{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T12:08:00Z","timestamp":1792670880249,"version":"4.5.0"},"reference-count":40,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"29","license":[{"start":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T00:00:00Z","timestamp":1561939200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,7]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>To evaluate readout-segmented echoplanar (rsEPI) diffusion weighted imaging (DWI) for multiparametric (mp) magnetic resonance imaging (MRI) of the prostate compared to the established single-shot echoplanar imaging (ssEPI) sequence.<\/jats:p>\n            <jats:p>One hundred ten consecutive patients with clinical suspicion of prostate cancer underwent mp prostate MRI using both, the ssEPI and the rsEPI DWI sequence. For an objective assessment, delineation of the prostate shape on both DWI sequences was compared to T2-weighted images by measuring organ diameters. Apparent diffusion coefficient (ADC) values, image contrast and contrast-to-noise ratio (CNR) were compared between the 2 sequences on a region-of-interest-based analysis. Diagnostic accuracy for quantitative ADC-values was calculated. Histopathology from MRI\/ultrasound fusion-guided biopsy was used as reference standard. For a subjective assessment, 2 independent readers visually assessed image quality of both sequences using Likert-scales.<\/jats:p>\n            <jats:p>Delineation of the prostate shape was more accurate with rsEPI compared to ssEPI. ADC values in target lesions were not significantly different but significantly higher in the surrounding normal prostatic tissue of the transition zone. CNR was comparable between ssEPI and rsEPI. Sensitivity and specificity were good for both sequences with 84\/84% and 82\/73% with a Youden selected cut-off of ADC\u200a=\u200a0.971\u221710<jats:sup>\u22123<\/jats:sup>\u200amm<jats:sup>2<\/jats:sup>\/s for rsEPI and 1.017\u221710<jats:sup>\u22123<\/jats:sup>\u200amm<jats:sup>2<\/jats:sup>\/s for ssEPI. Anatomic artifacts were significantly less and SNR was lower on rsEPI compared to ssEPI in the subjective analysis.<\/jats:p>\n            <jats:p>Delineation of the prostate shape was more accurate with rsEPI DWI than with ssEPI DWI with less anatomic artifacts and higher subjective SNR and image quality on rsEPI DW images. Diagnostic ability of quantitative ADC-values was not significantly different between the 2 sequences. Thus, rsEPI DWI might be more suitable for prostate MRI with regard to MRI-guided targeted biopsy and therapy planning.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000016447","type":"journal-article","created":{"date-parts":[[2019,7,21]],"date-time":"2019-07-21T21:21:17Z","timestamp":1563744077000},"page":"e16447","source":"Crossref","is-referenced-by-count":14,"title":["Applicability of readout-segmented echoplanar diffusion weighted imaging for prostate MRI"],"prefix":"10.1097","volume":"98","author":[{"given":"Susanne","family":"Hellms","sequence":"first","affiliation":[{"name":"Institute for Diagnostic and Interventional Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcel","family":"Gutberlet","sequence":"additional","affiliation":[{"name":"Institute for Diagnostic and Interventional Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matti Joonas","family":"Peperhove","sequence":"additional","affiliation":[{"name":"Institute for Diagnostic and Interventional Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefanie","family":"Pertschy","sequence":"additional","affiliation":[{"name":"Institute for Diagnostic and Interventional Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Henkenberens","sequence":"additional","affiliation":[{"name":"Institute for Radiation Therapy and Special Oncology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Inga","family":"Peters","sequence":"additional","affiliation":[{"name":"Clinic for Urology and urologic Oncology, Hannover Medical School, Hannover, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Wacker","sequence":"additional","affiliation":[{"name":"Institute for Diagnostic and Interventional Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katja","family":"Derlin","sequence":"additional","affiliation":[{"name":"Institute for Diagnostic and Interventional Radiology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230914","first-page":"B5327","article-title":"Multiparametric MRI in detection and staging of prostate cancer","volume":"64","author":"Boesen","year":"2017","journal-title":"Dan Med J"},{"key":"R2-20230914","doi-asserted-by":"crossref","first-page":"343","DOI":"10.2214\/AJR.13.11046","article-title":"Accuracy of multiparametric MRI for prostate cancer detection: a meta-analysis","volume":"202","author":"de Rooij","year":"2014","journal-title":"AJR Am J Roentgenol"},{"key":"R3-20230914","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.eururo.2014.10.026","article-title":"Detection of clinically significant prostate cancer using magnetic resonance imaging-ultrasound fusion targeted biopsy: a systematic review","volume":"68","author":"Valerio","year":"2015","journal-title":"Eur Urol"},{"key":"R4-20230914","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.eururo.2010.12.009","article-title":"Magnetic resonance imaging for the detection, localisation, and characterisation of prostate cancer: recommendations from a European consensus meeting","volume":"59","author":"Dickinson","year":"2011","journal-title":"Eur Urol"},{"key":"R5-20230914","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.eururo.2015.08.052","article-title":"PI-RADS prostate imaging - reporting and data system: 2015, version 2","volume":"69","author":"Weinreb","year":"2016","journal-title":"Eur Urol"},{"key":"R6-20230914","doi-asserted-by":"crossref","first-page":"2019","DOI":"10.1007\/s00330-013-2795-0","article-title":"Influence of imaging and histological factors on prostate cancer detection and localisation on multiparametric MRI: a prospective study","volume":"23","author":"Bratan","year":"2013","journal-title":"Eur Radiol"},{"key":"R7-20230914","doi-asserted-by":"crossref","first-page":"2582","DOI":"10.1007\/s00330-014-3276-9","article-title":"MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy","volume":"24","author":"Schimmoller","year":"2014","journal-title":"Eur Radiol"},{"key":"R8-20230914","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1148\/radiol.12111683","article-title":"Differentiation of prostatitis and prostate cancer by using diffusion-weighted MR imaging and MR-guided biopsy at 3 T","volume":"267","author":"Nagel","year":"2013","journal-title":"Radiology"},{"key":"R9-20230914","doi-asserted-by":"crossref","first-page":"271","DOI":"10.2463\/mrms.2012-0054","article-title":"What is the most effective tool for detecting prostate cancer using a standard MR scanner?","volume":"12","author":"Osugi","year":"2013","journal-title":"Magn Reson Med Sci"},{"key":"R10-20230914","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1002\/jmri.23938","article-title":"Multiparametric MRI for prostate cancer localization in correlation to whole-mount histopathology","volume":"37","author":"Isebaert","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"R11-20230914","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1097\/RLI.0b013e3181b4c10e","article-title":"Correlation of ADC and T2 measurements with cell density in prostate cancer at 3.0 Tesla","volume":"44","author":"Gibbs","year":"2009","journal-title":"Invest Radiol"},{"key":"R12-20230914","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1016\/j.eururo.2014.11.037","article-title":"Magnetic resonance imaging-targeted biopsy may enhance the diagnostic accuracy of significant prostate cancer detection compared to standard transrectal ultrasound-guided biopsy: a systematic review and meta-analysis","volume":"68","author":"Schoots","year":"2015","journal-title":"Eur Urol"},{"key":"R13-20230914","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1001\/jama.2014.17942","article-title":"Comparison of MR\/ultrasound fusion-guided biopsy with ultrasound-guided biopsy for the diagnosis of prostate cancer","volume":"313","author":"Siddiqui","year":"2015","journal-title":"JAMA"},{"key":"R14-20230914","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1002\/mrm.22024","article-title":"High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition","volume":"62","author":"Porter","year":"2009","journal-title":"Magn Reson Med"},{"key":"R15-20230914","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1148\/radiol.12111494","article-title":"Readout-segmented echo-planar imaging improves the diagnostic performance of diffusion-weighted MR breast examinations at 3.0 T","volume":"263","author":"Bogner","year":"2012","journal-title":"Radiology"},{"key":"R16-20230914","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1016\/j.clinimag.2016.03.002","article-title":"Improve the image quality of orbital 3 T diffusion-weighted magnetic resonance imaging with readout-segmented echo-planar imaging","volume":"40","author":"Xu","year":"2016","journal-title":"Clin Imaging"},{"key":"R17-20230914","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.mri.2015.10.010","article-title":"Readout-segmented echo-planar imaging in the evaluation of sinonasal lesions: a comprehensive comparison of image quality in single-shot echo-planar imaging","volume":"34","author":"Zhao","year":"2016","journal-title":"Magn Reson Imaging"},{"key":"R18-20230914","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/j.neurad.2017.05.006","article-title":"Detection of cholesteatoma: high-resolution DWI using RS-EPI and parallel imaging at 3 tesla","volume":"44","author":"Algin","year":"2017","journal-title":"J Neuroradiol"},{"key":"R19-20230914","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1258\/ar.2012.120541","article-title":"Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T","volume":"54","author":"Morelli","year":"2013","journal-title":"Acta Radiol"},{"key":"R20-20230914","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1097\/RLI.0000000000000429","article-title":"Image quality and geometric distortion of modern diffusion-weighted imaging sequences in magnetic resonance imaging of the prostate","volume":"53","author":"Stocker","year":"2018","journal-title":"Invest Radiol"},{"key":"R21-20230914","doi-asserted-by":"crossref","first-page":"70","DOI":"10.2214\/AJR.14.13489","article-title":"Feasibility study of 3-T DWI of the prostate: readout-segmented versus single-shot echo-planar imaging","volume":"205","author":"Li","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"R22-20230914","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1111\/iju.12643","article-title":"Manually controlled targeted prostate biopsy with real-time fusion imaging of multiparametric magnetic resonance imaging and transrectal ultrasound: an early experience","volume":"22","author":"Shoji","year":"2015","journal-title":"Int J Urol"},{"key":"R23-20230914","doi-asserted-by":"crossref","first-page":"1707","DOI":"10.1007\/s00345-015-1525-4","article-title":"Targeted MRI\/TRUS fusion-guided biopsy in men with previous prostate biopsies using a novel registration software and multiparametric MRI PI-RADS scores: first results","volume":"33","author":"Tewes","year":"2015","journal-title":"World J Urol"},{"key":"R24-20230914","doi-asserted-by":"crossref","first-page":"2176471","DOI":"10.1155\/2017\/2176471","article-title":"Evaluation of MRI\/ultrasound fusion-guided prostate biopsy using transrectal and transperineal approaches","volume":"2017","author":"Tewes","year":"2017","journal-title":"Biomed Res Int"},{"key":"R25-20230914","doi-asserted-by":"crossref","first-page":"3597","DOI":"10.1063\/1.1696526","article-title":"Use of spin echoes in a pulsed magnetic-field gradient to study anisotropic restricted diffusion and flow","volume":"43","author":"Stejskal","year":"1965","journal-title":"J Chem Phys"},{"key":"R26-20230914","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1148\/radiol.2532081718","article-title":"Diffusion-weighted MR for differentiation of breast lesions at 3.0 T: how does selection of diffusion protocols affect diagnosis?","volume":"253","author":"Bogner","year":"2009","journal-title":"Radiology"},{"key":"R27-20230914","doi-asserted-by":"crossref","first-page":"837","DOI":"10.2307\/2531595","article-title":"Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach","volume":"44","author":"DeLong","year":"1988","journal-title":"Biometrics"},{"key":"R28-20230914","doi-asserted-by":"crossref","first-page":"e0162879","DOI":"10.1371\/journal.pone.0162879","article-title":"Standardized reporting of prostate MRI: comparison of the prostate imaging reporting and data system (PI-RADS) version 1 and version 2","volume":"11","author":"Tewes","year":"2016","journal-title":"PLoS One"},{"key":"R29-20230914","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.1111\/j.1464-410X.2010.09808.x","article-title":"Multiparametric magnetic resonance imaging for the detection and localization of prostate cancer: combination of T2-weighted, dynamic contrast-enhanced and diffusion-weighted imaging","volume":"107","author":"Delongchamps","year":"2011","journal-title":"BJU Int"},{"key":"R30-20230914","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.eururo.2012.06.004","article-title":"Image-guided prostate biopsy using magnetic resonance imaging-derived targets: a systematic review","volume":"63","author":"Moore","year":"2013","journal-title":"Eur Urol"},{"key":"R31-20230914","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.juro.2014.07.098","article-title":"Comparative analysis of transperineal template saturation prostate biopsy versus magnetic resonance imaging targeted biopsy with magnetic resonance imaging-ultrasound fusion guidance","volume":"193","author":"Radtke","year":"2015","journal-title":"J Urol"},{"key":"R32-20230914","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1007\/s00120-016-0268-1","article-title":"MRI\/TRUS fusion-guided prostate biopsy: value in the context of focal therapy","volume":"56","author":"Franz","year":"2017","journal-title":"Urologe A"},{"key":"R33-20230914","doi-asserted-by":"crossref","first-page":"20150034","DOI":"10.1259\/bjr.20150034","article-title":"Quantitative evaluation of diffusion-weighted imaging techniques for the purposes of radiotherapy planning in the prostate","volume":"88","author":"Liney","year":"2015","journal-title":"Br J Radiol"},{"key":"R34-20230914","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.radonc.2015.07.046","article-title":"Readout-segmented echo-planar diffusion-weighted imaging improves geometric performance for image-guided radiation therapy of pelvic tumors","volume":"117","author":"Foltz","year":"2015","journal-title":"Radiother Oncol"},{"key":"R35-20230914","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1177\/0284185117695667","article-title":"Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance","volume":"58","author":"Xu","year":"2017","journal-title":"Acta Radiol"},{"key":"R36-20230914","doi-asserted-by":"crossref","first-page":"1818","DOI":"10.1016\/j.ejrad.2016.08.008","article-title":"Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: comparison with single-shot echo-planar diffusion-weighted sequences","volume":"85","author":"Xia","year":"2016","journal-title":"Eur J Radiol"},{"key":"R37-20230914","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.mri.2017.05.004","article-title":"Combination of integrated dynamic shimming and readout-segmented echo planar imaging for diffusion weighted MRI of the head and neck region at 3Tesla","volume":"42","author":"Walter","year":"2017","journal-title":"Magn Reson Imaging"},{"key":"R38-20230914","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1007\/s00261-015-0615-5","article-title":"Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality","volume":"41","author":"Wu","year":"2016","journal-title":"Abdom Radiol (NY)"},{"key":"R39-20230914","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1002\/jmri.20969","article-title":"Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters","volume":"26","author":"Dietrich","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"R40-20230914","doi-asserted-by":"crossref","first-page":"5049","DOI":"10.1118\/1.3618730","article-title":"Measuring signal-to-noise ratio in partially parallel imaging MRI","volume":"38","author":"Goerner","year":"2011","journal-title":"Med Phys"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201907190-00034","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T20:42:48Z","timestamp":1694724168000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201907190-00034"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7]]},"references-count":40,"journal-issue":{"issue":"29","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000016447","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7]]}}}