{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T13:36:55Z","timestamp":1783777015077,"version":"3.55.0"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"47","license":[{"start":{"date-parts":[[2019,11,1]],"date-time":"2019-11-01T00:00:00Z","timestamp":1572566400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Rationale<\/jats:title>\n            <jats:p>: Pipeline embolization device pipeline embolization device (PLED) is one of the most preferred flow-diverting devices used in treating giant and complex intercranial aneurysms. The occurrence of in-stent stenosis (ISS), which is a partially reversible complication, has been associated with PLED. Trauma around the neck of the aneurysm during our attempts to implant the PLED across the aneurysm resulted into inflammatory reactions, endotheliazation, granular tissue formation, and subsequent ISS.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patient concerns:<\/jats:title>\n            <jats:p>We present an 11-year-old girl with dizziness of 6 days duration on account of which she was admitted at our institution. Physical as well as neurological examinations did not yield much.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Diagnoses:<\/jats:title>\n            <jats:p>Cerebral angiography revealed a right cavernous segment giant aneurysm.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Interventions:<\/jats:title>\n            <jats:p>We initially implanted Pipeline embolization devices (PLEDs) (ev3, Irvine, California, USA) across the neck of the aneurysm which resulted into ISS 6 months after the operation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Outcomes:<\/jats:title>\n            <jats:p>We also attempted balloon angioplasty which failed during our second operation. She was finally treated with Neuroform stent (Stryker Neurovascular, USA) with no further complication and two years follow-up revealed no ISS.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Lessons subsections as per style:<\/jats:title>\n            <jats:p>A combination of multiple kinds of flow diverting devices could reduce the incidence of ISS in selected patients with complex aneurysms. Minimal trauma caused by PLED at aneurysm site could also reduce incidence of ISS.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000018092","type":"journal-article","created":{"date-parts":[[2019,11,25]],"date-time":"2019-11-25T06:58:05Z","timestamp":1574665085000},"page":"e18092","source":"Crossref","is-referenced-by-count":7,"title":["Reactive in-stent stenosis of a pipeline embolization device in a child"],"prefix":"10.1097","volume":"98","author":[{"given":"Ting","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, 610041, P. R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chang Wei","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, 610041, P. R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seidu A.","family":"Richard","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, 610041, P. R. China"},{"name":"Department of Medicine, Princefield University, Ho-Volta Region, Ghana, West Africa."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wang","family":"Chaohua","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, 610041, P. R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao Dong","family":"Xie","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, 610041, P. R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,11]]},"reference":[{"key":"R1-20230915","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1136\/neurintsurg-2018-013975","article-title":"Transient in-stent stenosis: a common finding after flow diverter implantation","volume":"11","author":"M\u00fchl-Benninghaus","year":"2019","journal-title":"Journal of Neurointerventional Surgery"},{"key":"R2-20230915","doi-asserted-by":"crossref","first-page":"e35","DOI":"10.1136\/neurintsurg-2014-011384.rep","article-title":"Focal, transient mechanical narrowing of a pipeline embolization device following treatment of an internal carotid artery aneurysm","volume":"7","author":"Miller","year":"2015","journal-title":"Journal of Neurointerventional Surgery"},{"key":"R3-20230915","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.jocn.2013.11.010","article-title":"Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents","volume":"21","author":"Cohen","year":"2014","journal-title":"Journal of Clinical Neuroscience"},{"key":"R4-20230915","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1227\/NEU.0000000000000409","article-title":"Increasing flow diversion for cerebral aneurysm treatment using a single flow diverter","volume":"75","author":"Xiang","year":"2014","journal-title":"Neurosurgery"},{"key":"R5-20230915","doi-asserted-by":"crossref","first-page":"81","DOI":"10.3171\/2015.6.JNS15311","article-title":"Pipeline for uncoilable or failed aneurysms: 3-year follow-up results","volume":"127","author":"Becske","year":"2017","journal-title":"Journal of Neurosurgery"},{"key":"R6-20230915","first-page":"1373","article-title":"Preclinical restenosis models and drug-eluting stents: still important, still much to learn","volume":"44","author":"Schwartz","year":"2004","journal-title":"Journal of the American College of Cardiology"},{"key":"R7-20230915","doi-asserted-by":"crossref","first-page":"2247","DOI":"10.1161\/STROKEAHA.110.589911","article-title":"Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms","volume":"41","author":"Lubicz","year":"2010","journal-title":"Stroke\u2014A Journal of Cerebral Circulation"},{"key":"R8-20230915","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1136\/jnis.2009.000521","article-title":"Neuroform stent assisted aneurysm treatment: evolving treatment strategies, complications and results of long term follow-up","volume":"2","author":"Fiorella","year":"2010","journal-title":"Journal of Neurointerventional Surgery"},{"key":"R9-20230915","doi-asserted-by":"crossref","first-page":"235","DOI":"10.3171\/jns.2005.102.2.0235","article-title":"Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms","volume":"102","author":"Lylyk","year":"2005","journal-title":"Journal of Neurosurgery"},{"key":"R11-20230915","doi-asserted-by":"crossref","first-page":"146","DOI":"10.3171\/jns.2005.103.1.0146","article-title":"Hemodynamic changes due to stent placement in bifurcating intracranial aneurysms","volume":"103","author":"Cant\u00f3n","year":"2005","journal-title":"Journal of Neurosurgery"},{"key":"R12-20230915","doi-asserted-by":"crossref","first-page":"891","DOI":"10.3171\/jns.2005.103.5.0891","article-title":"Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms","volume":"103","author":"Cant\u00f3n","year":"2005","journal-title":"Journal of Neurosurgery"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000018092","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T22:08:45Z","timestamp":1694815725000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000018092"}},"subtitle":["A case report"],"short-title":[],"issued":{"date-parts":[[2019,11]]},"references-count":11,"journal-issue":{"issue":"47","published-online":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000018092","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11]]}}}