{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T13:57:06Z","timestamp":1768831026540,"version":"3.49.0"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"17","license":[{"start":{"date-parts":[[2019,4,1]],"date-time":"2019-04-01T00:00:00Z","timestamp":1554076800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>A mismatch between the femoral bow and intramedullary nails causes a series of complications. Previous investigations have sought to determine the curvature of the femur using the radius of the femoral bow. However, the radius of the curvature is affected by femur length. To eliminate the influence of femur length, we instead used an angle to indicate femoral curvatures.<\/jats:p>\n            <jats:p>Forty patients with intertrochanteric fractures who underwent a surgical procedure at our institution were enrolled in this study. We conducted a lateral X-ray of the contralateral femur before operation. We drew a triangle in the X-ray images using Digimizer software. The tangent values of the acute angle were used to indicate femoral curvature. The tangent values were then compared with the dimensions of currently used nails.<\/jats:p>\n            <jats:p>The average tangent value of the femurs was 0.0835\u200a\u00b1\u200a0.0147, as measured from the inner cortex and 0.0798\u200a\u00b1\u200a0.0150, as measured from the outer cortex. The tangent values were related to sex, with males having straighter femurs than females, and there was no obvious correlation between tangent values and age or femur length. Tangent value is a reliable method with a high intersurveyor consistency; femur curvatures were significantly greater than the curvatures of currently used nails.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000015073","type":"journal-article","created":{"date-parts":[[2019,4,25]],"date-time":"2019-04-25T15:44:07Z","timestamp":1556207047000},"page":"e15073","source":"Crossref","is-referenced-by-count":2,"title":["An innovative method for measuring the femoral arch"],"prefix":"10.1097","volume":"98","author":[{"given":"Dong","family":"Ren","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Trauma, The Third Hospital of Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianci","family":"Wang","sequence":"additional","affiliation":[{"name":"Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ming","family":"Li","sequence":"additional","affiliation":[{"name":"The Second Orthopaedic Department, West Branch of The Third Hospital of Hebei Medical University, Shijiazhuang, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yueju","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Trauma, The Third Hospital of Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yajie","family":"Huang","sequence":"additional","affiliation":[{"name":"Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pengcheng","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Trauma, The Third Hospital of Hebei Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230914","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1007\/BF01774565","article-title":"Die marknagelung von knochenbr\u00fcchen","volume":"19","author":"K\u00fcntscher","year":"1940","journal-title":"Klinische Wochenschrift"},{"key":"R2-20230914","doi-asserted-by":"crossref","first-page":"700","DOI":"10.2106\/JBJS.G.00517","article-title":"Nail or plate fixation of intertrochanteric hip fractures: changing pattern of practice. A review of the American Board of Orthopaedic Surgery Database","volume":"90","author":"Anglen","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20230914","doi-asserted-by":"crossref","first-page":"270","DOI":"10.5301\/hipint.5000216","article-title":"Trends in the management of intertrochanteric femur fractures in the United States 2005-2011","volume":"25","author":"Werner","year":"2015","journal-title":"Hip Int"},{"key":"R4-20230914","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.1186\/s40064-016-3206-1","article-title":"The choice of internal fixator for fractures around the femoral trochanter depends on area classification","volume":"5","author":"Kijima","year":"2016","journal-title":"Springerplus"},{"key":"R5-20230914","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1002\/rcs.81","article-title":"A surgical telemanipulator for femur shaft fracture reduction","volume":"2","author":"Westphal","year":"2006","journal-title":"Int J Med Robot"},{"key":"R6-20230914","doi-asserted-by":"crossref","first-page":"1735","DOI":"10.1007\/s00264-015-3036-8","article-title":"Displaced femoral shaft fractures treated by antegrade nailing with the assistance of an intramedullary reduction device","volume":"40","author":"Chen","year":"2016","journal-title":"Int Orthop"},{"key":"R7-20230914","first-page":"506","article-title":"Mechanics of intramedullary nails for femoral fractures","volume":"93","author":"Johnson","year":"1990","journal-title":"Der Unfallchirurg"},{"key":"R8-20230914","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1097\/00005131-200604000-00017","article-title":"Penetration of the distal femoral anterior cortex during intramedullary nailing for subtrochanteric fractures","volume":"20","author":"Pankaj","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R9-20230914","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1097\/BOT.0b013e318283f24f","article-title":"Cortical encroachment after cephalomedullary nailing of the proximal femur: evaluation of a more anatomic radius of curvature","volume":"27","author":"Bazylewicz","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R10-20230914","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1007\/s00402-016-2621-7","article-title":"3D computer graphical anatomy study of the femur: a basis for a new nail design","volume":"137","author":"Schmutz","year":"2017","journal-title":"Arch Orthop Trauma Surg"},{"key":"R11-20230914","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1097\/BOT.0b013e31829ff3c9","article-title":"Variation in the femoral bow: a novel high-throughput analysis of 3922 femurs on cross-sectional imaging","volume":"28","author":"Maratt","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R12-20230914","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1097\/00005131-200408000-00003","article-title":"Mismatch of current intramedullary nails with the anterior bow of the femur","volume":"18","author":"Egol","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R13-20230914","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1007\/s10278-012-9483-5","article-title":"Development of automated image stitching system for radiographic images","volume":"26","author":"Samsudin","year":"2013","journal-title":"J Dig Imag"},{"key":"R14-20230914","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1186\/s12893-016-0183-9","article-title":"Role of femoral anterior bow in cephalomedullary nailing: finite element analysis and new index estimation","volume":"16","author":"Dong","year":"2016","journal-title":"BMC Surgery"},{"key":"R15-20230914","first-page":"155","article-title":"Curvature of the femur and the proximal entry point for an intramedullary rod","author":"Harper","year":"1987","journal-title":"Clin Orthop Relat Res"},{"key":"R16-20230914","first-page":"314","article-title":"Form and dimension of the bone marrow cavity of the human femur with reference to the fit of intramedullary implants","volume":"91","author":"Zuber","year":"1988","journal-title":"Unfallchirurg"},{"key":"R17-20230914","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/BOT.0000000000000019","article-title":"Three-dimensional computed tomography-based modeling of sagittal cadaveric femoral bowing and implications for intramedullary nailing","volume":"28","author":"Jr","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R18-20230914","first-page":"29","article-title":"Femoral shaft bowing with age: a digital radiological study of Anatolian Caucasian adults","volume":"14","author":"Karaka\u015f","year":"2008","journal-title":"Diagn Interv Radiol"},{"key":"R19-20230914","article-title":"Long gamma nail stabilization of pathologic and impending pathologic femur fractures","author":"Damron","year":"1999","journal-title":"Univ Pa Orthop J"},{"key":"R20-20230914","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1007\/s00276-015-1495-7","article-title":"Femoral curvature variability in modern humans using three-dimensional quadric surface fitting","volume":"37","author":"Chapman","year":"2015","journal-title":"Surg Radiol Anat"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201904260-00006","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T21:23:28Z","timestamp":1694726608000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201904260-00006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4]]},"references-count":20,"journal-issue":{"issue":"17","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000015073","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4]]}}}