{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T23:23:13Z","timestamp":1791501793869,"version":"4.3.4"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","license":[{"start":{"date-parts":[[2021,3,19]],"date-time":"2021-03-19T00:00:00Z","timestamp":1616112000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>We evaluated the capacity of the XN-350 instrument to analyze 3 different types of body fluid samples under \u201cbody fluid mode.\u201d<\/jats:p>\n            <jats:p>The performance of XN-350 was evaluated in terms of precision, carryover, limit of blank, limit of detection, limit of quantification, and linearity. Cell enumeration and differential data produced by the XN-350 were compared to manual chamber counting results in 63 cerebrospinal fluid (CSF), 51 ascitic fluid, and 51 pleural fluid (PF) samples. Comparisons between XN-350 versus Cytospin data were also performed in PF samples.<\/jats:p>\n            <jats:p>The precision, carry-over, limit of blank, and linearity of the XN-350 were acceptable. The limits of detection for white blood cells (WBCs) and red blood cells were 1.0\/\u03bcL, and 1,000.0\/\u03bcL, respectively; the corresponding limits of quantitation (LOQs) were 5.0\/\u03bcL and 2,000.0\/\u03bcL, respectively. The XN-350's cell enumeration and differential counting correlated well with those of manual chamber counting for all 3 sample types (except for differential counting in CSF samples), particularly parameters involving monocytes (r\u200a=\u200a0.33) and mononuclear cells (MO- body fluid [BF]; r\u200a=\u200a0.26), as well as total cell (TC-BF) enumeration (r\u200a=\u200a0.50) and WBC-BF (r\u200a=\u200a0.50) in PF samples. The MO-BF in CSF samples differed significantly from manual chamber counting results, but neither TC-BF nor WBC-BF in PF samples did. The XN-350 also showed good correlations with Cytospin analyses for differential counting of neutrophils, lymphocytes, and monocytes in PF samples. The differential counting of eosinophils via the XN-350 and Cytospin were not significantly correlated, but the difference between them was not significant.<\/jats:p>\n            <jats:p>The XN-350 is an acceptable alternative to manual fluid analysis. Samples with low cellularity around the LOQ should be checked manually. Moreover, manual differential counting should be performed on CSF samples, particularity those with low cell numbers.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000024852","type":"journal-article","created":{"date-parts":[[2021,3,16]],"date-time":"2021-03-16T21:54:42Z","timestamp":1615931682000},"page":"e24852","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["A comparison of the analysis of 3 types of body fluids using the XN-350 hematology analyzer versus light microscopy assessment"],"prefix":"10.1097","volume":"100","author":[{"given":"Jiwon","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Younggeun","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Han-Sung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hee Jung","family":"Kang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miyoung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Kyung","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,3,19]]},"reference":[{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1515\/cclm-2014-1247","article-title":"Clinical relevance and contemporary methods for counting blood cells in body fluids suspected of inflammatory disease","volume":"53","author":"Fleming","year":"2015","journal-title":"Clin Chem Lab Med"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"568","DOI":"10.7326\/0003-4819-60-4-568","article-title":"Spontaneous peritonitis and bacteremia in Laennec's cirrhosis caused by enteric organisms: a relatively common but rarely recognized syndrome","volume":"60","author":"Conn","year":"1964","journal-title":"Ann Intern Med"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1111\/j.1751-553X.2010.01220.x","article-title":"Performance evaluation of the body fluid mode on the platform Sysmex XE-5000 series automated hematology analyzer","volume":"32","author":"Paris","year":"2010","journal-title":"Int J Lab Hematol"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1111\/ijlh.12723","article-title":"Two-site evaluation of the diagnostic performance of the Sysmex XN Body Fluid (BF) module for cell count and differential in cerebrospinal fluid","volume":"40","author":"Buoro","year":"2018","journal-title":"Int J Lab Hematol"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/0022-510X(94)90159-7","article-title":"A standardized protocol for flow cytometric analysis of cells isolated from cerebrospinal fluid","volume":"121","author":"Dux","year":"1994","journal-title":"J Neurol Sci"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1128\/jcm.23.5.965-966.1986","article-title":"Leukocyte survival in cerebrospinal fluid","volume":"23","author":"Steele","year":"1986","journal-title":"J Clin Microbiol"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1309\/FTT59GWKDWH69FB0","article-title":"Principles of cytocentrifugation","volume":"35","author":"Strokes","year":"2004","journal-title":"Lab Med"},{"key":"R10-20250504","first-page":"606","article-title":"The effects of cytocentrifugation on differential cell counts in samples obtained by bronchoalveolar lavage","volume":"31","author":"Fleury-Feith","year":"1987","journal-title":"Acta Cytol"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.cca.2015.11.005","article-title":"Cell population data and reflex testing rules of cell analysis in pleural and ascitic fluids using body fluid mode on Sysmex XN-9000","volume":"452","author":"Buoro","year":"2016","journal-title":"Clin Chim Acta"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1532\/LH96.04023","article-title":"An evaluation of the utility of performing body fluid counts on the Coulter LH 750","volume":"10","author":"Barnes","year":"2004","journal-title":"Lab Hematol"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1111\/ijlh.12774","article-title":"Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer","volume":"40","author":"Cho","year":"2018","journal-title":"Int J Lab Hematol"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1111\/ijlh.12701","article-title":"Evaluation of the Sysmex XN-550, a novel compact haematology analyser from the XN-L\u00ae series, compared to the XN-20 system","volume":"39","author":"Tailor","year":"2017","journal-title":"Int J Lab Hematol"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1111\/ijlh.12196","article-title":"ICSH guidelines for the verification and performance of automated cell counters for body fluids","volume":"36","author":"Bourner","year":"2014","journal-title":"Int J Lab Hematol"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1515\/CCLM.2010.108","article-title":"Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids","volume":"48","author":"de Jonge","year":"2010","journal-title":"Clin Chem Lab Med"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"49","DOI":"10.11613\/BM.2011.010","article-title":"Comparison of methods: Passing and Bablok regression","volume":"21","author":"Bili\u0107-Zulle","year":"2011","journal-title":"Biochem Med (Zagreb)"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"141","DOI":"10.11613\/BM.2015.015","article-title":"Understanding Bland Altman analysis","volume":"25","author":"Giavarina","year":"2015","journal-title":"Biochem Med (Zagreb)"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1309\/AJCPABGQXSIA4SMT","article-title":"Automated cerebrospinal fluid cell counts using the sysmex XE-5000: is it time for new reference ranges?","volume":"134","author":"Sandhaus","year":"2010","journal-title":"Am J Clin Pathol"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1309\/AJCPSVG4POONQQ1R","article-title":"Comparative evaluation of the Iris iQ200 body fluid module with manual hemacytometer count","volume":"131","author":"Walker","year":"2009","journal-title":"Am J Clin Pathol"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1111\/ijlh.12292","article-title":"Body fluid cellular analysis using the Sysmex XN-2000 automatic hematology analyzer: focusing on malignant samples","volume":"37","author":"Cho","year":"2015","journal-title":"Int J Lab Hematol"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1136\/jcp.44.3.224","article-title":"Monocyte counting: discrepancies in results obtained with different automated instruments","volume":"44","author":"Goossens","year":"1991","journal-title":"J Clin Pathol"},{"key":"R28-20250504","first-page":"32","article-title":"Performance of the Coulter\u00ae GEN S\u2122 system's white cell differential on an abnormal specimen data set","volume":"3","author":"Kessler","year":"1997","journal-title":"Lab Hematol"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"1791","DOI":"10.1515\/cclm-2011-0927","article-title":"Validation of the body fluid module on the new Sysmex XN-1000 for counting blood cells in cerebrospinal fluid and other body fluids","volume":"50","author":"Fleming","year":"2012","journal-title":"Clin Chem Lab Med"},{"key":"R30-20250504","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1016\/j.clinbiochem.2009.01.025","article-title":"Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid","volume":"42","author":"Boer","year":"2009","journal-title":"Clin Biochem"},{"key":"R31-20250504","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.clinbiochem.2013.11.010","article-title":"Automated cerebrospinal fluid cell count--new reference ranges and evaluation of its clinical use in central nervous system infections","volume":"47","author":"Bremell","year":"2014","journal-title":"Clin Biochem"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000024852","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T06:29:08Z","timestamp":1746340148000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000024852"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,19]]},"references-count":24,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000024852","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,19]]},"assertion":[{"value":"2020-06-30","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-01-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}