{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,21]],"date-time":"2026-02-21T01:21:33Z","timestamp":1771636893914,"version":"3.50.1"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2019,3,1]],"date-time":"2019-03-01T00:00:00Z","timestamp":1551398400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>: Supraglottic airway (SGA) device with non-inflatable cuff reduce the airway complications associated with cuff hyperinflation. The aim of the study is to determine whether the default setting of Supreme is as effective as the non-inflatable cuff devices. The oropharyngeal leak pressure was measured and compared between the Supreme and Air-Q, a typical non-inflatable cuff device. We hypothesized that the default setting of Supreme is non-inferior to the the Air-Q self-pressurized (SP) in respect to the oropharyngeal leak pressure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>: Eighty-four patients aged 1 to 7 years who were scheduled for general anesthesia, participated in the study. The patients were randomly assigned to Supreme group (n\u200a=\u200a41) or Air-Q SP group (n\u200a=\u200a43). We considered that the primary outcome, oropharyngeal leak pressure of Supreme group would be non-inferior to the Air-Q SP group, within 3\u200acmH<jats:sub>2<\/jats:sub>O. Other outcomes included tidal volume loss, difficulty of insertion, insertion time, and complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>: The oropharyngeal leak pressure of the Supreme and Air-Q SP was 19.9\u200a\u00b1\u200a4.1\u200acm H<jats:sub>2<\/jats:sub>O and 17.4\u200a\u00b1\u200a2.9\u200acm H<jats:sub>2<\/jats:sub>O, respectively. The mean differences of 2 devices (Air-Q SP\u2014Supreme) were \u22122.5\u200acm H<jats:sub>2<\/jats:sub>O, (95% confidence interval [\u22124.0 to \u22120.9], <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.002). The upper CI was smaller than the non-inferiorty margin (3\u200acm H<jats:sub>2<\/jats:sub>O). This result suggested that the default setting of Supreme was superior to the Air-Q SP with respect to the oropharyngeal leak pressure. However, there were no significant differences in tidal volume loss over time, ease of device insertion score, insertion time, and complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>: The Supreme can be used in the default setting in pediatric patients accordingly in terms of tolerable leak pressure and the stability for mechanical ventilation compared with Air-Q SP.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000014746","type":"journal-article","created":{"date-parts":[[2019,3,10]],"date-time":"2019-03-10T12:11:06Z","timestamp":1552219866000},"page":"e14746","source":"Crossref","is-referenced-by-count":8,"title":["Comparison of laryngeal mask airway supremeTM as non-inflatable cuff device and self-pressurized air-QTM in children"],"prefix":"10.1097","volume":"98","author":[{"given":"Jagyung","family":"Hwang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Boohwi","family":"Hong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoon-Hee","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Won Hyung","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yumin","family":"Jo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"SooKyoung","family":"Youn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chae Seong","family":"Lim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230914","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1186\/s12871-017-0403-6","article-title":"Pediatric supraglottic airway devices in clinical practice: a prospective observational study","volume":"17","author":"Kleine-Brueggeney","year":"2017","journal-title":"BMC Anesthesiol"},{"key":"R2-20230914","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1111\/j.1365-2044.1985.tb10789.x","article-title":"The laryngeal mask airway. Development and preliminary trials of a new type of airway","volume":"40","author":"Brain","year":"1985","journal-title":"Anaesthesia"},{"key":"R3-20230914","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1111\/j.1365-2044.1992.tb02168.x","article-title":"Cardiovascular responses to insertion of the laryngeal mask","volume":"47","author":"Wilson","year":"1992","journal-title":"Anaesthesia"},{"key":"R4-20230914","first-page":"174","article-title":"A study of the use of laryngeal mask airway (LMA) in children and its comparison with endotracheal intubation","volume":"53","author":"Jamil","year":"2009","journal-title":"Indian J Anaesth"},{"issue":"(suppl 1)","key":"R5-20230914","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1111\/j.1460-9592.2009.02997.x","article-title":"A critique of elective pediatric supraglottic airway devices","volume":"19","author":"White","year":"2009","journal-title":"Paediatr Anaesth"},{"key":"R6-20230914","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1097\/00000542-199212000-00007","article-title":"Radiologic localization of the laryngeal mask airway in children","volume":"77","author":"Goudsouzian","year":"1992","journal-title":"Anesthesiology"},{"key":"R7-20230914","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1213\/00000539-199209000-00007","article-title":"Comparative effects of LMA and ET insertion on intraocular pressure in children","volume":"75","author":"Watcha","year":"1992","journal-title":"Anesth Analg"},{"key":"R8-20230914","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1111\/j.1460-9592.2011.03703.x","article-title":"A randomized crossover comparison between the Laryngeal Mask Airway-Unique and the air-Q intubating laryngeal airway in children","volume":"22","author":"Jagannathan","year":"2012","journal-title":"Paediatr Anaesth"},{"key":"R9-20230914","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1097\/ACO.0b013e3283294d06","article-title":"Comparison of different techniques of laryngeal mask placement in children","volume":"22","author":"Ghai","year":"2009","journal-title":"Curr Opin Anaesthesiol"},{"key":"R10-20230914","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1111\/j.1460-9592.2008.02706.x","article-title":"Lower cuff pressures improve the seal of pediatric laryngeal mask airways","volume":"18","author":"Licina","year":"2008","journal-title":"Paediatr Anaesth"},{"key":"R11-20230914","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1177\/0310057X1204000614","article-title":"The self-pressurising air-Q(R) Intubating Laryngeal Airway for airway maintenance during anaesthesia in adults: a report of the first 100 uses","volume":"40","author":"Galgon","year":"2012","journal-title":"Anaesth Intensive Care"},{"key":"R12-20230914","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1111\/j.1460-9592.2011.03576.x","article-title":"Prospective evaluation of the self-pressurized air-Q intubating laryngeal airway in children","volume":"21","author":"Jagannathan","year":"2011","journal-title":"Paediatr Anaesth"},{"key":"R13-20230914","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1111\/pan.12483","article-title":"Evaluation of i-gel() airway in children: a meta-analysis","volume":"24","author":"Maitra","year":"2014","journal-title":"Paediatr Anaesth"},{"key":"R14-20230914","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1111\/j.1365-2044.2011.06960.x","article-title":"A randomised trial comparing the laryngeal mask airway Supreme with the laryngeal mask airway Unique in children","volume":"67","author":"Jagannathan","year":"2012","journal-title":"Anaesthesia"},{"key":"R15-20230914","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1007\/s12630-010-9312-6","article-title":"A comparison of the Supreme laryngeal mask airway with the Proseal laryngeal mask airway in anesthetized paralyzed adult patients: a randomized crossover study","volume":"57","author":"Tham","year":"2010","journal-title":"Can J Anaesth"},{"key":"R16-20230914","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1046\/j.1460-9592.2001.00649.x","article-title":"A comparison of four methods for assessing oropharyngeal leak pressure with the laryngeal mask airway (LMA) in paediatric patients","volume":"11","author":"Lopez-Gil","year":"2001","journal-title":"Paediatr Anaesth"},{"key":"R17-20230914","doi-asserted-by":"crossref","first-page":"56","DOI":"10.4103\/0970-9185.105798","article-title":"Comparison of clinical performance of the I-gel with LMA proseal","volume":"29","author":"Chauhan","year":"2013","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"R18-20230914","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1111\/j.1365-2044.2012.07199.x","article-title":"A randomised comparison of the self-pressurised air-QTM intubating laryngeal airway with the LMA Unique in children","volume":"67","author":"Jagannathan","year":"2012","journal-title":"Anaesthesia"},{"key":"R19-20230914","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1111\/pan.12609","article-title":"A randomized comparison of the i-gel with the self-pressurized air-Q intubating laryngeal airway in children","volume":"25","author":"Kim","year":"2015","journal-title":"Paediatr Anaesth"},{"key":"R20-20230914","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1111\/j.1365-2044.2005.04258.x","article-title":"Initial anatomic investigations of the I-gel airway: a novel supraglottic airway without inflatable cuff","volume":"60","author":"Levitan","year":"2005","journal-title":"Anaesthesia"},{"key":"R21-20230914","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1093\/bja\/aen319","article-title":"Oesophageal seal of the novel supralaryngeal airway device I-Gel in comparison with the laryngeal mask airways Classic and ProSeal using a cadaver model","volume":"102","author":"Schmidbauer","year":"2009","journal-title":"Br J Anaesth"},{"key":"R22-20230914","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1093\/bja\/77.2.295-a","article-title":"Optimal intracuff pressures with the laryngeal mask","volume":"77","author":"Brimacombe","year":"1996","journal-title":"Br J Anaesth"},{"key":"R23-20230914","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1111\/j.1365-2044.2011.06863.x","article-title":"The air-Q((R)) intubating laryngeal airway vs the LMA-ProSeal(TM): a prospective, randomised trial of airway seal pressure","volume":"66","author":"Galgon","year":"2011","journal-title":"Anaesthesia"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201903080-00037","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T19:08:29Z","timestamp":1694718509000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201903080-00037"}},"subtitle":["Randomized controlled non-inferiority study"],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":23,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000014746","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3]]}}}