{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T14:40:41Z","timestamp":1784990441887,"version":"3.55.0"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"27","license":[{"start":{"date-parts":[[2020,7,2]],"date-time":"2020-07-02T00:00:00Z","timestamp":1593648000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"funder":[{"name":"Nature Science Foundation of Hubei Province","award":["2018CFB590"],"award-info":[{"award-number":["2018CFB590"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["NNSFC No. 81470100"],"award-info":[{"award-number":["NNSFC No. 81470100"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Internal fixation such as elastic stable intramedullary(ESIN) nail and submuscular plate (SMP) is gaining popularity for femoral shaft fractures in school-aged children. However, external fixation (ExFix) might be a valuable option for the distal third femoral shaft fractures, where the fracture heals rapidly, but it is crucial to avoid angular malunion. This study aims to compare the clinical outcomes, postoperative complications of distal third femoral shaft fractures in school-aged children treated by ESIN versus ExFix.<\/jats:p>\n            <jats:p>Patients aged 5 to 11 years with distal third femoral shaft fractures treated at our institute from January 2014 to January 2016 were included and categorized into ESIN (n\u200a=\u200a33) and ExFix (n\u200a=\u200a38) group. The preoperative data, including baseline information of the patients, radiographic parameters, and type of surgical procedure, were collected from the hospital database, and postoperative data, including complications, were collected during the follow-up visit.<\/jats:p>\n            <jats:p>In all, 33 patients (average, 8.0\u200a\u00b1\u200a2.1 years, male 20, female 13) in the ESIN group and 38 patients (average, 8.3\u200a\u00b1\u200a2.3 years, male 23, female 15) in the ExFix group were included in this study. There was significantly less operative time for the ExFix group (45.4\u200a\u00b1\u200a7.8\u200amin) as compared to the ESIN group (57.8\u200a\u00b1\u200a11.3\u200amin) (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.01), reduced estimated blood loss (EBL) in the ExFix group (9.9\u200a\u00b1\u200a3.5) as compared to the ESIN group (16.4\u200a\u00b1\u200a6.5) (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.01). As for the frequency of fluoroscopy, there was a significant difference between the ExFix group (13.9\u200a\u00b1\u200a2.4) and the ESIN group (15.5\u200a\u00b1\u200a3.2) (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.02). The rate of major complications was not significantly different between the 2 groups (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.19). The rate of implant irritation was significantly higher in the ExFix group (28\/38, 73.7%) than the ESIN group (12\/33, 36.4%) (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.01). The rate of surgical site infection (SSI) is significantly higher in the ExFix group (18\/38, 47.4%)) than the ESIN group (1\/33, 3%) (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.01). The rate of scar concern was significantly higher in the ExFix (9\/38, 23.7%) than the ESIN (2\/33, 6.1%), (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.04). According to the Flynn scoring system, 30(90.9%) patients in the ESIN group and 24(89.5%) patients in the ExFix group were rated as excellent. None of the patients had poor outcomes.<\/jats:p>\n            <jats:p>Both ESIN and ExFix produced satisfactory outcomes in distal third femoral shaft fractures. ExFix remains a viable choice for selected cases, especially in resource-challenged and austere settings.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000021053","type":"journal-article","created":{"date-parts":[[2020,6,29]],"date-time":"2020-06-29T16:23:29Z","timestamp":1593447809000},"page":"e21053","source":"Crossref","is-referenced-by-count":8,"title":["Distal third femoral shaft fractures in school-aged children"],"prefix":"10.1097","volume":"99","author":[{"given":"Jin","family":"Li","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saroj","family":"Rai","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery, National Trauma Center, National Academy of Medical Sciences, Mahankal, Kathmandu, Nepal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renhao","family":"Ze","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Tang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruikang","family":"Liu","sequence":"additional","affiliation":[{"name":"First School of Clinical Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2674-3016","authenticated-orcid":false,"given":"Pan","family":"Hong","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,7,2]]},"reference":[{"key":"R1-20240214","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1097\/00005373-200211000-00017","article-title":"Femoral shaft fractures in children: traction and casting versus elastic stable intrameduHary nailing","volume":"53","author":"Buechsenschuetz","year":"2002","journal-title":"J Trauma"},{"key":"R2-20240214","first-page":"71","article-title":"Titanium elastic nails for pediatric femur fractures: lessons from the leaming curve","volume":"31","author":"Flynn","year":"2002","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"R3-20240214","first-page":"648","article-title":"Pediatric femoral fractures: a systematic review of 2422 cases","volume":"20","author":"Poolman","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R4-20240214","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1302\/0301-620X.88B10.17517","article-title":"Titanium elastic nailing of fractures of the femur in children. Predictors of complications and poor outcome","volume":"88","author":"Moroz","year":"2006","journal-title":"J Bone Joint Surg Br"},{"key":"R5-20240214","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1097\/BPO.0b013e3181efb89d","article-title":"Decreased complications of pediatric femur fractures with a change in management","volume":"30","author":"Sink","year":"2010","journal-title":"J Pediatr Orthop"},{"key":"R6-20240214","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.2106\/JBJS.G.00328","article-title":"Complications of titanium and stainless steel elastic nail fixation of pediatric femoral fractures","volume":"90","author":"Wall","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"R7-20240214","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1097\/01241398-200101000-00003","article-title":"Titanium elastic nails for pediatric femur fractures: a multicenter study of early results with analysis of complications","volume":"21","author":"Flynn","year":"2001","journal-title":"J Pediatr Orthop"},{"key":"R8-20240214","doi-asserted-by":"crossref","first-page":"596","DOI":"10.5435\/00124635-201209000-00006","article-title":"Submuscular plating of pediatric femur fracture","volume":"20","author":"Li","year":"2012","journal-title":"J Am Acad Orthop Surg"},{"key":"R9-20240214","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1097\/01.bpb.0000111023.13276.43","article-title":"Treatment of femoral shaft fractures in young children: comparison between conservative treatment and retrograde flexible nailing","volume":"13","author":"Song","year":"2004","journal-title":"J Pediatr Orthop B"},{"key":"R10-20240214","doi-asserted-by":"crossref","first-page":"3814","DOI":"10.1007\/s11999-014-3554-5","article-title":"External fixation for closed pediatric femoral shaft fractures: where are we now?","volume":"472","author":"Kong","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"R11-20240214","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.2106\/JBJS.H.01735","article-title":"Femoral fractures in adolescents: a comparison of four methods of fixation","volume":"92","author":"Ramseier","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R12-20240214","first-page":"2797","article-title":"Submuscular bridge plating for complex pediatric femur fractures is reliable","volume":"471","author":"Abdelgawad","year":"2013","journal-title":"Clin O rthop Relat Res"},{"key":"R13-20240214","doi-asserted-by":"crossref","first-page":"353","DOI":"10.3928\/01477447-20160719-03","article-title":"Pediatric diaphyseal femur fractures: submuscular plating compared with intramedullary nailing","volume":"39","author":"Sutphen","year":"2016","journal-title":"Orthopedics"},{"key":"R14-20240214","doi-asserted-by":"crossref","first-page":"526","DOI":"10.2106\/JBJS.K.01190","article-title":"Distal femoral valgus deformity following plate fixation of pediatric femoral shaft fractures","volume":"95","author":"Heyworth","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"R15-20240214","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1097\/BPO.0000000000001301","article-title":"Retrograde stainless steel flexible nails have superior resistance to bending in distal third femoral shaft fractures","volume":"39","author":"Elizabeth","year":"2019","journal-title":"J Pediatr Orthop"},{"key":"R16-20240214","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1097\/01.bot.0000249414.59012.d9","article-title":"Antegrade versus retrograde titanium elastic nail fixation of pediatric distal-third femoral-shaft fractures: a mechanical study","volume":"20","author":"Charles","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R17-20240214","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1097\/01241398-199705000-00014","article-title":"External fixation of pediatric femur fractures","volume":"17","author":"Blasier","year":"1997","journal-title":"J Pediatr Orthop"},{"key":"R18-20240214","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.1016\/j.injury.2003.07.006","article-title":"Technique and considerations when using external fixation as a standard treatment of femoral fractures in children","volume":"35","author":"Hedin","year":"2004","journal-title":"Injury"},{"key":"R19-20240214","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1097\/01241398-200005000-00027","article-title":"Outcomes of external fixation of pediatric femoral shaft fractures","volume":"20","author":"Miner","year":"2000","journal-title":"J Pediatr Orthop"},{"key":"R20-20240214","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1097\/01241398-199909000-00005","article-title":"Secondary fractures associated with external fixation in pediatric femur fractures","volume":"19","author":"Skaggs","year":"1999","journal-title":"J Pediatr Orthop"},{"key":"R21-20240214","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1097\/01241398-199203000-00003","article-title":"External fixation of femur fractures in children","volume":"12","author":"Aronson","year":"1992","journal-title":"J Pediatr Orthop"},{"key":"R22-20240214","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1097\/BOT.0000000000001652","article-title":"Overgrowth of the femur after internal fixation in children with femoral shaft fracture-a multicenter study","volume":"34","author":"Park","year":"2020","journal-title":"J Orthop Trauma"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000021053","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,14]],"date-time":"2024-02-14T16:01:52Z","timestamp":1707926512000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000021053"}},"subtitle":["A comparative study of elastic stable intramedullary nail and external fixator"],"short-title":[],"issued":{"date-parts":[[2020,7,2]]},"references-count":22,"journal-issue":{"issue":"27","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000021053","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,2]]}}}