{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,7]],"date-time":"2025-04-07T17:47:58Z","timestamp":1744048078242,"version":"3.37.3"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"33","license":[{"start":{"date-parts":[[2020,8,14]],"date-time":"2020-08-14T00:00:00Z","timestamp":1597363200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100009110","name":"Natural Science Foundation of Xinjiang Uygur Autonomous Region","doi-asserted-by":"crossref","award":["2016D01C223"],"award-info":[{"award-number":["2016D01C223"]}],"id":[{"id":"10.13039\/100009110","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Currently, both minimally invasive plate osteosynthesis (MIPO) and intramedullary nailing are the two most commonly used methods of treatment in distal tibial fractures, but controversy still exists regarding the clinical effects of 2 techniques. Our purposes were to compare MIPO and intramedullary nailing for distal tibia shaft fractures by assessing functional outcomes and complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Data were collected retrospectively from the charts of patients treated for distal tibial extra-articular fractures between May 2012 and July 2018. All cases were performed by a single surgeon. Institutional review board approval in the Second Affiliated Hospital of Army Medical University was obtained prior to conducting chart review and analysis. The criteria for inclusion in the study were being aged at least 18 years at the time of diagnosis and having a closed or type I open fracture of the distal third of the tibial diaphysis. The primary outcome compared between the 2 groups was the American Orthopedic Foot and Ankle surgery score. The secondary outcome measures in this trial included Olerud and Molander Ankle Score, radiographic outcomes, and complications. Statistical analysis was performed using SPSS version. <jats:italic toggle=\"yes\">P<\/jats:italic> values\u200a&lt;\u200a.05 were considered statistically significant.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>We hypothesized that MIPO would be associated with better functional outcomes and fewer complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Trial registration:<\/jats:title>\n            <jats:p>This study protocol was registered in Research Registry (researchregistry5808).<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000021779","type":"journal-article","created":{"date-parts":[[2020,8,13]],"date-time":"2020-08-13T06:14:20Z","timestamp":1597299260000},"page":"e21779","source":"Crossref","is-referenced-by-count":7,"title":["Minimally invasive plate osteosynthesis or conventional intramedullary nailing for distal tibial fractures"],"prefix":"10.1097","volume":"99","author":[{"given":"Xin","family":"Song","sequence":"first","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Army Medical University, Chongqing"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xun","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of beauty, Guangzhou Deen Medical Plastic and Aesthetic Hospital, Guangdong"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maihemuti","family":"Yakufu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Sixth Affiliated Hospital of Xinjiang Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bin","family":"Yan","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Seventh Affiliated Hospital of Xinjiang Medical University, Xinjiang, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4527-4235","authenticated-orcid":false,"given":"Chencheng","family":"Feng","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Army Medical University, Chongqing"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,8,14]]},"reference":[{"key":"R1-20230915","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.injury.2010.02.019","article-title":"Distal metadiaphyseal tibial fractures","volume":"42","author":"Newman","year":"2011","journal-title":"Injury"},{"key":"R2-20230915","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1186\/s13018-019-1479-0","article-title":"Minimally invasive percutaneous plate osteosynthesis versus intramedullary nail fixation for distal tibial fractures: a systematic review and meta-analysis","volume":"14","author":"Wang","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"R3-20230915","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1097\/01.ta.0000188936.79798.4e","article-title":"Distal metaphyseal fractures of tibia: a prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation","volume":"59","author":"Im","year":"2005","journal-title":"J Trauma"},{"key":"R4-20230915","first-page":"290","article-title":"Effectiveness of minimally invasive plate osteosynthesis (MIPO) on comminuted tibial or femoral fractures","volume":"5","author":"Andalib","year":"2017","journal-title":"Arch Bone Jt Surg"},{"key":"R5-20230915","doi-asserted-by":"crossref","first-page":"1862","DOI":"10.1016\/j.injury.2016.06.017","article-title":"Minimally invasive plate osteosynthesis using posterolateral approach for distal tibial and tibial shaft fractures","volume":"47","author":"Yamamoto","year":"2016","journal-title":"Injury"},{"key":"R6-20230915","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/00005131-199902000-00004","article-title":"Early outcome of hybrid external fixation for fracture of the distal tibia","volume":"13","author":"Anglen","year":"1999","journal-title":"J Orthop Trauma"},{"key":"R7-20230915","doi-asserted-by":"crossref","first-page":"S96","DOI":"10.1016\/j.injury.2015.10.067","article-title":"Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications","volume":"46","author":"Vidovi\u0107","year":"2015","journal-title":"Injury"},{"key":"R8-20230915","first-page":"243","article-title":"How should open tibia fractures be treated? A retrospective comparative study between intramedullary nailing and biologic plating","volume":"15","author":"Kayali","year":"2009","journal-title":"Ulus Travma Acil Cerrahi Derg"},{"key":"R9-20230915","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/00003086-199706000-00008","article-title":"Nonreamed locking intramedullary nailing for open fractures of the tibia","author":"Bonatus","year":"1997","journal-title":"Clin Orthop Relat Res"},{"key":"R10-20230915","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1007\/s00264-003-0499-9","article-title":"Distal tibial fractures and non-unions treated with shortened intramedullary nail","volume":"27","author":"Megas","year":"2003","journal-title":"Int Orthop"},{"key":"R11-20230915","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1007\/s00264-012-1494-9","article-title":"Comparison of low, multidirectional locked nailing and plating in the treatment of distal tibial metadiaphyseal fractures","volume":"36","author":"Li","year":"2012","journal-title":"Int Orthop"},{"key":"R12-20230915","first-page":"1213","article-title":"Intramedullary nailing of distal metaphyseal tibial fractures","volume":"87","author":"Nork","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"R13-20230915","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.ijsu.2016.12.028","article-title":"Minimally invasive percutaneous plates versus conventional fixation techniques for distal tibial fractures: A meta-analysis","volume":"38","author":"Li","year":"2017","journal-title":"Int J Surg"},{"key":"R14-20230915","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1177\/230949901402200306","article-title":"Minimally invasive plate osteosynthesis for distal tibial fractures","volume":"22","author":"Devkota","year":"2014","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"R15-20230915","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1016\/j.otsr.2010.03.025","article-title":"Minimally invasive locking screw plate fixation of non-articular proximal and distal tibia fractures","volume":"96","author":"Ehlinger","year":"2010","journal-title":"Orthop Traumatol Surg Res"},{"key":"R16-20230915","doi-asserted-by":"crossref","first-page":"537","DOI":"10.5604\/01.3001.0010.8045","article-title":"Operative management of distal tibial extra-articular fractures-intramedullary nail versus minimally invasive percutaneous plate osteosynthesis","volume":"19","author":"Wani","year":"2017","journal-title":"Ortop Traumatol Rehabil"},{"key":"R17-20230915","doi-asserted-by":"crossref","first-page":"292","DOI":"10.4103\/0019-5413.205674","article-title":"A comparative study of intramedullary interlocking nailing and minimally invasive plate osteosynthesis in extra articular distal tibial fractures","volume":"51","author":"Daolagupu","year":"2017","journal-title":"Indian J Orthop"},{"key":"R18-20230915","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1007\/s00776-015-0713-9","article-title":"Intramedullary nailing versus minimally invasive plate osteosynthesis for distal extra-articular tibial fractures: a prospective randomized clinical trial","volume":"20","author":"Polat","year":"2015","journal-title":"J Orthop Sci"},{"key":"R19-20230915","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1097\/BOT.0b013e318213f709","article-title":"Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures","volume":"25","author":"Vallier","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R20-20230915","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1007\/s00402-018-2950-9","article-title":"Clinical and radiological outcome of Gustilo type III open distal tibial and tibial shaft fractures after staged treatment with posterolateral minimally invasive plate osteosynthesis (MIPO) technique","volume":"138","author":"He","year":"2018","journal-title":"Arch Orthop Trauma Surg"},{"key":"R21-20230915","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1051\/sicotj\/2018055","article-title":"Minimally invasive percutaneous plate osteosynthesis versus intramedullary nail fixation for closed distal tibial fractures: a meta-analysis of the clinical outcomes","volume":"4","author":"Goh","year":"2018","journal-title":"SICOT J"},{"key":"R22-20230915","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1302\/0301-620X.94B5.28498","article-title":"A randomised pilot trial of \u201clocking plate\u201d fixation versus intramedullary nailing for extra-articular fractures of the distal tibia","volume":"94","author":"Mauffrey","year":"2012","journal-title":"J Bone Joint Surg Br"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000021779","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T01:17:31Z","timestamp":1694827051000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000021779"}},"subtitle":["A cohort study protocol"],"short-title":[],"issued":{"date-parts":[[2020,8,14]]},"references-count":22,"journal-issue":{"issue":"33","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000021779","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2020,8,14]]}}}