},{"key":"R13-20230914","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1097\/IJG.0b013e318133fc49","article-title":"Comparison of single thickness and double thickness processed pericardium patch graft in glaucoma drainage device surgery: a single surgeon comparison of outcome","volume":"17","author":"Lankaranian","year":"2008","journal-title":"J Glaucoma"},{"key":"R14-20230914","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1097\/00061198-200204000-00010","article-title":"A comparison of glaucoma drainage implant tube coverage","volume":"11","author":"Smith","year":"2002","journal-title":"J Glaucoma"},{"key":"R15-20230914","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/S0002-9394(14)72070-7","article-title":"Clear corneal graft overlying the seton tube to facilitate laser suture lysis","volume":"122","author":"Rojanapongpun","year":"1996","journal-title":"Am J Ophthalmol"},{"key":"R16-20230914","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1097\/ICO.0b013e3181814d15","article-title":"Corneal patch graft repair of exposed glaucoma drainage implants","volume":"27","author":"Singh","year":"2008","journal-title":"Cornea"},{"key":"R17-20230914","first-page":"751","article-title":"Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft)","volume":"9","author":"Erici","year":"2015","journal-title":"Clin Opthalmol"},{"key":"R18-20230914","doi-asserted-by":"crossref","first-page":"428","DOI":"10.3928\/1542-8877-20010901-13","article-title":"Repair of a late-onset filtering bieb leak using a corneal graft shaped with an excimer laser","volume":"32","author":"Mistlberger","year":"2001","journal-title":"Ophthalmic Surg Lasers"},{"key":"R19-20230914","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1097\/IJG.0b013e31826a96e8","article-title":"Outcomes of shunt tube coverage with glycerol preserved cornea versus pericardium","volume":"23","author":"Wigton","year":"2014","journal-title":"J Glaucoma"},{"key":"R20-20230914","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1097\/IJG.0b013e318241b9ff","article-title":"Gamma-irradiated cornea allograft for glaucoma surgery","volume":"22","author":"Lawrence","year":"2013","journal-title":"J Glaucoma"},{"key":"R21-20230914","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1097\/ICO.0b013e31821c9c09","article-title":"The intraoperative impression and postoperative outcomes of gamma-irradiated corneas in corneal and glaucoma patch surgery","volume":"30","author":"Daoud","year":"2011","journal-title":"Cornea"},{"key":"R22-20230914","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1097\/IJG.0b013e31821831b0","article-title":"Double use of corneal graft for descemet stripping automated endothelial keratoplasty and coverage of glaucoma drainage device tube","volume":"21","author":"Spierer","year":"2012","journal-title":"J Glaucoma"},{"key":"R23-20230914","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s10384-013-0249-5","article-title":"Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma","volume":"57","author":"Tamcelik","year":"2013","journal-title":"Jpn J Ophthalmol"},{"key":"R24-20230914","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1097\/IJG.0b013e31826ab693","article-title":"Conjunctival complications related to Ahmed glaucoma valve insertion","volume":"23","author":"Geffen","year":"2014","journal-title":"J Glaucoma"},{"key":"R25-20230914","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0002-9394(98)00394-8","article-title":"Intermediate-term clinical experience with the Ahmed glaucoma valve implant","volume":"127","author":"Huang","year":"1999","journal-title":"Am J Ophthalmol"},{"key":"R26-20230914","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/S0002-9394(03)00239-3","article-title":"Long-term follow-up of primary glaucoma surgery with Ahmed glaucoma valve implant versus trabeculectomy","volume":"136","author":"Wilson","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"R27-20230914","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1097\/IJG.0b013e31818fa73b","article-title":"Replacement of Ahmed aqueous drainage devices in eyes with device-related complications","volume":"18","author":"Smith","year":"2009","journal-title":"J Glaucoma"},{"key":"R28-20230914","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/0039-6257(90)90124-E","article-title":"Molteno implant surgery in refractory glaucoma","volume":"34","author":"Melamed","year":"1990","journal-title":"Surv Ophthalmol"},{"key":"R29-20230914","doi-asserted-by":"crossref","first-page":"196215","DOI":"10.1155\/2013\/196215","article-title":"Risk factors for tube shunt exposure: a matched case-control study","volume":"2013","author":"Koval","year":"2013","journal-title":"J Ophthalmol"},{"key":"R30-20230914","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1007\/s10384-008-0630-y","article-title":"Risk factors of implant exposure outside the conjunctiva after Ahmed glaucoma valve implantation","volume":"53","author":"Byun","year":"2009","journal-title":"Jpn J Ophthalmol"},{"key":"R31-20230914","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.ophtha.2008.09.003","article-title":"Superior versus inferior Ahmed glaucoma valve implantation","volume":"116","author":"Pakravan","year":"2009","journal-title":"Ophthalmology"},{"key":"R32-20230914","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1097\/IJG.0b013e31816299bc","article-title":"Intermediate-term outcome and success of superior versus inferior Ahmed glaucoma valve implantation","volume":"17","author":"Rachmiel","year":"2008","journal-title":"J Glaucoma"},{"key":"R33-20230914","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1186\/1471-2415-10-23","article-title":"Posterior migration of Ahmed glaucoma valve tube in a patient with Reiger anomaly: a case report","volume":"10","author":"Gupta","year":"2010","journal-title":"BMC Ophthalmol"},{"key":"R34-20230914","doi-asserted-by":"crossref","first-page":"347","DOI":"10.3928\/1081597X-20180323-01","article-title":"Treatment of corneal ectasia by implantation of an allogenic corneal lenticule","volume":"34","author":"Li","year":"2018","journal-title":"J Refract Surg"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201903010-00007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T18:33:27Z","timestamp":1694716407000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201903010-00007"}},"subtitle":["A novel patch graft in glaucoma drainage implant surgery"],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":34,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000014500","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3]]}}}