{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,3]],"date-time":"2025-08-03T22:57:05Z","timestamp":1754261825315},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"25","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"DOI":"10.1097\/md.0000000000020139","type":"journal-article","created":{"date-parts":[[2020,6,19]],"date-time":"2020-06-19T12:59:09Z","timestamp":1592571549000},"page":"e20139","source":"Crossref","is-referenced-by-count":3,"title":["Using SEMAC at 3 T MR to evaluate spinal metallic implants and peripheral soft tissue lesions"],"prefix":"10.1097","volume":"99","author":[{"given":"Chun","family":"Xin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Houdong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shihong","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guangwu","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,6,19]]},"reference":[{"key":"R1-20210309","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1016\/j.spinee.2006.11.003","article-title":"Clinical outcomes in older patients after posterolateral lumbar fusion","volume":"7","author":"Glassman","year":"2007","journal-title":"Spine J"},{"key":"R2-20210309","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1097\/01.brs.0000158953.57966.c0","article-title":"Long-term outcomes of surgical and nonsurgical management of lumbar spinal stenosis: 8 to 10 year results from the maine lumbar spine study","volume":"30","author":"Atlas","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"key":"R3-20210309","doi-asserted-by":"crossref","first-page":"2089","DOI":"10.2106\/00004623-200311000-00004","article-title":"Perioperative complications of posterior lumbar decompression and arthrodesis in older adults","volume":"85","author":"Carreon","year":"2003","journal-title":"J Bone Joint Surg Am"},{"key":"R4-20210309","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/01.brs.0000192678.25586.e5","article-title":"Predicting morbidity and mortality of lumbar spine arthrodesis in patients in their ninth decade","volume":"31","author":"Raffo","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R5-20210309","doi-asserted-by":"crossref","first-page":"1450","DOI":"10.1097\/BRS.0b013e318060cc88","article-title":"Imaging assessment of lumbar pedicle screw placement: sensitivity and specificity of plain radiographs and computer axial tomography","volume":"32","author":"Brooks","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R6-20210309","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1007\/s00586-012-2505-7","article-title":"Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques","volume":"22","author":"Allam","year":"2013","journal-title":"Eur Spine J"},{"key":"R7-20210309","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1002\/mrm.21967","article-title":"SEMAC: slice encoding for metal artifact correction in MRI","volume":"62","author":"Lu","year":"2009","journal-title":"Magn Reson Med"},{"key":"R8-20210309","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1002\/jmri.20144","article-title":"Quantitative evaluation of metal artifact reduction techniques","volume":"20","author":"Kolind","year":"2004","journal-title":"J Magn Reson Imaging"},{"key":"R9-20210309","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1002\/jmri.23785","article-title":"Artifact reduction from metallic dental materials in T1-weighted spin-echo imaging at 3.0 tesla","volume":"37","author":"Zho","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"R10-20210309","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1118\/1.596162","article-title":"Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting","volume":"15","author":"Cho","year":"1988","journal-title":"Med Phys"},{"key":"R11-20210309","doi-asserted-by":"crossref","first-page":"1352","DOI":"10.1002\/mrm.22796","article-title":"Slice encoding for metal artifact correction with noise reduction","volume":"65","author":"Lu","year":"2011","journal-title":"Magn Reson Med"},{"key":"R12-20210309","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1002\/mrm.24219","article-title":"MR imaging near metal with undersampled 3D radial UTE-MAVRIC sequences","volume":"69","author":"Carl","year":"2013","journal-title":"Magn Reson Med"},{"key":"R13-20210309","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1002\/mrm.22523","article-title":"Imaging near metal with a MAVRIC-SEMAC hybrid","volume":"65","author":"Koch","year":"2011","journal-title":"Magn Reson Med"},{"key":"R14-20210309","doi-asserted-by":"crossref","first-page":"2403","DOI":"10.1007\/s00330-015-3628-0","article-title":"Metal artefact suppression at 3 T MRI: comparison of MAVRIC-SL with conventional fast spin echo sequences in patients with hip joint arthroplasty","volume":"25","author":"Kretzschmar","year":"2015","journal-title":"Eur Radiol"},{"key":"R15-20210309","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/j.mri.2012.11.004","article-title":"Usefulness of slice encoding for metal artifact correction (SEMAC) for reducing metallic artifacts in 3-T MRI","volume":"31","author":"Lee","year":"2013","journal-title":"Magn Reson Imaging"},{"key":"R16-20210309","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1148\/radiol.11101856","article-title":"Reducing metallic artifacts in postoperative spinal imaging: usefulness of IDEAL contrast-enhanced T1- and T2-weighted MR imaging--phantom and clinical studies","volume":"259","author":"Cha","year":"2011","journal-title":"Radiology"},{"key":"R17-20210309","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.clinbiomech.2014.10.003","article-title":"Biomechanical comparison of an interspinous fusion device and bilateral pedicle screw system as additional fixation for lateral lumbar interbody fusion","volume":"30","author":"Doulgeris","year":"2015","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R18-20210309","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/j.mri.2014.04.009","article-title":"Feasibility of fat-saturated T2-weighted magnetic resonance imaging with slice encoding for metal artifact correction (SEMAC) at 3T","volume":"32","author":"Lee","year":"2014","journal-title":"Magn Reson Imaging"},{"key":"R19-20210309","doi-asserted-by":"crossref","first-page":"1570","DOI":"10.1002\/jmri.24729","article-title":"Knee implant imaging at 3 Tesla using high-bandwidth radiofrequency pulses","volume":"41","author":"Bachschmidt","year":"2015","journal-title":"J Magn Reson Imaging"},{"key":"R20-20210309","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1148\/rg.2016150075","article-title":"MR Imaging with metal-suppression sequences for evaluation of total joint arthroplasty","volume":"36","author":"Talbot","year":"2016","journal-title":"Radiographics"},{"key":"R21-20210309","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1002\/mrm.25126","article-title":"Off-resonance suppression for multispectral MR imaging near metallic implants","volume":"73","author":"den Harder","year":"2015","journal-title":"Magn Reson Med"},{"key":"R22-20210309","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1002\/mrm.25127","article-title":"Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction","volume":"73","author":"den Harder","year":"2015","journal-title":"Magn Reson Med"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000020139","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,9]],"date-time":"2021-03-09T05:29:31Z","timestamp":1615267771000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000020139"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,19]]},"references-count":22,"journal-issue":{"issue":"25","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000020139","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,19]]}}}