{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T16:39:41Z","timestamp":1743266381287},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"33","license":[{"start":{"date-parts":[[2019,8,1]],"date-time":"2019-08-01T00:00:00Z","timestamp":1564617600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Transjugular intra-hepatic portosystemic shunts (TIPS) had been considered a standard procedure in patients suffering from portal hypertension. The most challenging step in TIPS placement is blind puncture of the portal vein. We had established a localization method by introducing an Intra-Hepatic Arterial based puncture directing Localizer (IHAL) with the assistance of the enhanced computed tomography (CT) reconstruction. This study aimed to evaluate the feasibility, efficacy, and technical success of this method.<\/jats:p>\n            <jats:p>From June 2018 to August 2018, 10 consecutive patients suffering from refractory ascites or esophageal gastric bleeding by liver cirrhosis were included in this retrospective study to evaluate feasibility, efficacy, and technical success of enhanced CT assisted IHAL-guided puncture of the portal vein. As a control, 10 patients receiving TIPS placement before Jun 2018 with cone beam CT (CBCT)-guided puncture were included to compare the reduction of portal-systemic pressure gradient (PSPG), portal entry time (PET), the number of puncture, dose area product (DAP) and contrast medium consumption.<\/jats:p>\n            <jats:p>Technical success was 100% in the study group (IHAL-guided group) and in 90.0% of the control group (CBCT-guided group). Appropriate IHAL point could be achieved in all patients under the enhanced CT reconstruction assistance. The median number of punctures and DAP in IHAL group were significantly less than those in CBCT group. The reduction of PSPG, PET, and contrast medium consumption in IHAL group showed no significant differences than those in CBCT group.<\/jats:p>\n            <jats:p>Enhanced CT reconstruction assisted IHAL-guided portal vein puncture is technically feasible and a reliable tool for TIPS placement resulting in a significant reduction of the number of punctures and DAP.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000016868","type":"journal-article","created":{"date-parts":[[2019,8,15]],"date-time":"2019-08-15T14:45:23Z","timestamp":1565880323000},"page":"e16868","source":"Crossref","is-referenced-by-count":5,"title":["Intrahepatic arterial localizer guided transjugular intrahepatic portosystemic shunt placement"],"prefix":"10.1097","volume":"98","author":[{"given":"Wang","family":"Haochen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zou","family":"Yinghua","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wang","family":"Jian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230914","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1056\/NEJM199401203300303","article-title":"The transjugular intrahepatic portosystemic stent-shunt procedure for variceal bleeding","volume":"330","author":"Rossle","year":"1994","journal-title":"N Engl J Med"},{"key":"R2-20230914","doi-asserted-by":"crossref","first-page":"746","DOI":"10.2214\/AJR.12.9101","article-title":"The transjugular intrahepatic portosystemic shunt: an update","volume":"199","author":"Fidelman","year":"2012","journal-title":"Am J Roentgenol"},{"key":"R3-20230914","first-page":"306","article-title":"American Association for the Study of Liver Diseases Practice Guidelines: the role of transjugular intrahepatic portosystemic shunt creation in the management of portal hypertension","volume":"51","author":"Boyer","year":"2010","journal-title":"J Vasc Interv Radiol"},{"key":"R4-20230914","doi-asserted-by":"crossref","first-page":"87","DOI":"10.2214\/AJR.05.1342","article-title":"Transhepatic puncture of portal and hepatic veins for TIPS using a single-needle pass under sonographic guidance","volume":"187","author":"Raza","year":"2006","journal-title":"Ajr Am J Roentgenol"},{"key":"R5-20230914","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1007\/s00270-015-1087-2","article-title":"C-arm cone-beam volume CT in transjugular intrahepatic portosystemic shunt: initial clinical experience","volume":"38","author":"Luo","year":"2015","journal-title":"CardioVasc Interv Radiol"},{"key":"R6-20230914","doi-asserted-by":"crossref","first-page":"1732","DOI":"10.1007\/s00270-017-1699-9","article-title":"Three-dimensional image fusion guidance for transjugular intrahepatic portosystemic shunt placement","volume":"40","author":"Tacher","year":"2017","journal-title":"Cardiovasc Interv Radiol"},{"key":"R7-20230914","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1007\/s00270-014-0931-0","article-title":"Three-dimensional path planning software-assisted transjugular intrahepatic portosystemic shunt: a technical modification","volume":"38","author":"Tsauo","year":"2015","journal-title":"CardioVascular Interv Radiol"},{"key":"R8-20230914","doi-asserted-by":"crossref","first-page":"1594","DOI":"10.1016\/j.jvir.2012.08.023","article-title":"Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance","volume":"23","author":"Farsad","year":"2012","journal-title":"J Vasc Interv Radiol"},{"key":"R9-20230914","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1148\/radiology.184.1.1609093","article-title":"Color Doppler-US guidance in transjugular placement of intrahepatic portosystemic shunts","volume":"184","author":"Longo","year":"1992","journal-title":"Radiology"},{"key":"R10-20230914","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1148\/radiol.2512080423","article-title":"Enhancing transjugular intrahepatic portosystemic shunt puncture by using three-dimensional path planning based on the back projection of two two-dimensional portographs","volume":"251","author":"Adamus","year":"2009","journal-title":"Radiology"},{"key":"R11-20230914","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1007\/s00270-012-0493-y","article-title":"Tomas fejfar\u2026. quality improvement guidelines for transjugular intrahepatic portosystemic shunt (TIPS)","volume":"35","author":"Krajina","year":"2012","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R12-20230914","doi-asserted-by":"crossref","first-page":"3255","DOI":"10.1007\/s00330-015-3717-0","article-title":"A new angiographic imaging platform reduces radiation exposure for patients with liver cancer treated with transarterial chemoembolization","volume":"25","author":"Schernthaner","year":"2015","journal-title":"Eur Radiol"},{"key":"R13-20230914","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1007\/s00270-014-1035-6","article-title":"Impact of anatomical, procedural, and operator skill factors on the success and duration of fluoroscopy-guided transjugular intrahepatic portosystemic shunt","volume":"38","author":"Marquardt","year":"2015","journal-title":"Cardiovascular & Interventional Radiology"},{"key":"R14-20230914","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1007\/s00270-003-2634-9","article-title":"Intravascular ultrasound guidance for transjugular intrahepatic portosystemic shunt procedure in a swine model","volume":"27","author":"Kew","year":"2004","journal-title":"Cardiovasc Interv Radiol"},{"key":"R15-20230914","first-page":"21","article-title":"Intravascular ultrasound-guided direct intrahepatic portacaval shunt: description of technique and technical refinements","volume":"14","author":"Petersen","year":"2003","journal-title":"J Vasc Interv Radiol"},{"key":"R16-20230914","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1007\/s002700002529","article-title":"CT-guided transfemoral portocaval shunt creation","volume":"24","author":"Bloch","year":"2001","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R17-20230914","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/S1051-0443(99)70078-3","article-title":"MR-guided transjugular portosystemic shunt placement in a swine model","author":"Kee","year":"1999","journal-title":"J Vasc Interv Radiol V 10"},{"key":"R18-20230914","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1007\/s00270-015-1164-6","article-title":"Radiation exposure in transjugular intrahepatic portosystemic shunt creation","volume":"39","author":"Miraglia","year":"2016","journal-title":"CardioVasc Interv Radiol"},{"key":"R19-20230914","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/BF00203956","article-title":"A new coaxial needle system, hepatic artery targeting wire, and biplane fluoroscopy to increase safety and efficacy of TIPS","volume":"17","author":"Matsui","year":"1994","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R20-20230914","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1259\/bjr\/19972953","article-title":"Hepatic artery-targeting guidewire technique during transjugular intrahepatic portosystemic shunt","volume":"84","author":"Yamagami","year":"2011","journal-title":"Br J Radiol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201908160-00076","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T22:00:13Z","timestamp":1694728813000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201908160-00076"}},"subtitle":["Feasibility, efficacy, and technical success assessed by a case series-a STROBE- compliant article"],"short-title":[],"issued":{"date-parts":[[2019,8]]},"references-count":20,"journal-issue":{"issue":"33","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000016868","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8]]}}}