{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T16:53:07Z","timestamp":1789663987572,"version":"4.0.1"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"21","license":[{"start":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T00:00:00Z","timestamp":1590105600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Introduction:<\/jats:title>\n            <jats:p>The RF ablation of ventricular tachycardia (VT) or atrial flutter (AFl) can be unsuccessful due to lack of lesion transmurality. Bipolar ablation (BA) is more successful than unipolar ablation (UA). The purpose of our study was to investigate the long-term effect of BA ablation in patients after failed UA.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Patients with septal VT (5) or AFL (2) after 2 to 5 unsuccessful UA were prospectively analysed after BA. All patients presented with heart failure or had ICD interventions.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>BA was successful in 5 patients (1 failure each in the AFL and VT group). The follow-up duration was 10 to 26 months. In AFL group, BA was successful in 1 patient, unidirectional cavotricuspid block in was achieved in the other patient. All patients were asymptomatic for 12 months, but 1 had atrial fibrillation and the other had AFL reablation 19 months after BA. In VT group, all patients had several forms of septal VT. BA was successful in 4 patients. In 2 patients with high septal VT BA resulted in complete atrioventricular block. During follow-up, 1 patient had VT recurrence 26 months after BA and died after an unsuccessful reablation. Three patients had VT recurrences of different morphologies, which required reablation (UA in 2 and alcohol septal ablation in the other patient).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>BA was successful in patients with AFL and septal VT resistant to standard ablation. Relapses of clinical arrhythmia are rare; however, long-term follow-up is complicated by recurrences of different arrhythmias related to complex arrhythmogenic substrate<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000019970","type":"journal-article","created":{"date-parts":[[2020,5,28]],"date-time":"2020-05-28T03:17:28Z","timestamp":1590635848000},"page":"e19970","source":"Crossref","is-referenced-by-count":3,"title":["Long-term results of irrigated bipolar radiofrequency ablation in patients with recurrent arrhythmia after failed unipolar ablation"],"prefix":"10.1097","volume":"99","author":[{"given":"Artur","family":"Baszko","sequence":"first","affiliation":[{"name":"Department of Cardiology, Pozna\u0144 University of Medical Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karol","family":"Kochman","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Pozna\u0144 University of Medical Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomasz","family":"Kr\u00f3lak","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Medical University of Gda\u0144sk, Poland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piotr","family":"Ka\u0142mucki","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Pozna\u0144 University of Medical Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wojciech","family":"Telec","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Pozna\u0144 University of Medical Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"O\u017cegowski","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Pozna\u0144 University of Medical Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrzej","family":"Szyszka","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Pozna\u0144 University of Medical Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,5,22]]},"reference":[{"key":"R1-20240521","doi-asserted-by":"crossref","first-page":"2793","DOI":"10.1093\/eurheartj\/ehv316","article-title":"2015 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the task force for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death of the European Society of Cardiology (ESC)","volume":"36","author":"Priori","year":"2015","journal-title":"Eur Heart J"},{"key":"R2-20240521","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1161\/CIRCEP.111.961946","article-title":"Integration of 3D electroanatomic maps and magnetic resonance scar characterization into the navigation system to guide ventricular tachycardia ablation: clinical perspective","volume":"4","author":"Andreu","year":"2011","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R3-20240521","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1016\/j.hrthm.2011.03.008","article-title":"Isolated septal substrate for ventricular tachycardia in nonischemic dilated cardiomyopathy: incidence, characterization, and implications","volume":"8","author":"Haqqani","year":"2011","journal-title":"Heart Rhythm"},{"key":"R4-20240521","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1161\/CIRCEP.113.001094","article-title":"Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size","volume":"7","author":"Ikeda","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R5-20240521","doi-asserted-by":"crossref","first-page":"e38","DOI":"10.1161\/CIRCEP.111.969345","article-title":"Bipolar ablation of ventricular tachycardia in a patient after atrial switch operation for dextro-transposition of the great arteries","volume":"5","author":"Piers","year":"2012","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R6-20240521","doi-asserted-by":"crossref","first-page":"1721","DOI":"10.1253\/circj.CJ-17-0782","article-title":"Bipolar endo-epicardial radiofrequency ablation of arrhythmia originating from the left ventricular summit","volume":"82","author":"Futyma","year":"2017","journal-title":"Circ J"},{"key":"R7-20240521","doi-asserted-by":"crossref","first-page":"372","DOI":"10.3109\/02656736.2014.949878","article-title":"Radiofrequency cardiac ablation with catheters placed on opposing sides of the ventricular wall: computer modelling comparing bipolar and unipolar modes","volume":"30","author":"Gonz\u00e1lez-Su\u00e1rez","year":"2014","journal-title":"Int J Hyperth"},{"key":"R8-20240521","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1111\/j.1540-8159.2009.02602.x","article-title":"Bipolar ablation of the interventricular septum is more efficient at creating a transmural line than sequential unipolar ablation","volume":"33","author":"Sivagangabalan","year":"2010","journal-title":"PACE"},{"key":"R9-20240521","doi-asserted-by":"crossref","first-page":"1932","DOI":"10.1016\/j.hrthm.2012.08.001","article-title":"Bipolar irrigated radiofrequency ablation: a therapeutic option for refractory intramural atrial and ventricular tachycardia circuits","volume":"9","author":"Koruth","year":"2012","journal-title":"Heart Rhythm"},{"key":"R10-20240521","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.1161\/01.CIR.101.11.1288","article-title":"Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy","volume":"101","author":"Marchlinski","year":"2000","journal-title":"Circulation"},{"key":"R11-20240521","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1016\/j.hrthm.2015.05.036","article-title":"Freedom from recurrent ventricular tachycardia after catheter ablation is associated with improved survival in patients with structural heart disease: an International VT Ablation Center Collaborative Group study","volume":"12","author":"Tung","year":"2015","journal-title":"Heart Rhythm"},{"key":"R12-20240521","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1161\/CIRCEP.113.001239","article-title":"Noninducibility and late potential abolition: a novel combined prognostic procedural end point for catheter ablation of postinfarction ventricular tachycardia","volume":"7","author":"Silberbauer","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R13-20240521","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1111\/jce.12848","article-title":"Value of cardiac magnetic resonance imaging in patients with failed ablation procedures for ventricular tachycardia","volume":"27","author":"Njeim","year":"2016","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R14-20240521","doi-asserted-by":"crossref","first-page":"2161","DOI":"10.1016\/j.hrthm.2016.07.011","article-title":"Clinical and biophysical evaluation of variable bipolar configurations during radiofrequency ablation for treatment of ventricular arrhythmias","volume":"13","author":"Nguyen","year":"2016","journal-title":"Heart Rhythm"},{"key":"R15-20240521","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1111\/j.1540-8159.2006.00533.x","article-title":"RF catheter ablation: lessons on lesions","volume":"29","author":"Wittkampf","year":"2006","journal-title":"Pacing Clin Electrophysiol"},{"key":"R16-20240521","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1253\/circj.CJ-10-0870","article-title":"Lesion formation by ventricular septal ablation with irrigated electrodes: comparison of bipolar and sequential unipolar ablation","volume":"75","author":"Nagashima","year":"2011","journal-title":"Circ J"},{"key":"R17-20240521","first-page":"101","article-title":"Bipolar radiofrequency ablation: the impact of tip load, application duration, power, and indifferent electrode size on the transmurality of a lesion","volume":"1","author":"Baszko","year":"2019","journal-title":"Heart Beat J"},{"key":"R18-20240521","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1002\/ccr3.648","article-title":"Bipolar irrigated radiofrequency ablation of resistant ventricular tachycardia with a septal intramural origin: the initial experience and a description of the method","volume":"4","author":"Baszko","year":"2016","journal-title":"Clin Case Rep"},{"key":"R19-20240521","first-page":"397","article-title":"High-power bipolar ablation for incessant ventricular tachycardia utilizing a deep midmyocardial septal circuit","volume":"1","author":"Sauer","year":"2015","journal-title":"Heart Rhythm Case Rep"},{"key":"R20-20240521","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1093\/europace\/euv441","article-title":"Importance of anatomy in cavotricuspid isthmus","volume":"18","author":"Caldwell","year":"2016","journal-title":"Europace"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000019970","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,21]],"date-time":"2024-05-21T20:00:28Z","timestamp":1716321628000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000019970"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,22]]},"references-count":20,"journal-issue":{"issue":"21","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000019970","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,22]]}}}