{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,21]],"date-time":"2025-06-21T21:22:22Z","timestamp":1750540942397},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"45","license":[{"start":{"date-parts":[[2019,11,1]],"date-time":"2019-11-01T00:00:00Z","timestamp":1572566400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Venous air embolism (VAE) can be observed in the right heart system on contrast-enhanced computed tomography (CT), following injection of contrast media with a power injector system. Although most VAEs are mostly asymptomatic, they may result in paradoxical air embolism (PAE).<\/jats:p>\n            <jats:p>To evaluate whether the incidence of VAE on coronary CT angiography is associated with the process of preparation of the intravenous access route.<\/jats:p>\n            <jats:p>We retrospectively evaluated 692 coronary CT examinations at 3 institutions. Trained CT nurses placed an intravenous cannula in the forearm. Tubes connected to the cannula were prepared in the following ways: A, using an interposed three-way cock and a 20-mL syringe filled with normal saline to collect air contamination in the tube; B, through direct connection to the power injector system without the interposed 3-way cock; and C, using an interposed three-way cock and a 100-mL normal saline drip infusion bottle system to keep the tube patent. The incidence and location of VAE and preparation of intravenous injection were assessed.<\/jats:p>\n            <jats:p>The overall incidence of VAE was 55.3% (383\/692), most frequently observed in the right atrium (81.5%, 312\/383). Its incidence varied significantly across the 3 techniques (A: 21.6% (35\/162), B: 63.2% (237\/375) and C: 71.6% (111\/155); <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001). No patient demonstrated any symptom associated with VAE.<\/jats:p>\n            <jats:p>Using a 3-way cock with syringe demonstrated the lowest incidence of VAE on coronary CT angiography. It is thus recommended to reduce potential complication risks related to intravenous contrast media injection.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000017940","type":"journal-article","created":{"date-parts":[[2019,11,8]],"date-time":"2019-11-08T01:40:07Z","timestamp":1573177207000},"page":"e17940","source":"Crossref","is-referenced-by-count":6,"title":["Association of the incidence of venous air embolism on coronary computed tomography angiography with the intravenous access route preparation process"],"prefix":"10.1097","volume":"98","author":[{"given":"Shingo","family":"Kayano","sequence":"first","affiliation":[{"name":"Department of Radiological Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideki","family":"Ota","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Tohoku University Hospital, Sendai"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayoshi","family":"Yamaguchi","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Hanaoka Seishu Memorial Cardiovascular Clinic, Sapporo, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katsunori","family":"Ono","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kei","family":"Takase","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Tohoku University Hospital, Sendai"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2019,11]]},"reference":[{"key":"R1-20230915","doi-asserted-by":"crossref","first-page":"3","DOI":"10.4102\/sajr.v10i1.186","article-title":"Air embolus revisited - a diagnostic and interventional radiological perspective (bubble trouble and the dynamic Mercedes Benz sign)","volume":"10","author":"Emby","year":"2006","journal-title":"S Afr J Radiol"},{"key":"R2-20230915","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1097\/00004728-199607000-00011","article-title":"Venous air emboli identified on head and neck CT scans","volume":"20","author":"Rubinstein","year":"1996","journal-title":"J Comput Assist Tomogr"},{"key":"R3-20230915","doi-asserted-by":"crossref","first-page":"189","DOI":"10.2214\/ajr.159.1.1609696","article-title":"Iatrogenic air in the cavernous sinus","volume":"159","author":"Adams","year":"1992","journal-title":"AJR Am J Roentgenol"},{"key":"R4-20230915","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1148\/radiology.167.2.3357948","article-title":"Nonfatal venous air embolism after contrast-enhanced CT","volume":"167","author":"Woodring","year":"1988","journal-title":"Radiology"},{"key":"R5-20230915","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.jemermed.2009.11.025","article-title":"Venous air embolism after intravenous contrast administration for computed tomography","volume":"42","author":"Sodhi","year":"2012","journal-title":"J Emerg Med"},{"key":"R6-20230915","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1148\/radiology.202.2.9015074","article-title":"Vascular air embolism: location, frequency, and cause on electron-beam CT studies of the chest","volume":"202","author":"Groell","year":"1997","journal-title":"Radiology"},{"key":"R7-20230915","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1007\/s10554-012-0017-5","article-title":"Paradoxical air embolism following contrast material injection through power injectors in patients with a patent foramen ovale","volume":"28","author":"Yeddula","year":"2012","journal-title":"Int J Cardiovasc Imaging"},{"key":"R8-20230915","doi-asserted-by":"crossref","first-page":"216","DOI":"10.4103\/0970-2113.156216","article-title":"Vascular air embolism after contrast administration on 64 row multiple detector computed tomography: a prospective analysis","volume":"32","author":"Sodhi","year":"2015","journal-title":"Lung India"},{"key":"R9-20230915","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.clinimag.2012.04.001","article-title":"A case of paradoxical air embolism in the coronary artery through a patent foramen ovale demonstrated by coronary CT angiography","volume":"37","author":"Lee","year":"2013","journal-title":"Clin Imaging"},{"key":"R10-20230915","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1097\/00003246-199208000-00017","article-title":"Venous air embolism: clinical and experimental considerations","volume":"20","author":"Orebaugh","year":"1992","journal-title":"Crit Care Med"},{"key":"R11-20230915","first-page":"246","article-title":"Venous air embolism and pressure infusion devices","volume":"63","author":"Mendenhall","year":"2007","journal-title":"J Trauma"},{"key":"R12-20230915","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1001\/jama.1968.03140160077026","article-title":"Lethal air embolism from plastic blood-storage container","volume":"204","author":"Yeakel","year":"1968","journal-title":"JAMA"},{"key":"R13-20230915","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.jamcollsurg.2005.06.276","article-title":"Venous air embolism from intravenous CT contrast administration","volume":"202","author":"Husain","year":"2006","journal-title":"J Am Coll Surg"},{"key":"R14-20230915","doi-asserted-by":"crossref","first-page":"644","DOI":"10.4103\/0970-2113.168124","article-title":"Air in unusual location after contrast-enhanced computed tomography","volume":"32","author":"Gorsi","year":"2015","journal-title":"Lung India"},{"key":"R15-20230915","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0025-6196(12)60336-X","article-title":"Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts","volume":"59","author":"Hagen","year":"1984","journal-title":"Mayo Clin Proc"},{"key":"R16-20230915","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/s10140-003-0270-y","article-title":"Iatrogenic venous air embolism during contrast enhanced computed tomography: a report of two cases","volume":"10","author":"Pham","year":"2003","journal-title":"Emerg Radiol"},{"key":"R17-20230915","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/S0001-2092(07)68353-7","article-title":"Air embolism: a potentially lethal surgical complication","volume":"45","author":"Temple","year":"1987","journal-title":"AORN J"},{"key":"R18-20230915","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1148\/radiology.144.1.7089263","article-title":"Radiographic manifestations of venous air embolism","volume":"144","author":"Kizer","year":"1982","journal-title":"Radiology"},{"key":"R19-20230915","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1097\/00007611-199909000-00019","article-title":"Air embolism after intravenous injection of contrast material","volume":"92","author":"Ie","year":"1999","journal-title":"South Med J"},{"key":"R20-20230915","first-page":"199","article-title":"Large-volume air embolism as a complication of augmented computed tomography: case report","volume":"53","author":"Sheasgreen","year":"2002","journal-title":"Can Assoc Radiol J"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000017940","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T21:51:25Z","timestamp":1694814685000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000017940"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11]]},"references-count":20,"journal-issue":{"issue":"45","published-online":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000017940","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11]]}}}