{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,5]],"date-time":"2025-08-05T12:01:09Z","timestamp":1754395269194},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"35","license":[{"start":{"date-parts":[[2019,8,1]],"date-time":"2019-08-01T00:00:00Z","timestamp":1564617600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>The femoral neck-preserving ratio is crucial in arthroplasty with a collum femoris-preserving (CFP) stem. The aim of our study was to analyze the relationships between the neck-preserving ratio and the short-term radiologic and clinical outcomes of patients who underwent total-hip arthroplasty (THA) with a CFP stem.<\/jats:p>\n            <jats:p>The data of 325 hips from January 2015 to December 2016 were retrospectively reviewed. The demographic and radiologic data before and after surgery were obtained from patients. The neck-preserving ratio was defined as the ratio of the preserved femoral neck length to the preoperative femoral neck length. Correlations between the neck-preserving ratio and the radiologic and clinical outcomes of patients were analyzed.<\/jats:p>\n            <jats:p>The mean neck-preserving ratio was 66.38\u200a\u00b1\u200a6.91% in the current study. We divided patients into 3 groups according to the neck-preserving ratio: group A (neck-preserving ratio \u226460.00%), group B (60.00%\u200a&lt;\u200aneck-preserving ratio\u200a&lt;\u200a70.00%), group C (neck-preserving ratio \u226570.00%). Radiologic features, including the neck-shaft angle ratio (0.96\u200a\u00b1\u200a0.05), canal fill ratio (0.64\u200a\u00b1\u200a0.07), anterior-posterior offset ratio (1.04\u200a\u00b1\u200a0.10), and lateral offset ratio (2.55\u200a\u00b1\u200a1.56) (ratios of the postoperative values to the preoperative values), and the prevalence of complications was significantly different among the groups (<jats:italic toggle=\"yes\">\u03c7<\/jats:italic>\n                                 <jats:sup>2<\/jats:sup>\u200a=\u200a21.173, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001). In the correlation analysis, we found a moderate negative correlation between the neck-preserving ratio and neck-shaft angle ratio (<jats:italic toggle=\"yes\">r<\/jats:italic>\u200a=\u200a\u22120.308, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001) and a slight positive correlation of the neck-preserving ratio with the anterior-posterior offset ratio (<jats:italic toggle=\"yes\">r<\/jats:italic>\u200a=\u200a0.415, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001) and the lateral offset ratio (<jats:italic toggle=\"yes\">r<\/jats:italic>\u200a=\u200a0.164, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.003). In the linear regression analyses, the neck-preserving ratio was significantly linearly correlated with the neck-shaft angle ratio (<jats:italic toggle=\"yes\">B<\/jats:italic>\u200a=\u200a\u22120.232, 95% confidence interval [CI]\u200a=\u200a\u22120.311 to \u22120.154, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001), anterior-posterior offset ratio (<jats:italic toggle=\"yes\">B<\/jats:italic>\u200a=\u200a0.589, 95% CI\u200a=\u200a0.447\u20130.730, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001), and lateral offset ratio (<jats:italic toggle=\"yes\">B<\/jats:italic>\u200a=\u200a3.693, 95% CI\u200a=\u200a1.256\u20136.131, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.003). However, there was no significant linear correlation between the neck-preserving ratio and the canal fill ratio (<jats:italic toggle=\"yes\">B<\/jats:italic>\u200a=\u200a0.073, 95% CI\u200a=\u200a\u22120.033 to 0.180, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.174). Logistic regression analyses also showed that a sufficient neck-preserving ratio was a protective factor for periprosthetic femoral fractures (odds ratio [OR]\u200a=\u200a0.924, 95% CI\u200a=\u200a0.859\u20130.994, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.035), dislocations (OR\u200a=\u200a0.892, 95% CI\u200a=\u200a0.796\u20130.999, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.048), and thigh pain (OR\u200a=\u200a0.886, 95% CI\u200a=\u200a0.818\u20130.960, <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.003).<\/jats:p>\n            <jats:p>For CFP stems, an insufficient neck-preserving ratio is significantly correlated with poor radiologic and clinical outcomes. Therefore, surgeons should be cognizant to preserve a sufficient femoral neck length during surgery to improve the outcomes for patients undergoing THA with CFP stems.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000016926","type":"journal-article","created":{"date-parts":[[2019,8,29]],"date-time":"2019-08-29T14:30:50Z","timestamp":1567089050000},"page":"e16926","source":"Crossref","is-referenced-by-count":10,"title":["Relationships between the femoral neck-preserving ratio and radiologic and clinical outcomes in patients undergoing total-hip arthroplasty with a collum femoris-preserving stem"],"prefix":"10.1097","volume":"98","author":[{"given":"Zeming","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hongpeng","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sikai","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jia","family":"Huo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mengnan","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongtai","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230914","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1007\/s00264-010-1020-x","article-title":"Mid-term results of 155 patients treated with a collum femoris preserving (CFP) short stem prosthesis","volume":"35","author":"Briem","year":"2011","journal-title":"Int Orthop"},{"key":"R2-20230914","doi-asserted-by":"crossref","first-page":"e5215","DOI":"10.1097\/MD.0000000000005215","article-title":"Short-stem prostheses in primary total hip arthroplasty: a meta-analysis of randomized controlled trials","volume":"95","author":"Huo","year":"2016","journal-title":"Medicine"},{"key":"R3-20230914","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.arth.2006.02.169","article-title":"Cementless alumina-on-alumina total hip arthroplasty in patients younger than 50 years: a 5-year minimum follow-up study","volume":"22","author":"Ha","year":"2007","journal-title":"J Arthroplasty"},{"key":"R4-20230914","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.1016\/j.arth.2019.03.031","article-title":"Incidence, classification, and risk factors for intraoperative periprosthetic femoral fractures in patients undergoing total hip arthroplasty with a single stem: a retrospective study","volume":"34","author":"Liu","year":"2019","journal-title":"J Arthroplasty"},{"key":"R5-20230914","first-page":"5","article-title":"Femoral neck preservation in total hip replacement","volume":"19","author":"Pipino","year":"1993","journal-title":"Ital J Orthop Traumatol"},{"key":"R6-20230914","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s101950070026","article-title":"Preservation of the femoral neck in hip arthroplasty: results of a 13- to 17-year follow-up","volume":"1","author":"Pipino","year":"2000","journal-title":"J Orthop Traumatol"},{"key":"R7-20230914","doi-asserted-by":"crossref","first-page":"S6","DOI":"10.3928\/01477447-20150215-50","article-title":"Current concepts, classification, and results in short stem hip arthroplasty","volume":"38","author":"Falez","year":"2015","journal-title":"Orthopedics"},{"key":"R8-20230914","doi-asserted-by":"crossref","first-page":"700","DOI":"10.3928\/01477447-20130821-06","article-title":"Outcomes of short stems in total hip arthroplasty","volume":"36","author":"Banerjee","year":"2013","journal-title":"Orthopedics"},{"key":"R9-20230914","doi-asserted-by":"crossref","first-page":"27","DOI":"10.5301\/HIP.2013.10718","article-title":"The collum femoris preserving stem: early results","volume":"23","author":"Ghera","year":"2013","journal-title":"Hip Int"},{"key":"R10-20230914","doi-asserted-by":"crossref","first-page":"623","DOI":"10.3944\/AOTT.2014.13.0060","article-title":"Analysis of the complications of the collum femoris preserving (CFP) prostheses","volume":"48","author":"Li","year":"2014","journal-title":"Acta Orthop Traumatol Turc"},{"key":"R11-20230914","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1186\/s12891-017-1702-2","article-title":"Bone preserving level of osteotomy in short-stem total hip arthroplasty does not influence stress shielding dimensions \u2013 a comparing finite elements analysis","volume":"18","author":"Burchard","year":"2017","journal-title":"BMC Musculoskelet Disord"},{"key":"R12-20230914","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1007\/s00264-016-3350-9","article-title":"What is the fate of the neck after a collum femoris preserving prosthesis? a nineteen years single center experience","volume":"41","author":"Formica","year":"2017","journal-title":"Int Orthop"},{"key":"R13-20230914","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.otsr.2009.03.010","article-title":"Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty","volume":"95","author":"Lecerf","year":"2009","journal-title":"Orthop Traumatol Surg Res"},{"key":"R14-20230914","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1186\/s13018-018-0858-2","article-title":"Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis","volume":"13","author":"Wu","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R15-20230914","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1007\/s10195-006-0120-2","article-title":"Tissue-sparing surgery: 25 years\u2019 experience with femoral neck preserving hip arthroplasty","volume":"7","author":"Pipino","year":"2006","journal-title":"J Orthop Traumatol"},{"key":"R16-20230914","doi-asserted-by":"crossref","first-page":"e12190","DOI":"10.1097\/MD.0000000000012190","article-title":"National incidence of traumatic spinal fractures in China: data from China National Fracture Study","volume":"97","author":"Liu","year":"2018","journal-title":"Medicine"},{"key":"R17-20230914","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/s00264-015-2826-3","article-title":"The influence of stem offset and neck shaft angles on the range of motion in total hip arthroplasty","volume":"40","author":"Shoji","year":"2016","journal-title":"Int Orthop"},{"key":"R18-20230914","doi-asserted-by":"crossref","first-page":"32","DOI":"10.3109\/17453674.2013.765623","article-title":"A prospective cohort study on the short collum femoris-preserving (CFP) stem using RSA and DXA","volume":"84","author":"Stergios","year":"2013","journal-title":"Acta Orthop"},{"key":"R19-20230914","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1007\/s12178-013-9187-6","article-title":"Dislocation after total hip arthroplasty","volume":"6","author":"Zahar","year":"2013","journal-title":"Curr Rev Musculoskelet Med"},{"key":"R20-20230914","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1007\/s12013-014-0401-y","article-title":"Long-term effectiveness of total hip replacement with the collum femoris preserving prosthesis","volume":"72","author":"You","year":"2015","journal-title":"Cell Biochem Biophys"},{"key":"R21-20230914","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1302\/0301-620X.96B1.31530","article-title":"The influence of femoral offset on health-related quality of life after total hip replacement","volume":"96-B","author":"Liebs","year":"2014","journal-title":"Bone Joint J"},{"key":"R22-20230914","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.jor.2018.01.026","article-title":"Restoring femoral offset is the most important technical factor in preventing total hip arthroplasty dislocation","volume":"15","author":"Forde","year":"2018","journal-title":"J Orthop"},{"key":"R23-20230914","doi-asserted-by":"crossref","first-page":"e4751","DOI":"10.1097\/MD.0000000000004751","article-title":"Clinical characteristics and risk factors of periprosthetic femoral fractures associated with hip arthroplasty: a retrospective study","volume":"95","author":"Zhang","year":"2016","journal-title":"Medicine"},{"key":"R24-20230914","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1186\/s13018-018-0981-0","article-title":"Comparison of collum femoris-preserving stems and ribbed stems in primary total hip arthroplasty","volume":"13","author":"Li","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R25-20230914","doi-asserted-by":"crossref","first-page":"e000435","DOI":"10.1136\/bmjopen-2011-000435","article-title":"What proportion of patients report long-term pain after total hip or knee replacement for osteoarthritis? A systematic review of prospective studies in unselected patients","volume":"2","author":"David","year":"2012","journal-title":"BMJ Open"},{"key":"R26-20230914","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1007\/s00068-017-0895-2","article-title":"Long-term follow-up of 1217 consecutive short-stem total hip arthroplasty (THA): a retrospective single-center experience","volume":"44","author":"Wacha","year":"2018","journal-title":"Eur J Trauma Emerg Surg"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005792-201908300-00041","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,14]],"date-time":"2023-09-14T21:44:29Z","timestamp":1694727869000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005792-201908300-00041"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8]]},"references-count":26,"journal-issue":{"issue":"35","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000016926","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8]]}}}