{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T15:07:39Z","timestamp":1770908859140,"version":"3.50.1"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","license":[{"start":{"date-parts":[[2021,3,26]],"date-time":"2021-03-26T00:00:00Z","timestamp":1616716800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"funder":[{"name":"Anhui provincial department of science and technology","award":["1804h08020247"],"award-info":[{"award-number":["1804h08020247"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>To introduce a novel technique of using individualized 3D printing occipitocervical fusion instrument (3D-OCF) for the treatment of upper cervical deformity with atlantoaxial joint dislocation.<\/jats:p>\n            <jats:p>The surgery for deformity of the craniocervical junction area is a challenge in the field of spine. If the surgical deviation is too large to injure the spinal cord or vertebral artery, it will cause catastrophic damage to the patient. Therefore, it is controversial whether these patients should undergo surgical treatment. We provide a novel surgical approach for the challenging upper cervical surgery through 3D-OCF and a typical patient.<\/jats:p>\n            <jats:p>We present a 54-year-old female patient, who suffered from dizziness and numbness in her limbs for 8\u200amonths. After the patient was admitted, we performed the three-dimensional CT scan, modeled using Mimics software 17.0, and designed customized occipitocervical fusion instrument. Besides, we repeatedly perform simulated surgery based on 3D-printed models before surgery.<\/jats:p>\n            <jats:p>The operative time was 142 minutes and the intraoperative blood loss was 700\u200amL. X-ray showed reduction of atlantoaxial dislocation and accurate position of internal fixation. The patient's symptoms were significantly relieved: the sensation of dizziness and numbness of limbs was obviously relieved, and the sense of banding in chest, abdomen, and ankle was disappeared. At the last follow-up, imaging showed that 3D-OCF had bone-integration and Syringomyelia was disappeared. The patient's cervical JOA (Japanese Orthopaedic Association) score increased from 10 points to 17 points.<\/jats:p>\n            <jats:p>Individualized 3D-OCF can improve the safety and accuracy of upper cervical surgery, reduce the operative time and the number of fluoroscopy. Our study provides a novel surgical approach for the challenging upper cervical surgery.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000025202","type":"journal-article","created":{"date-parts":[[2021,3,23]],"date-time":"2021-03-23T19:24:52Z","timestamp":1616527492000},"page":"e25202","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Surgical treatment for upper cervical deformity with atlantoaxial joint dislocation using individualized 3D printing occipitocervical fusion instrument"],"prefix":"10.1097","volume":"100","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8485-3737","authenticated-orcid":false,"given":"Guoqi","family":"Niu","sequence":"first","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical College, Bengbu"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical College, Bengbu"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lutan","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical College, Bengbu"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gong","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical College, Bengbu"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiankun","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical College, Bengbu"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chao","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical College, Bengbu"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianhao","family":"Dai","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First People's Hospital of Huai Nan City, Huai Nan, Anhui, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hu","family":"Nie","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical College, Bengbu"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianzhong","family":"Bai","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical College, Bengbu"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingquan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical College, Bengbu"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,3,26]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1007\/s00402-013-1755-0","article-title":"A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine","volume":"133","author":"Merc","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1097\/BSD.0b013e31828d6a1b","article-title":"Misplacement pattern of pedicle screws in pediatric patients with spinal deformity: a computed tomography study","volume":"27","author":"Zhu","year":"2014","journal-title":"J Spinal Disord Tech"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"E341","DOI":"10.1097\/BRS.0000000000000772","article-title":"Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system","volume":"40","author":"Kaneyama","year":"2015","journal-title":"Spine (Phila Pa 1976)"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"1738","DOI":"10.1007\/s00586-015-4141-5","article-title":"Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study","volume":"25","author":"Ruatti","year":"2016","journal-title":"Eur Spine J"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"e0171509","DOI":"10.1371\/journal.pone.0171509","article-title":"Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine","volume":"12","author":"Guo","year":"2017","journal-title":"PLoS One"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"015007","DOI":"10.1088\/1748-6041\/10\/1\/015007","article-title":"In vitro fibroblast and pre-osteoblastic cellular responses on laser surface modified Ti-6Al-4\u200aV","volume":"10","author":"Chikarakara","year":"2014","journal-title":"Biomed Mater"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1186\/s12891-018-1928-7","article-title":"Posterior decompression and occipitocervical fixation followed by intraoperative vertebroplasty for metastatic involvement of the axis","volume":"19","author":"Wu","year":"2018","journal-title":"BMC Musculoskelet Disord"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"348","DOI":"10.3171\/2014.5.SPINE121045","article-title":"Outcomes following attempted en bloc resection of cervical chordomas in the C-1 and C-2 region versus the subaxial region: a multiinstitutional experience","volume":"21","author":"Molina","year":"2014","journal-title":"J Neurosurg Spine"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1097\/BRS.0000000000001007","article-title":"An approach to primary tumors of the upper cervical spine with spondylectomy using a combined approach: our experience with 19 cases","volume":"43","author":"Wei","year":"2018","journal-title":"Spine (Phila Pa 1976)"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00007632-199701010-00001","article-title":"Morphometric evaluation of lower cervical pedicle and its projection","volume":"22","author":"Ebraheim","year":"1997","journal-title":"Spine (Phila Pa 1976)"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.wneu.2018.04.069","article-title":"Posterior fossa epidural hematomas: rare but serious complication of occipitocervical fusion surgery","volume":"115","author":"Chang Rong","year":"2018","journal-title":"World neurosurgery"},{"key":"R12-20250504","first-page":"420","article-title":"The prevention and treatment of postoperative complications after cervico-occipital fusion","author":"Hao","year":"2005","journal-title":"Chin J Orthop"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"e0441","DOI":"10.1097\/MD.0000000000010441","article-title":"Revision surgery after rod breakage in a patient with occipitocervical fusion: a case report","volume":"97","author":"Tang","year":"2018","journal-title":"Medicine"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1055\/s-0034-1543967","article-title":"Occipitocervical fusion surgery: review of operative techniques and results","volume":"76","author":"Kukreja","year":"2015","journal-title":"J Neurol Surg B Skull Base"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"1720","DOI":"10.1007\/s00586-014-3354-3","article-title":"The causes and treatment strategies for the postoperative complications of occipitocervical fusion: a 316 cases retrospective analysis","volume":"23","author":"He","year":"2014","journal-title":"Eur Spine J"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"546","DOI":"10.5603\/KP.2014.0119","article-title":"3D heart model printing for preparation of percutaneous structural interventions: description of the technology and case report","volume":"72","author":"Dankowski","year":"2014","journal-title":"Kardiol Pol"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1007\/s10439-016-1676-5","article-title":"3D printed modeling of the mitral valve for catheter-based structural interventions","volume":"45","author":"Vukicevic","year":"2017","journal-title":"Ann Biomed Eng"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"94","DOI":"10.21037\/qims.2018.08.01","article-title":"Design and fabrication of a personalized anthropomorphic phantom using 3D printing and tissue equivalent materials","volume":"9","author":"Zhang","year":"2019","journal-title":"Quant Imaging Med Surg"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.wneu.2017.11.042","article-title":"Design and application of a novel patient-specific three-dimensional printed drill navigational guiding in atlantoaxial pedicle screw placement","volume":"114","author":"Pu","year":"2018","journal-title":"World Neurosurg"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jocn.2019.10.005","article-title":"Patient-specific processes for occipitocervical fixation using biomodelling and additive manufacturing","volume":"71","author":"Thayaparan","year":"2020","journal-title":"J Clin Neurosci"},{"key":"R21-20250504","first-page":"1153","article-title":"Study on the effect of different porosity of 3 D printing porous titanium implants on bone ingrowth","volume":"44","author":"Liu","year":"2019","journal-title":"J Bengbu Med Coll"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"e0214460","DOI":"10.1371\/journal.pone.0214460","article-title":"Design and basic research on accuracy of a novel individualized three-dimensional printed navigation template in atlantoaxial pedicle screw placement","volume":"14","author":"Chen","year":"2019","journal-title":"PLoS One"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000025202","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T06:27:37Z","timestamp":1746340057000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000025202"}},"subtitle":["A case report and literature review"],"short-title":[],"issued":{"date-parts":[[2021,3,26]]},"references-count":22,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000025202","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,26]]},"assertion":[{"value":"2020-11-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-25","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}