{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T03:16:26Z","timestamp":1779074186568,"version":"3.51.4"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"16","license":[{"start":{"date-parts":[[2019,4,1]],"date-time":"2019-04-01T00:00:00Z","timestamp":1554076800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:sec><jats:title>Abstract<\/jats:title><jats:p>With increasing rates of device implantation, there is an increased recognition of device infection. We conducted a retrospective observational study in a tertiary care center in Lebanon, with data collected from medical records of patients presenting with cardiac implantable electronic device (CIED) infection from 2000 to 2017 with the purpose of identifying etiologies, risk factors and other parameters, and comparing them to available data from the rest of the world. We identified a total of 22 CIED infections. The most common microbial etiologies, including involvement in polymicrobial infection, were coagulase-negative staphylococci (45.5%) and<jats:italic toggle=\"yes\">Staphylococcus aureus<\/jats:italic>(22.7%). Rare cases of<jats:italic toggle=\"yes\">Brucella melitensis<\/jats:italic>,<jats:italic toggle=\"yes\">Sphingomonas paucimobilis<\/jats:italic>, and<jats:italic toggle=\"yes\">Kytococcus schroeteri<\/jats:italic>device infection were seen. Heart failure was seen in 77.3% of patients, hypertension in 68.2%, and chronic kidney disease in 50%. Skin changes were the most common presenting symptoms (86.4%). Antibiotics were given to all patients and all had their devices removed, with 36.4% undergoing new device implantation. This is the first study of CIED infections in Lebanon and the Middle East. Local epidemiology and occupational exposure must be considered while contemplating the microbial etiology of infection. Close monitoring after device implantation is important in preventing device infection that carries high risk of morbidity and mortality.<\/jats:p><\/jats:sec>","DOI":"10.1097\/md.0000000000014906","type":"journal-article","created":{"date-parts":[[2019,4,20]],"date-time":"2019-04-20T01:38:45Z","timestamp":1555724325000},"page":"e14906","source":"Crossref","is-referenced-by-count":11,"title":["Cardiac implantable electronic device infections"],"prefix":"10.1097","volume":"98","author":[{"given":"Marwan","family":"Refaat","sequence":"first","affiliation":[{"name":"Department of Internal Medicine, Division of Cardiology, American University of Beirut Medical Center, Beirut, Lebanon"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Zakka","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Emory University Hospital, Atlanta, GA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maurice","family":"Khoury","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Cardiology, American University of Beirut Medical Center, Beirut, Lebanon"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hassan","family":"Chami","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Emory University Hospital, Atlanta, GA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shareef","family":"Mansour","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Cardiology, American University of Beirut Medical Center, Beirut, Lebanon"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernard","family":"Harbieh","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Cardiology, Keserwan Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernard","family":"Abi-Saleh","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Cardiology, American University of Beirut Medical Center, Beirut, Lebanon"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdul Rahman","family":"Bizri","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Infectious Diseases, American University of Beirut Medical Center, Lebanon."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230914","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1097\/HCO.0b013e328341384e","article-title":"Cardiovascular implantable electrophysiological device-related infections: a review","volume":"26","author":"Gould","year":"2011","journal-title":"Curr Opin Cardiol"},{"key":"R2-20230914","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/j.jacc.2011.04.033","article-title":"16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008","volume":"58","author":"Greenspon","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"R3-20230914","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1161\/CIRCULATIONAHA.109.192665","article-title":"Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association","volume":"121","author":"Baddour","year":"2010","journal-title":"Circulation"},{"key":"R5-20230914","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1111\/pace.13009","article-title":"Cardiac implantable electronic device-related infection and extraction trends in the U.S","volume":"40","author":"Sridhar","year":"2017","journal-title":"PACE"},{"key":"R6-20230914","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1161\/CIRCEP.111.962753","article-title":"Microbiology and pathogenesis of cardiovascular implantable electronic device infections","volume":"5","author":"Nagpal","year":"2012","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R7-20230914","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/j.1540-8159.2006.00307.x","article-title":"Renal insufficiency and the risk of infection from pacemaker or defibrillator surgery","volume":"29","author":"Bloom","year":"2006","journal-title":"Pacing Clin Electrophysiol"},{"key":"R8-20230914","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1136\/hrt.2008.151985","article-title":"Risk factors and time delay associated with cardiac device infections: Leiden device registry","volume":"95","author":"Lekkerkerker","year":"2009","journal-title":"Heart"},{"key":"R9-20230914","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1086\/518889","article-title":"Risk factor analysis of permanent pacemaker infection","volume":"45","author":"Sohail","year":"2007","journal-title":"Clin Infect Dis"},{"key":"R10-20230914","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1161\/CIRCULATIONAHA.106.678664","article-title":"Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: results of a large prospective study","volume":"116","author":"Klug","year":"2007","journal-title":"Circulation"},{"key":"R11-20230914","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.idc.2011.09.001","article-title":"Cardiovascular implantable electronic device associated infections","volume":"26","author":"Gandhi","year":"2012","journal-title":"Infect Dis Clin North Am"},{"key":"R12-20230914","doi-asserted-by":"crossref","first-page":"1536","DOI":"10.1016\/j.jacc.2005.04.063","article-title":"The relation between patients\u2019 outcomes and the volume of cardioverter-defibrillator implantation procedures performed by physicians treating Medicare beneficiaries","volume":"46","author":"Al-Khatib","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"R13-20230914","doi-asserted-by":"crossref","first-page":"1675","DOI":"10.1016\/j.hrthm.2008.09.020","article-title":"Outcome of advisory implantable cardioverter-defibrillator replacement: one-year follow-up","author":"Gould","year":"2008","journal-title":"Heart Rhythm"},{"key":"R14-20230914","first-page":"13","article-title":"Intravascular device infections: epidemiology, diagnosis and management","author":"Gandelman","year":"2017","journal-title":"Cardiol Rev"},{"key":"R15-20230914","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1161\/CIRCULATIONAHA.110.936708","article-title":"Nonstaphylococcal infections of cardiac implantable electronic devices","volume":"121","author":"Viola","year":"2010","journal-title":"Circulation"},{"key":"R16-20230914","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1586\/eri.10.54","article-title":"Contemporary management of cardiovascular implantable electronic device infections","volume":"7","author":"Sohail","year":"2010","journal-title":"Expert Rev Anti Infect Ther"},{"key":"R17-20230914","doi-asserted-by":"crossref","first-page":"2484","DOI":"10.1093\/eurheartj\/ehv060","article-title":"Infected cardiac-implantable electronic devices: prevention, diagnosis, and treatment","volume":"36","author":"Nielsen","year":"2015","journal-title":"Eur Heart J"},{"key":"R18-20230914","doi-asserted-by":"crossref","first-page":"291","DOI":"10.3346\/jkms.2004.19.2.291","article-title":"Pacemaker lead endocarditis caused by Achromobacter xylosoxidans","volume":"19","author":"Ahn","year":"2004","journal-title":"J Korean Med Sci"},{"key":"R19-20230914","first-page":"207","article-title":"Human brucellosis: a classical infectious disease with persistent diagnostic challenges","volume":"12","author":"Araj","year":"1999","journal-title":"Clin Lab Sci"},{"key":"R20-20230914","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.jhin.2010.03.007","article-title":"Sphingomonas paucimobilis: a persistent Gram-negative nosocomial infectious organism","volume":"75","author":"Ryan","year":"2010","journal-title":"J Hosp Infect"},{"key":"R21-20230914","first-page":"283","article-title":"Characteristics of bacterial strains inhabiting the wood of coniferous trees","volume":"53","author":"Gajewska","year":"2004","journal-title":"Pol J Microbiol"},{"key":"R22-20230914","first-page":"1609","article-title":"Kytococcus schroeteri sp. nov., a novel Gram-positive actinobacterium isolated from a human clinical source","volume":"52","author":"Becker","year":"2002","journal-title":"Int J Syst Evol Microbiol"},{"key":"R23-20230914","doi-asserted-by":"crossref","DOI":"10.1136\/bcr.06.2010.3064","article-title":"Kytococcus schroeteri prosthetic valve endocarditis","author":"Yousri","year":"2010","journal-title":"BMJ Case Rep"},{"key":"R24-20230914","doi-asserted-by":"crossref","first-page":"1493","DOI":"10.3201\/eid0911.020683","article-title":"Prosthetic valve endocarditis due to Kytococcus schroeteri","volume":"9","author":"Becker","year":"2003","journal-title":"Emerg Infect Dis"},{"key":"R25-20230914","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1080\/AC.67.3.2160719","article-title":"Infections of implantable cardiac rhythm devices: predisposing factors and outcome","volume":"67","author":"Ipek","year":"2012","journal-title":"Acta Cardiol"},{"key":"R27-20230914","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1016\/j.jacc.2007.01.072","article-title":"Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections","volume":"49","author":"Sohail","year":"2007","journal-title":"J Am Coll Cardiol"},{"key":"R28-20230914","doi-asserted-by":"crossref","first-page":"604","DOI":"10.7326\/0003-4819-133-8-200010170-00011","article-title":"Diagnosis and management of infections involving implantable electrophysiologic cardiac devices","volume":"133","author":"Chua","year":"2000","journal-title":"Ann Intern Med"},{"key":"R29-20230914","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1111\/j.1540-8167.2009.01690.x","article-title":"Device-related infection among patients with pacemakers and implantable defibrillators: incidence, risk factors, and consequences","volume":"21","author":"Nery","year":"2010","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R30-20230914","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/j.amjcard.2012.01.360","article-title":"Effect of early diagnosis and treatment with percutaneous lead extraction on survival in patients with cardiac device infections","volume":"109","author":"Viganego","year":"2012","journal-title":"Am J Cardiol"},{"key":"R31-20230914","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1097\/MD.0b013e31825592a7","article-title":"Infections of cardiac implantable electronic devices: a retrospective multicenter observational study","volume":"9","author":"Viola","year":"2012","journal-title":"Medicine (Baltimore)"},{"key":"R32-20230914","doi-asserted-by":"crossref","first-page":"1727","DOI":"10.1001\/jama.2012.497","article-title":"Clinical characteristics and outcome of infective endocarditis involving implantable cardiac devices","volume":"307","author":"Athan","year":"2012","journal-title":"JAMA"},{"key":"R33-20230914","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1109\/TBME.2009.2024531","article-title":"Physiological-model-constrained noninvasive reconstruction of volumetric myocardial transmembrane potentials","volume":"57","author":"Wang","year":"2010","journal-title":"IEE Trans Biomed Eng"},{"key":"R34-20230914","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.ahj.2016.06.010","article-title":"Worldwide randomized antibiotic envelope infection prevention trial (WRAP-IT)","volume":"180","author":"Tarakji","year":"2016","journal-title":"Am Heart J"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201904190-00003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T03:33:31Z","timestamp":1721187211000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201904190-00003"}},"subtitle":["Observational data from a tertiary care center in Lebanon"],"short-title":[],"issued":{"date-parts":[[2019,4]]},"references-count":32,"journal-issue":{"issue":"16","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000014906","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4]]}}}