{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:23:18Z","timestamp":1740144198202,"version":"3.37.3"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"32","license":[{"start":{"date-parts":[[2020,8,7]],"date-time":"2020-08-07T00:00:00Z","timestamp":1596758400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Introduction:<\/jats:title>\n            <jats:p>Pacing of the His bundle and conduction system seems an attractive site for pacing. Lead placement in His-pacing might be technically challenging due to surrounding structures and particular anatomic location.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patient concerns:<\/jats:title>\n            <jats:p>A 62-years old male patient was admitted for recurrent syncope. Electrocardiographic monitoring revealed periods of complete atrioventricular block with left branch block morphology and a QRS duration of 160\u200ams.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Diagnosis:<\/jats:title>\n            <jats:p>A diagnosis of intermittent complete atrioventricular block was made with a Class I indication of permanent dual-chamber cardiac pacing.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Interventions:<\/jats:title>\n            <jats:p>A lead delivery system with a C315 His catheter and a Select Secure 3830 69\u200acm pacing lead was placed at the septal area of the atrioventricular junction with good pacing and sensing thresholds. An important narowing of the QRS was observed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Outcomes:<\/jats:title>\n            <jats:p>After the procedure, good pacing and sensing parameters were observed.<\/jats:p>\n            <jats:p>Echocardiography revealed disappearance of the previously recorded ventricular dyssynchronism.<\/jats:p>\n            <jats:p>Device follow-up at 1 month and 3 months showed stable pacing and sensing parameters.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Pacing the distal His bundle normalized the QRS complex, therefore \u201ccuring\u201d both the atrioventricular and the left bundle branch conduction abnormalities. As such, the technique can be used as an alternative to cardiac electrical resynchronization therapy with acceptable pacing and detection thresholds and better ventricular activation pattern.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000021633","type":"journal-article","created":{"date-parts":[[2020,8,4]],"date-time":"2020-08-04T20:03:10Z","timestamp":1596571390000},"page":"e21633","source":"Crossref","is-referenced-by-count":0,"title":["His bundle pacing \u2013 a curative method"],"prefix":"10.1097","volume":"99","author":[{"given":"Catalin","family":"Pestrea","sequence":"first","affiliation":[{"name":"Department of Interventional Cardiology, Brasov County Emergency Clinical Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexandra","family":"Gherghina","sequence":"additional","affiliation":[{"name":"Department of Interventional Cardiology, Brasov County Emergency Clinical Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Florin","family":"Ortan","sequence":"additional","affiliation":[{"name":"Department of Interventional Cardiology, Brasov County Emergency Clinical Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7352-9584","authenticated-orcid":false,"given":"Gabriel","family":"Cismaru","sequence":"additional","affiliation":[{"name":"5th Department of Internal Medicine, Cardiology-Rehabilitation, \u201cIuliu Hatieganu\u201d University of Medicine and Pharmacy Cluj-Napoca, Romania."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rosu","family":"Radu","sequence":"additional","affiliation":[{"name":"5th Department of Internal Medicine, Cardiology-Rehabilitation, \u201cIuliu Hatieganu\u201d University of Medicine and Pharmacy Cluj-Napoca, Romania."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,8,7]]},"reference":[{"key":"R1-20230915","doi-asserted-by":"crossref","first-page":"e12833","DOI":"10.1097\/MD.0000000000012833","article-title":"Safety and efficacy of AAIR pacing in selected pacing with sick sinus syndrome","volume":"97","author":"Janek","year":"2018","journal-title":"Medicine"},{"key":"R2-20230915","doi-asserted-by":"crossref","first-page":"3099","DOI":"10.1016\/j.jacc.2017.05.005","article-title":"The continued search for physiological pacing: where are we now?","volume":"69","author":"Vijayaraman","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"R3-20230915","doi-asserted-by":"crossref","first-page":"2407","DOI":"10.1161\/CIRCULATIONAHA.112.000112","article-title":"Cardiac resynchronization therapy: state-of-the-art of current applications, guidelines, ongoing trials, and areas of controversy","volume":"128","author":"Prinzen","year":"2013","journal-title":"Circulation"},{"key":"R4-20230915","first-page":"897","article-title":"Outcomes with left bundle branch block and mildly to moderately reduced left ventricular function","volume":"4","author":"Witt","year":"2016","journal-title":"JACC: Heart Failure"},{"key":"R5-20230915","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/0003-4975(94)00878-B","article-title":"Acute hemodynamic effects of atrio-biventricular pacing in humans","volume":"59","author":"Foster","year":"1995","journal-title":"Ann Thorac Surg"},{"key":"R6-20230915","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.1016\/S0735-1097(98)00492-6","article-title":"Acute hemodynamic effects of biventricular DDD pacing in patients with end-stage heart failure","volume":"32","author":"Leclercq","year":"1998","journal-title":"J Am Coll Cardiol"},{"key":"R7-20230915","doi-asserted-by":"crossref","first-page":"2435","DOI":"10.1016\/j.jacc.2013.01.093","article-title":"Noninvasive electrocardiographic mapping to improve patient selection for cardiac resynchronization therapy: beyond QRS duration and left bundle branch block morphology","volume":"61","author":"Ploux","year":"2013","journal-title":"J AmColl Cardiol"},{"key":"R8-20230915","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1056\/NEJMoa1306687","article-title":"Cardiac resynchronization therapy in heart failure with a narrow QRS complex","volume":"369","author":"Ruschitzka","year":"2013","journal-title":"N Engl J Med"},{"key":"R9-20230915","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1161\/01.CIR.57.3.473","article-title":"Normalization of bundle branch block patterns by distal his bundle pacing. clinical and experimental evidence of longitudinal dissociation in the pathologic his bundle","volume":"57","author":"El-Sherif","year":"1978","journal-title":"Circulation"},{"key":"R10-20230915","doi-asserted-by":"crossref","first-page":"1548","DOI":"10.1016\/j.hrthm.2015.03.048","article-title":"His-bundle pacing versus biventricular pacing in cardiac resynchronization therapy patients: a crossover design comparison","volume":"12","author":"Lustgarten","year":"2015","journal-title":"Heart Rhythm Journal"},{"key":"R11-20230915","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.jacc.2019.04.026","article-title":"His corrective pacing or biventricular pacing for cardiac resynchronization in heart failure","volume":"74","author":"Upadhyay","year":"2019","journal-title":"J Am Coll Cardiol Jul"},{"key":"R12-20230915","doi-asserted-by":"crossref","first-page":"1984","DOI":"10.1111\/jce.14064","article-title":"His bundle pacing, learning curve, procedure characteristics, safety and feasibility: insights from a large international observational study","volume":"30","author":"Keene","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R13-20230915","doi-asserted-by":"crossref","first-page":"1876","DOI":"10.1161\/CIRCULATIONAHA.118.038648","article-title":"Intracardiac delineation of septal conduction in left bundle branch block patterns: mechanistic evidence of left intra-hisian block circumvented by his pacing","volume":"139","author":"Upadhyay","year":"2019","journal-title":"Circulation"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000021633","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T00:43:58Z","timestamp":1694825038000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000021633"}},"subtitle":["A Case Report"],"short-title":[],"issued":{"date-parts":[[2020,8,7]]},"references-count":13,"journal-issue":{"issue":"32","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000021633","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2020,8,7]]}}}