{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T09:43:26Z","timestamp":1694857406463},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"44","license":[{"start":{"date-parts":[[2019,11,1]],"date-time":"2019-11-01T00:00:00Z","timestamp":1572566400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Diffusion-weighted imaging <jats:bold>(<\/jats:bold>DWI) plays an important role in the diagnosis of breast cancer as well as the evaluation of treatment effects. A novel technique named b-value map based on thresholded DWI images has been proposed and can achieve good contrast for demonstrating prostate lesions only by manipulating the window width and center of the images. Its application on the breast has not yet explored, so the aim of the study was to investigate the feasibility of b-value maps based on threshold DWI for detection of breast cancer. A total of 25 patients with pathologically proven invasive ductal breast carcinoma were included and underwent preoperative magnetic resonance imaging (MRI) examinations including DWI at 3T. The capabilities to display lesions of DWI<jats:sub>b=800<\/jats:sub>, b-value maps and optimal computed DWI (cDWI) images were evaluated by using a 4-point method of scoring. Apparent diffusion coefficient (ADC) values of lesions were measured for the breast carcinoma. Mean scores indicating the display capability were compared among DWI<jats:sub>b=800<\/jats:sub>, optimal cDWI and b-value maps by using Kruskal\u2013Wallis test followed by Nemenyi test. The scores of both b-value maps (3.92\u200a\u00b1\u200a0.28) and optimal cDWI images (3.80\u200a\u00b1\u200a0.41) were higher than that of DWI<jats:sub>b=800<\/jats:sub> (3.48\u200a\u00b1\u200a0.51), with statistical differences (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.001 and <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.033, respectively). The optimal b values for manifesting breast carcinoma based on cDWI were 1000 to 1200\u200as\/mm<jats:sup>2<\/jats:sup>. The b-value map enables fast identification for breast lesions and shows similar performance to the optimal cDWI images.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000017640","type":"journal-article","created":{"date-parts":[[2019,11,4]],"date-time":"2019-11-04T19:38:47Z","timestamp":1572896327000},"page":"e17640","source":"Crossref","is-referenced-by-count":1,"title":["The feasibility of b-value maps based on threshold DWI for detection of breast cancer"],"prefix":"10.1097","volume":"98","author":[{"given":"Na","family":"Zhao","sequence":"first","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chao","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaolong","family":"Ye","sequence":"additional","affiliation":[{"name":"Department of Pathology, Changhai Hospital of Shanghai, The Second Military Medical University, Shanghai"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nimpagaritse","family":"Danie","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Caixia","family":"Fu","sequence":"additional","affiliation":[{"name":"Application Developments, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiang","family":"Hao","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianping","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Radiology"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2019,11]]},"reference":[{"key":"R1-20230915","doi-asserted-by":"crossref","first-page":"1622","DOI":"10.2214\/AJR.06.1403","article-title":"Diffusion-weighted MRI in the body: applications and challenges in oncology","volume":"18","author":"Koh","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"R2-20230915","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1007\/s00247-016-3573-3","article-title":"Diffusion-weighted imaging in pediatric body magnetic resonance imaging","volume":"46","author":"Chavhan","year":"2016","journal-title":"Pediatr Radiol"},{"key":"R3-20230915","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.2214\/AJR.16.16486","article-title":"Differentiation of benign and malignant head and neck lesions with diffusion tensor imaging and DWI","volume":"208","author":"Koontz","year":"2017","journal-title":"AJR Am J Roentgenol"},{"key":"R4-20230915","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1593\/neo.81328","article-title":"Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations","volume":"11","author":"Padhani","year":"2009","journal-title":"Neoplasia"},{"key":"R5-20230915","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/S0720-048X(02)00303-0","article-title":"Basic principles of diffusion-weighted imaging","volume":"45","author":"Bammer","year":"2003","journal-title":"Eur J Radiol"},{"key":"R6-20230915","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1177\/0284185117727787","article-title":"Diagnostic value of apparent diffusion coefficient in differentiating between high-grade gliomas and brain metastases","volume":"59","author":"Caravan","year":"2018","journal-title":"Acta Radiol"},{"key":"R7-20230915","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1007\/s00261-017-1236-y","article-title":"Quantitative MRI of kidneys in renal disease","volume":"43","author":"Kline","year":"2018","journal-title":"Abdom Radiol (NY)"},{"key":"R8-20230915","doi-asserted-by":"crossref","first-page":"17038","DOI":"10.1038\/s41598-017-16826-z","article-title":"Apparent diffusion coefficient (ADC) predicts therapy response in pancreatic ductal adenocarcinoma","volume":"7","author":"Trajkovicarsic","year":"2017","journal-title":"Sci Rep"},{"key":"R9-20230915","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1177\/0284185115612249","article-title":"Endometrial cancer: correlation of apparent diffusion coefficient (ADC) with tumor cellularity and tumor grade","volume":"57","author":"Kishimoto","year":"2016","journal-title":"Acta Radiol"},{"key":"R10-20230915","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1007\/s00270-017-1634-0","article-title":"Predicting treatment response of colorectal cancer liver metastases to conventional lipiodol-based transarterial chemoembolization using diffusion-weighted MR imaging: value of pretreatment apparent diffusion coefficients (ADC) and ADC changes under therapy","volume":"40","author":"Lahrsow","year":"2017","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R11-20230915","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.1002\/jmri.25331","article-title":"Quantitative DWI implemented after DCE-MRI Yields Increased Specificity for BI-RADS 3 and 4 breast lesions","volume":"44","author":"Dijkstra","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"R12-20230915","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1002\/jmri.24843","article-title":"Diffusion-weighted imaging in assessing pathological response of tumor in breast cancer subtype to neoadjuvant chemotherapy","volume":"42","author":"Liu","year":"2015","journal-title":"J Magn Reson Imaging"},{"key":"R13-20230915","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1002\/jmri.25353","article-title":"Optimal high b-value for diffusion weighted MRI in diagnosing high risk prostate cancers in the peripheral zone","volume":"45","author":"Agarwal","year":"2017","journal-title":"J Magn Reson Imaging"},{"key":"R14-20230915","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1097\/RCT.0000000000000702","article-title":"Preliminary results of high-precision computed diffusion weighted imaging for the diagnosis of hepatocellular carcinoma at 3 Tesla","volume":"42","author":"Akagi","year":"2018","journal-title":"J Comput Assist Tomogr"},{"key":"R15-20230915","doi-asserted-by":"crossref","first-page":"66","DOI":"10.2463\/mrms.mp.2015-0161","article-title":"Feasibility of computed diffusion weighted imaging and optimization of b-value in cervical cancer","volume":"16","author":"Moribata","year":"2017","journal-title":"Magn Reson Med Sci"},{"key":"R17-20230915","first-page":"245","article-title":"Effect of body mass index on all-cause mortality and incidence of cardiovascular diseases\u2013report for meta-analysis of prospective studies open optimal cut-off points of body mass index in Chinese adults","volume":"15","author":"Zhou","year":"2002","journal-title":"Biomed Environ Sci"},{"key":"R18-20230915","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1002\/jmri.25131","article-title":"Evaluating the diagnostic sensitivity of computed diffusion-weighted MR imaging in the detection of breast cancer","volume":"44","author":"O\u2019Flynn","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"R19-20230915","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.acra.2016.11.006","article-title":"Comparison and optimization of 3.0 T breast images quality of diffusion-weighted imaging with multiple B-values","volume":"24","author":"Han","year":"2017","journal-title":"Acad Radiol"},{"key":"R20-20230915","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1186\/1470-7330-14-11","article-title":"Investigation of the optimal b-value to detect breast tumors with diffusion weighted imaging by 1.5-T MRI","volume":"14","author":"Tamura","year":"2014","journal-title":"Cancer Imaging"},{"key":"R21-20230915","doi-asserted-by":"crossref","first-page":"374","DOI":"10.21037\/qims.2016.07.06","article-title":"Effects of magnetic field strength and b value on the sensitivity and specificity of quantitative breast diffusion-weighted MRI","volume":"6","author":"Eghtedari","year":"2016","journal-title":"Quant Imaging Med Surg"},{"key":"R22-20230915","doi-asserted-by":"crossref","first-page":"2835","DOI":"10.1007\/s00330-014-3338-z","article-title":"Effect of b value and pre-admission of contrast on diagnostic accuracy of 1.5-T breast DWI: a systematic review and meta-analysis","volume":"24","author":"Dorrius","year":"2014","journal-title":"Eur Radiol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000017640","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T00:33:33Z","timestamp":1694824413000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000017640"}},"subtitle":["A case\u2013control STROBE compliant study"],"short-title":[],"issued":{"date-parts":[[2019,11]]},"references-count":21,"journal-issue":{"issue":"44","published-online":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000017640","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11]]}}}