{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:01:32Z","timestamp":1787166092587,"version":"build-2736575974"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2021,1,22]],"date-time":"2021-01-22T00:00:00Z","timestamp":1611273600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"funder":[{"name":"Capital Clinical Application Research and Results Promotion Project","award":["No. Z171100001017154"],"award-info":[{"award-number":["No. Z171100001017154"]}]},{"name":"General Hospital Transformation Project","award":["2017TM-030"],"award-info":[{"award-number":["2017TM-030"]}]},{"name":"General Hospital Clinical Research Supporting Fund","award":["2018FC-304M-TSYS-05"],"award-info":[{"award-number":["2018FC-304M-TSYS-05"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Abstract<\/jats:title>\n                    <jats:p>To study the effect of continuous irrigation of rotating nickel-titanium instrument with several common clinical fluids on the diameter, breaking length and breaking position of nickel-titanium instrument, so as to provide some reference and theoretical basis for clinical operation and instrument improvement.<\/jats:p>\n                    <jats:p>A standardized curved root canal model was established, and ProTaper Universal (PTU) F1 instrument was selected for root canal preparation. The nickel-titanium F1 instrument was flushed with distilled water, 0.9% NaCl, 0.2% chlorhexidine, 1% sodium hypochlorite and 5% sodium hypochlorite, and the diameter, length and position of the instrument before and after breakage were recorded.<\/jats:p>\n                    <jats:p>\n                      Only 5% sodium hypochlorite influenced the diameter of 6\u200amm marker points under different irrigation conditions (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .05). There was no statistical difference in the length of broken instruments among all the groups, and torsional deformation mainly occurred at the end of broken instruments. The broken positions of instruments in all the groups were located at the bending segment of the root canal. The breaking frequency of the 5% sodium hypochlorite group was the highest in the area 3\u20135.5\u200amm away from apical foramen, while the other 4 groups had the highest breaking frequency in the area 0 to 1.5\u200amm away from apical foramen.\n                    <\/jats:p>\n                    <jats:p>External irrigation with different fluids did not influence the breaking length of instruments. The closer to the apical foramen was, the higher the breaking frequency of instruments was. However, only 5% sodium hypochlorite can affect the diameter of rotary nickel-titanium instruments, and may lead to early breakage of the instrument, indicating that the use of disinfectants, except 5% sodium hypochlorite, cannot reduce breakage resistance of nickel-titanium instrument compared with distilled water flushing. Furthermore, 5% hypochlorite could not be recommended for irrigation in clinical practice.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000023865","type":"journal-article","created":{"date-parts":[[2021,1,23]],"date-time":"2021-01-23T08:39:53Z","timestamp":1611391193000},"page":"e23865","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Preventing nickel-titanium rotary instrument from breakage by continuous irrigation with different fluids during root canal preparation"],"prefix":"10.1097","volume":"100","author":[{"given":"Changjian","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Le","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8706-4442","authenticated-orcid":false,"given":"Yanfeng","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haiyun","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiaxin","family":"Bao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiadong","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,1,22]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1016\/j.joen.2006.06.008","article-title":"Rotary NiTi instrument fracture and itsconsequences","volume":"32","author":"Parashos","year":"2006","journal-title":"J Endodont"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.joen.2012.12.033","article-title":"Management of intracanal separated instruments","volume":"39","author":"Madarati","year":"2013","journal-title":"J Endodont"},{"key":"R3-20250504","first-page":"260","article-title":"The effect of the modified root canal preparation method with different liquid continuous flushing on the anti-fracture properties of mechanical nickel-titanium file","volume":"34","author":"Li","year":"2018","journal-title":"J Pract Stomatol"},{"key":"R4-20250504","first-page":"416","article-title":"Establishment of a model of root canal preparation","volume":"34","author":"Xia","year":"2017","journal-title":"Chin J Med Phys"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/j.joen.2011.02.016","article-title":"Removal of broken files from root canals by using ultrasonic techniques combined with dental microscope: a retrospective analysis of treatment outcome","volume":"37","author":"Fu","year":"2011","journal-title":"J Endodont"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1111\/j.1365-2591.2010.01698.x","article-title":"Vertical fracture resistance of roots after ultrasonic removal of fractured instruments[J]","volume":"43","author":"Madarati","year":"2010","journal-title":"Int Endodont J"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.joen.2005.09.014","article-title":"Root canal irrigants","volume":"32","author":"Zehnder","year":"2006","journal-title":"J Endodont"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1016\/j.joen.2011.04.008","article-title":"Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite","volume":"37","author":"Pedull\u00e0","year":"2011","journal-title":"Int Endodont J"},{"key":"R9-20250504","first-page":"225","article-title":"The corrosive effects of sodium hypochlorite on nickel-titanium endodontic instruments: assessment by digital scanning microscope","volume":"58","author":"Cavalleri","year":"2009","journal-title":"Miner Stomatol"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/00004770-200201000-00004","article-title":"Time-dependent effects of EDTA on dentin structures","volume":"28","author":"Calt","year":"2002","journal-title":"J Endodont"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1111\/j.1365-2591.2006.01134.x","article-title":"Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments","volume":"39","author":"Berutti","year":"2006","journal-title":"Int Endodont J"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/00004770-200003000-00008","article-title":"Defects in rotary nickel-titanium files after clinical use","volume":"26","author":"Sattapan","year":"2000","journal-title":"J Endodont"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.joen.2008.10.013","article-title":"Defects in nickel-titanium instruments after clinical use. Part 2: Fractographic analysis of fractured surface in a cohort study","volume":"35","author":"Shen","year":"2009","journal-title":"J Endodont"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1111\/iej.12674","article-title":"Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in a canal with a double curvature","volume":"50","author":"Top\u00e7uo\u011flu","year":"2016","journal-title":"Int Endodont J"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/j.jfma.2016.06.002","article-title":"Cyclic fatigue behavior of nickel-titanium dental rotary files in clinical simulated root canals","volume":"116","author":"Chi","year":"2016","journal-title":"J Formosan Med Assoc"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1111\/iej.12712","article-title":"Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne Gold and Reciproc reciprocating instruments","volume":"50","author":"Elnaghy","year":"2016","journal-title":"Int Endodont J"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"1840","DOI":"10.1016\/j.joen.2016.07.015","article-title":"Evaluation of the cyclic fatigue and torsional resistance of novel nickel-titanium rotary files with various alloy properties","volume":"42","author":"Kaval","year":"2016","journal-title":"J Endodont"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000023865","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T03:00:43Z","timestamp":1746327643000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000023865"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,22]]},"references-count":17,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000023865","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,22]]},"assertion":[{"value":"2020-05-17","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-11-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}