{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T12:02:44Z","timestamp":1780660964868,"version":"3.54.1"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"33","license":[{"start":{"date-parts":[[2019,8,1]],"date-time":"2019-08-01T00:00:00Z","timestamp":1564617600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Distal radius fracture involving the lunate facet is a tough issue for surgeons, but currently there is scarcity of data on these injuries. This study aims to evaluate results of volar locking plate (VLP) for treatment of die-punch fractures of the distal radius.<\/jats:p>\n            <jats:p>Between January 2013 and June 2017, a total of 37 patients with die-punch fractures of the distal radius were admitted and underwent VLP fixation. Clinical and radiographic data on these patients were extracted from their electronic medical records. Preoperative radiographs, CT scanning and 3D reconstruction were used to definitely diagnose this injury. Radiographs taken at immediate postoperation and at last follow-up were analyzed. Data on radial subsidence, articular step-off status, volar tilt, radial inclination, wrist motion range, grip strength and related complications at the final follow-up were documented for analysis. The overall outcomes of the injured limb were evaluated, based on the Gartland and Werley scoring system.<\/jats:p>\n            <jats:p>The mean radial subsidence was 0.8\u200amm (0\u20133.3\u200amm), and articular step-off finally occurred in 4 patients (10.8%). The mean volar tilt was 9.5\u00b0 (6\u00b0\u201315\u00b0), radial inclination 21\u00b0 (12\u00b0\u201327\u00b0). The mean wrist was 84.2% in flexion of the contralateral uninjured wrist, 87.0% in extension, 92.2% in pronation and 94.5% in supination, respectively. The mean grip strength was 86% (range 56%\u2013108%) of the contralateral un-injured upper limb. Gartland and Werley score demonstrated the excellent and good rate of 83.8%, with excellent result in 21 patients, good in 10, fair in 4 and poor in 2. Incidence of overall complications was 27.0% (10\/37), with one requiring surgical intervention.<\/jats:p>\n            <jats:p>VLP demonstrated its efficacy and safety for treatment of die-punch fractures. Prospective comparative studies with larger sample are required to compare the outcomes among different fixation methods, with expectation of precise and individualized treatment for every patient.<\/jats:p>\n            <jats:p>\n                                 <jats:bold>Type of study\/level of evidence:<\/jats:bold> Therapeutic III.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000016796","type":"journal-article","created":{"date-parts":[[2019,8,15]],"date-time":"2019-08-15T14:44:20Z","timestamp":1565880260000},"page":"e16796","source":"Crossref","is-referenced-by-count":6,"title":["Outcomes of volar locking plate (VLP) fixation for treatment of die-punch fracture of the distal radius"],"prefix":"10.1097","volume":"98","author":[{"given":"Lili","family":"Yu","sequence":"first","affiliation":[{"name":"Department of Neurology, the 2nd Hospital of Hebei Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiong","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery"},{"name":"Department of Hand Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bing","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery"},{"name":"Department of Hand Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunhe","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery"},{"name":"Department of Hand Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kunlun","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery"},{"name":"Department of Hand Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dehu","family":"Tian","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery"},{"name":"Department of Hand Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanbin","family":"Bai","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery"},{"name":"Department of Hand Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R2-20230914","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.2106\/00004623-200310000-00014","article-title":"Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius","volume":"85-A","author":"Rozental","year":"2003","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20230914","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1016\/j.jhsa.2011.02.005","article-title":"A systematic review of outcomes and complications of treating unstable distal radius fractures in the elderly","volume":"36","author":"Diaz-Garcia","year":"2011","journal-title":"J Hand Surg Am"},{"key":"R4-20230914","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1016\/j.jhsa.2011.02.024","article-title":"Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures","volume":"36","author":"Ying-Chao","year":"2011","journal-title":"J Hand Surg Am"},{"key":"R5-20230914","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.jhsa.2012.10.007","article-title":"Radiographic outcomes of volar locked plating for distal radius fractures","volume":"38","author":"Mignemi","year":"2013","journal-title":"J Hand Surg Am"},{"key":"R6-20230914","doi-asserted-by":"crossref","first-page":"337","DOI":"10.2106\/00004623-196244020-00010","article-title":"Long-term follow-up of treatment of comminuted fractures of the distal end of the radius by transfixation with Kirschner wires and cast","volume":"44-A","author":"Scheck","year":"1962","journal-title":"J Bone Joint Surg Am"},{"key":"R7-20230914","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1007\/s11552-015-9757-8","article-title":"The use of a single volar locking plate for AO C3-type distal radius fractures","volume":"10","author":"Earp","year":"2015","journal-title":"Hand"},{"key":"R8-20230914","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jhsa.2005.10.010","article-title":"Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius","volume":"31","author":"Rozental","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R9-20230914","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1016\/j.jhsa.2007.05.008","article-title":"Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study","volume":"32","author":"Susanne","year":"2007","journal-title":"J Hand Surg Am"},{"key":"R10-20230914","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/00005131-200401000-00006","article-title":"Results of palmar plating of the lunate facet combined with external fixation for the treatment of high-energy compression fractures of the distal radius","volume":"18","author":"Ruch","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R11-20230914","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1016\/j.jhsa.2014.01.006","article-title":"Volar plate fixation failure for volar shearing distal radius fractures with small lunate facet fragments","volume":"39","author":"Beck","year":"2014","journal-title":"J Hand Surg Am"},{"key":"R12-20230914","first-page":"S21","article-title":"Is it really necessary to restore radial anatomic parameters after distal radius fractures?","author":"Dario","year":"2014","journal-title":"InjuryV 45"},{"key":"R13-20230914","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1177\/2151458511422701","article-title":"Assessing results after distal radius fracture treatment: a comparison of objective and subjective tools","volume":"2","author":"Kwok","year":"2011","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"R14-20230914","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/S0363-5023(96)80005-0","article-title":"Anatomic and x-ray film studies of the distal articular surface of the radius \u2020","volume":"21","author":"Md MaOM","year":"1996","journal-title":"J Hand Surg Am"},{"key":"R15-20230914","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1302\/0301-620X.78B4.0780588","article-title":"Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases","volume":"78","author":"Rikli","year":"1996","journal-title":"J Bone Joint Surg Br"},{"key":"R16-20230914","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.1016\/j.jhsa.2013.06.006","article-title":"Prospective evaluation of pronator quadratus repair following volar plate fixation of distal radius fractures","volume":"38","author":"Tosti","year":"2013","journal-title":"J Hand Surg Am"},{"key":"R17-20230914","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/BOT.0b013e3182539333","article-title":"The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures","volume":"27","author":"Hershman","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R18-20230914","first-page":"153","article-title":"Influence of incision of pronator quadratus on treatment of distal radius fracture in palm-side plate fixation","volume":"9","author":"Fang","year":"2016","journal-title":"Chin J Bone Joint Surg"},{"key":"R19-20230914","first-page":"2970","article-title":"Treatment of distal radius Die-punch fracture with volar locking plate","volume":"38","author":"Bao","year":"2012","journal-title":"Jiangsu Med J"},{"key":"R20-20230914","first-page":"1","article-title":"Treatment of die-punch fractures with 3D printing technology","author":"Chen","year":"2017","journal-title":"J Invest Surg"},{"key":"R21-20230914","first-page":"1001","article-title":"Open reduction and internal fixation for die-punch fracture of distal radius","volume":"25","author":"Xu","year":"2008","journal-title":"Orthop J China"},{"key":"R22-20230914","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.ijsu.2016.08.527","article-title":"Volar locking plate (VLP) versus non-locking plate (NLP) in the treatment of die-punch fractures of the distal radius, an observational study","author":"Zhang","year":"2016","journal-title":"Int J Surg V 34"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201908160-00040","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T22:00:42Z","timestamp":1694728842000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201908160-00040"}},"subtitle":["A retrospective single-surgeon study"],"short-title":[],"issued":{"date-parts":[[2019,8]]},"references-count":21,"journal-issue":{"issue":"33","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000016796","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8]]}}}